Features and Benefits • CLIMATUFF® compressor • P olyslate g r a y cabinet with • Efficiency up to 16.0 SEER anthr acite g r a y badge and cap • All alumin um SPINE FIN ™ coil • High pressure s witch • WEATHERGUARD ™ f asteners • Ser vice v alv e co v er • QUICK-SESS ™ cabinet, • R-410A refr iger ant ser vice access and refr iger ant • S .E.E.T . design testing connections with full coil • 100% line r un test protection • Lo w ambient cooling to 30°F with • DURATUFF ™
ページ3に含まれる内容の要旨
Features and Benefits 2 General Data 4 Product Specifications 4 A-W eighted Sound P o w er Le v el [dB(A)] 4 Accessor y Descr iption and Usage 6 AHRI Standard Capacity Rating Conditions 6 Model Nomenclature 7 Electrical Data 8 Dimensions 13 Mechanical Specification Options 16 22-1833-09 3
ページ4に含まれる内容の要旨
General Data Product Specifications Model No. 1 4TTB4018E1 4TTB4024E1 4TTB4030E1 4TTB4036E1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 9 9 12 19 Max Fuse Size (Amps) 15 15 20 30 ® ® ® ® - Compressors CLIMATUFF CLIMATUFF CLIMATUFF CLIMATUFF SCROLL No. Used - No. Stages 1-1 1-1 1-1 1-1 RL AMPS - LR AMPS 6.4 - 38.6 6.8 - 38.6 9.1 - 57.8 14.1 - 77 Outdoor Fan FL Amps 0.74 0.74 0.93 0.93 Fan HP 1/8 1/8 1/5 1/5 Fan Dia (inches) 23 23 27.6 27.6 Coil
ページ5に含まれる内容の要旨
General Data Product Specifications Model No. 1 4TTB4042E1 4TTB4048E1 4TTB4049E1 4TTB4060E1 4TTB4061E1 Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 230/1/60 Min Cir Ampacity 23 26 26 34 45 Max Fuse Size (Amps) 40 45 45 60 60 ® - ® - ® - ® - ® - Compressors CLIMATUFF SCROLL CLIMATUFF SCROLL CLIMATUFF SCROLL CLIMATUFF SCROLL CLIMATUFF SCROLL No. Used - No. Stages 1-1 1-1 1-1 1-1 1-2 RL AMPS - LR AMPS 17.9 - 112 19.9 - 109 19.9 - 109 26.4 - 134 32.1 - 152.9 Ou
ページ6に含まれる内容の要旨
General Data Accessor y Descr iption and Usage AHRI Standard Capacity Rating Conditions Anti-Short Cycle Timer — Solid state timing de vice that AHRI STANDARD 210/240 RATING CONDITIONS — pre v ents compressor recycling until 5 min utes ha v e elapsed (A) Cooling 80°F DB , 67°F WB air enter ing indoor coil, after satisfying call or po w er interr uptions . Use in area with 95°F DB air enter ing outdoor coil. questionab le po w er deliv er y , commercial
ページ7に含まれる内容の要旨
Model Nomenclature TU D2 B0 80 AC V3 2 AA 4T TB 40 36 E1 000 AA Gas Furnaces Outdoor Units Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230
ページ8に含まれる内容の要旨
Electrical Data Schematic Diagrams 4TTB4018, 4TTB4024, 4TTB4030 F rom Dr a wing D157123P01REV0 8 22-1833-09
ページ9に含まれる内容の要旨
Electrical Data Schematic Diagrams 4TTB4036, 4TTB4042 F rom Dr a wing D157124P01 22-1833-09 9
ページ10に含まれる内容の要旨
Electrical Data Schematic Diagrams 4TTB4048, 4TTB4049 F rom Dr a wing D157125P01 10 22-1833-09
ページ11に含まれる内容の要旨
Electrical Data Schematic Diagrams 4TTB4060 F rom Dr a wing D157126P01 22-1833-09 11
ページ12に含まれる内容の要旨
Electrical Data Schematic Diagrams 4TTB4061 F rom Dr a wing D156975p01 12 22-1833-09
ページ13に含まれる内容の要旨
Dimensions 4TTB4 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE A B C D E F G H J K 4TTB4018E 3 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 127 (5) 76 (3) 197 (7-3/4) 57 (2-1/4) 508 (20) 4TTB4024E 3 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 3/4 3/8 127 (5) 76 (3) 197 (7-3/4) 57 (2-1/4) 508 (20) 4TTB4030E 4 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TTB4036E 4 943 (37-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/
ページ14に含まれる内容の要旨
Notes 14 22-1833-09
ページ15に含まれる内容の要旨
Notes 22-1833-09 15
ページ16に含まれる内容の要旨
Mechanical Specification Options General Condenser Coil The 4TTB4 is fully charged from the The outdoor coil pro vides lo w airflo w f actor y f or up to 15 f eet of piping. This resistance and efficient heat tr ansf er . unit is designed to oper ate at outdoor The coil is protected on all f our sides b y ambient temper atures as high as 115°F . louv ered panels . Cooling capacities are matched with Low Ambient Cooling a wide selection