ページ1に含まれる内容の要旨
Positive
Displacement Pump
Models PD3, 5, 7.5, 10, 15 and 25
Installation
Maintenance
Operation
Troubleshooting
The Conair Group, Inc.
Instant Access
One Conair Drive
Parts and Service
Pittsburgh, PA 15202
(800) 458-1960
Phone: (412) 312-6000
(814) 437-6861
Fax: (412)-312-6320
www.conairnet.com
IMB036/0898
ページ2に含まれる内容の要旨
It’s a good idea to record the model and serial number(s) of Please record your your equipment and the date you received it in the User equipment’s model and Guide. Our service department uses this information, along serial number(s) and with the manual number, to provide help for the specific the date you received it equipment you installed. Please keep this User Guide and all manuals, engineering prints and parts lists together for documentation of your equipment. Date: Manual Number: IMB036/0
ページ3に含まれる内容の要旨
INTRODUCTION TABLE OF ATTENTION: Read this first so no one gets hurt . . . . . . . . .1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 CONTENTS Optional Sound Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . .2 SPECIFICATIONS Positive displacement pump . . . . . . . . . . . . . . . . . . . . . . . . .3 Pumps with sound enclosures . . . . . . . . . . . . . . . . . . . . . . . .3 INSTALLATION Installing the pump . . . . . . . . . . . . . . . .
ページ4に含まれる内容の要旨
We design equipment with the user’s safety in mind. You can ATTENTION: avoid the potential hazards identified on this machine by following the procedures outlined below and elsewhere in READ THIS SO NO the User Guide. ONE GETS HURT WARNING: Improper installation, operation or servicing may result in equipment damage or personal injury. This equipment should be installed, adjusted, and serviced by qualified technical personnel who are familiar with the construction, opera- tion and potential ha
ページ5に含まれる内容の要旨
Conair positive displacement vacuum pumps are designed for DESCRIPTION long distance, high-volume material conveying applications. Each model employs a powerful, rotating lobe-type blower, protected by a vacuum relief valve (factory-set to 12 in. Hg) and belt driven by a three-phase motor with magnetic starter and overload protection. An integrated pump protection filter is included and all components are mounted on a rugged frame, housing an integrated exhaust muffler. An optional sound enclosu
ページ6に含まれる内容の要旨
SPECIFICATIONS: POSITIVE DISPLACEMENT PUMP Vacuum Inlet H Exhaust D W MODEL PD3 PD5 PD7.5 PD10 PD15 PD25 Motor Type* TEFC TEFC TEFC ODP ODP ODP Performance characteristics Horsepower 3 5 7.5 10 15 25 Standard CFM at material pickup point @ 10" Hg 52.6 76.6 121.2 154.5 201.1 346.2 Average sound level (dbA) @ 8", 10" and 12" Hg 86 86.3 86 85.8 88.8 93 Dimensions / in. {mm} Standard inlet line size (OD) 1.5 {38} 1.75 {44} 2.25 {57} 2.5 {64} 3.0 {76} 4.0 {102} Exhaust line size (OD) 2.5 {64} 2.5 {
ページ7に含まれる内容の要旨
Set or mount the vacuum pump in any convenient location. INSTALLING Refer to the accompanying wiring diagram for connection of THE PUMP the main power supply and the conveying control circuit.You must provide a wall-mounted disconnect for three-phase elec- trical connection. Incoming voltage and current must match the electrical specifications on the pump data plate and serial tag. Check for proper rotation of the pump after power has been connected and before operation. Install vacuum lines to
ページ8に含まれる内容の要旨
To maintain the best performance, you should follow the PREVENTATIVE maintenance recommendations outlined here and in any included manuals from component manufacturers. MAINTENANCE l Weekly, or as often as needed SCHEDULE r Check and clean the pump inlet filter. An inlet filter has been provided to protect the pump from solid material that can enter and damage the pump impellers. material can enter the vacuum line if a loader filter is improperly installed or if if has a hole in it. Replace t
ページ9に含まれる内容の要旨
Conair has made the largest investment in customer support in WE’RE HERE the plastics industry. Our service experts are available to help with any problem you might have installing and operating TO HELP your equipment. Your Conair sales representative also can help analyze the nature of your problem, assuring that it did not result from misapplication or improper use. To contact Customer Service personnel, call: HOW TO CONTACT CUSTOMER From outside the United States, call: 814-437-6861 SERVICE Y
ページ10に含まれる内容の要旨
Conair guarantees the machinery and equipment on this order, EQUIPMENT for a period as defined in the quotation from date of shipment, against defects in material and workmanship under the normal GUARANTEE use and service for which it was recommended (except for parts that are typically replaced after normal usage, such as filters, liner plates, etc.). Conair’s guarantee is limited to replacing, at our option, the part or parts determined by us to be defective after examination. The customer ass