ページ1に含まれる内容の要旨
READ AND SAVE THESE INSTRUCTIONS
CF711 shown
Model No.
Model No.
CF710AB00
CF711AB00 CF711BS00
CF710WW00
CF711WW00 CF711WB00
CF710PB00
CF711PB00 CF711CK00
CF710AW00
CF711AW00
CF710BS00
Net Weight: 15.0 Lbs. Net Weight: 19.8 Lbs.
®
BUILDER PLUS Series
Ceiling Fan Owner's Manual
Part No. F40BP72580002 Form No. BP7258-2
ページ2に含まれる内容の要旨
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
ページ3に含まれる内容の要旨
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder Installed Wire Length Wire Size A.W.G. One 1/4” blade screwdriver One wire stripper Up to 50 ft. 14 Three wire connectors (supplied). 50-100 ft. 12 MATERIALS WARNING ! Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would Before assembling your ceiling fan
ページ4に含まれる内容の要旨
HANGER BALL/DOWNROD IMPORTANT DECORATIVE ASSEMBLY CAP Your ceiling fan is designed to be installed CEILING either in the standard manner, or in the HAIRPIN COVER close-to-the-ceiling manner. Using the CLIP SETSCREW standard method, the hanger ball/downrod assembly will suspend the fan several inches CLEVIS below the ceiling cover. Using the PIN close-to-the-ceiling method, the ceiling cover MOTOR COUPLING installs directly on the fan motor housing, thus mounting the fan 3-1/2 inches closer to
ページ5に含まれる内容の要旨
NOTE: The hanger bracket must be mounted Installing The flush with the ceiling in order for the ceiling cover to install properly. If necessary, use leveling Hanger Bracket washers (not supplied) between the outlet box and the hanger bracket. ! WARNING 2. Slide the hanger bracket onto the outlet box screws. Center the bracket over the outlet box and The fan must be hung with at least 7' of clearance then securely tighten the screws (Figure 6). from floor to blades (Figure 4). ! WARNING Hanger b
ページ6に含まれる内容の要旨
Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. ! WARNING HANGER BRACKET HOOK To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for TAB Fan Support”, and use screws supplied with outlet box. HANGER GROOVE BALL Most outlet boxes commonly used for support of l
ページ7に含まれる内容の要旨
2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector INSTALL SCREW AND WASHER TIGHTEN SCREW supplied (Figure 9). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 9). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the LOOSEN THIS ot
ページ8に含まれる内容の要旨
2. Mount one blade assembly to the motor hub by Removal Of The mating the alignment post (Figure 11) of the flange with one of the alignment slots in the motor hub Light Fixture (Figure 12). Then tighten the two captive screws in the flange to secure the flange to the motor hub. NOTE: In some instances it may be desirable to Repeat this procedure for the other four blade install the ceiling fan without the light fixture. If assemblies. Make sure all screws are tightened. this is the case, procee
ページ9に含まれる内容の要旨
Using Your Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. SPEED CONTROL 2. Check the operation of the light by gently pulling on PULL CHAIN SWITCH the light switch pull chain. REVERSING SWITCH 3. Check the operation of the fan by gently pulling on the speed control switch pull chain. The operation sequence is as follows: 1st pull - High 3rd pull - Low LIGHT PULL CHAIN SWITCH 2nd pull - Medium 4th pull - OFF 4. Your fan is shipped fro
ページ10に含まれる内容の要旨
Maintenance Accessories 1. Ceiling Fan/Light Controls (see store or catalog). IMPORTANT CARE INSTRUCTIONS 2. Downrod Extension Kits (see store or catalog). for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only ! WARNING maintenance that is needed. The use of any other control not specifically When cleaning, use only a soft brush or lint free cloth approved for this fan could result in fire, shock and to avoid scratching the finish. personal injury. Abrasive cleaning agents a
ページ11に含まれる内容の要旨
Repair Parts 1 2 3 9 17 10 11 16 15 4 8 5 6 7 12 14 13 13 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545. 11
ページ12に含まれる内容の要旨
Repair Parts Listing Model No. Key No. Description CF711AB00 CF711WW00 CF711AW00 CF711PB00 CF711BS00 CF711WB00 CF711CK00 * Hanger Pack Assembly, 762231 762231-1 762231-2 762231-3 762231-4 762231-5 762231-6 Consisting of: 1 Hanger Bracket — — — — — — — 2 Hanger Ball/ Downrod Assembly — — — — — — — 3 Ceiling Canopy 762218 762218-1 762218-2 762218-3 762218-4 762218-5 762218-6 4 Light Fixture 762224 762224-1 762224-2 762224-3 762224-4 762224-5 762224-6 5 Glass Shade (1) 762221 762221-1 762221-1 7622