USER’S INFORMATION MANUAL
HEAT PUMPS with
Puron® Refrigerant
Single Speed,
Two-Speed
NOTE TO
INSTALLER:
This manual
must be
left with the
equipment user.
O
W
T
•
ページ2に含まれる内容の要旨
Do Not Block Registers WELCOME TO • ! WARNING Supply-air and return-air registers should EFFICIENT YEAR- not be blocked. Drapes, furniture, and To prevent personal injury, ROUND COMFORT toys are some of the items commonly death, or property damage, found obstructing registers. Restricted Congratulations on your excellent choice read and follow all instructions airflow lessens the unit’s efficiency and and sound investment in year-round and warnings, inclu
ページ3に含まれる内容の要旨
LCD READOUT DISPLAYS CURRENT ROOM TEMPERATURE, DESIRED ROOM TEMPERATURE, UNIT MODE SETTING, AND FAN MODE SETTING Thermostat UP AND DOWN BUTTONS INCREASE OR DECREASE THE DESIRED TEMPERATURE RESET/FILTER FAN MODE SETTINGS MODE BUTTON SELECTS BETWEEN OFF, HEAT, COOL, AUTO, AND EMERGENCY HEAT OPERATION RESET FILTER BUTTON FAN BUTTON CHOOSES RESTARTS THE TIMER BETWEEN ON OR AUTO THAT CALCULATES FAN OPERATION THE NEXT AIR FILTER CHANGE OR CLEANING Fig. 2—Bryant Non-Programmable Therm
ページ4に含まれる内容の要旨
Don’t Worry About Ice to AUTO, cooling mode is activated If you wish to program your accessory • On Your Unit when the indoor temperature rises above electronic indoor thermostat, please refer Ice or frost will tend to form on the the thermostat cooling temperature set- to thermostat Owner’s Manual. outdoor coil during the winter heating ting, or heating mode is activated when operation. Your heat pump is designed to the indoor temperature drops below the COOLING CYCLE automa
ページ5に含まれる内容の要旨
equipped with a supplemental heating it is necessary. Your Bryant programmable ! CAUTION source such as electric, gas, or oil. On electronic thermostat has a service alarm cold days and nights, your system will indicator. In the heating season, if the ther- Although special care has been automatically turn on the supplemental mostat ever displays the TROUBLE mes- taken to minimize sharp edges in heat in order to maintain the level of sage, switch your thermostat to EHEAT the
ページ6に含まれる内容の要旨
require the removal of the coil. unit is no longer level, you should by a properly trained service technician. DO NOT attempt this yourself. correct the condition. Relevel it The inspection (preferably twice each promptly to assure that water drains out year, but at least once every year) should of the unit. If you notice that water or include the following: ice collects beneath the unit, arrange • Routine inspection of air filter(s). for it to be drained away from the Re
ページ7に含まれる内容の要旨
7
ページ8に含まれる内容の要旨
INSTALLATION DATA Date Installed MODULAR INDOOR UNIT, if Applicable: Dealer Name Blower—Product No. Address Model No. City Serial No. State Zip Telephone Coil—Product No. Model No. SPLIT-SYSTEM Serial No. OUTDOOR UNIT: Product No. Heater—Product No. Model No. Model No. Serial No. Serial No. INDOOR UNIT OR COIL: ACCESSORIES Product No. Product No. Model No. Product No. Serial No. Product No. Product No. Product No. Cancels: OM02-18/OM02-21 OM02-22 © 2001 Bryant Heating