ページ1に含まれる内容の要旨
ITE
Indirect calorifi er-solar
ITE - 300/400/500/600/750/1000
Indirect water heater (calorifi er) for solar applications
• Single-wall spiral heat exchanger • PermaGlas Ultra Coat
second-generation glass coating technology prevents corrosion
• ITE 400-1000: Insulated ring base • Insulated access cover for
comprehensive waterside maintenance • Replaceable magnesium
anode • Options: Flexible magnesium anode for installation in
confi ned areas • Powered anode for reduced maintenance
requirem
ページ2に含まれる内容の要旨
ITE Technical specifications Technical data Output coil kW 52 68 72 80 87 2 Surface area coil m 2.45 3.11 3.45 3.72 4.82 Water capacity coil l 14.8 18.8 29.3 31.6 40.9 Flow rate coil (80-60°C) l/h 2236 2924 3096 3440 3741 Pressure drop coil mbar 244 489 104 128 259 Maximum working pressure tank bar 10 10 10 10 10 Maximum working pressure coil bar 16 16 16 16 16 Maximum operating temperature tank °C 95 95 95 95 95 Maximum operating temperature coil °C 110 110 110
ページ3に含まれる内容の要旨
ITE Dimensions ITE 400-1000 2 8 A 1705 2040 1835 2030 2000 D 720 720 910 910 1060 G 255 255 304 305 345 9 7c H 771 915 906 967 947 M 70 70 85 85 95 N 1652 1990 1797 1992 1962 O 115 115 180 180 180 P* 330 330 412 413 447 P** 897 1029 1062 1113 1087 7b R 500 500 649 650 700 S 1096 1288 1236 1297 1397 Ob T 1362 1700 1476 1627 1602 U - - - - - 1 1 1 1 Cold water R2 R2 R2 /2 R2 /2 R2 /2 1 1 1 2 Hot water R2 R2 R2 /2 R2 /2 R2 /2 4 1 1 3 Inlet coil Rp1 Rp1 Rp1 Rp1 /4 Rp1 /4 1 1 4 Outlet c
ページ4に含まれる内容の要旨
ITE Installation diagrams 1 Pressure reducing valve 12 ITE 400-1000 unvented T 3 T&P valve 11 4 Stop valve B 5 Non-return valve 6 Circulation pump 9 Drain valve 14 11 Isolating valve 3 12 Temperature gauge 14 14 Hot water outlets 14 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank F 19 Float valve A Cold water C B Hot water 4 5 6 4 C Return circulation 16 F Primary flow G A G Primary return 15 E Over flow pipe A H Expansion vent pipe 5 1 4 9 A.O