ページ1に含まれる内容の要旨
READ AND SAVE THESE INSTRUCTIONS
™
CARRERA GRANDE
Ceiling Fan Owner's Manual
Model Numbers
CF787AW00 - Summer White
CF787AP00 - Antique Pewter
CF787BS00 - Brushed Steel
CF787GBZ00 - Gilded Bronze
CF787GES00 - Golden Espresso
CF787ORB00 - Oil Rubbed Bronze
54”, 60” or 72” Fan Blades
Net Weight: 25.3 Lbs.
Not Included
Part No. F40BP73770001 Form No. BP7377-1
U.L. Model No.: CF787
ページ2に含まれる内容の要旨
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
ページ3に含まれる内容の要旨
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One wire stripper Three wire connectors (supplied) ! WARNING MATERIALS Before assembly your ceiling fan, refer to section on Wiring outlet box and box connectors must be of type proper method of wiring your fan (page 7). If you feel requ
ページ4に含まれる内容の要旨
Electrical Requirements Your new ceiling fan will require a grounded electrical ! WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid capable of withstanding a load of at least 50 pounds. possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and ! WARNING Local codes and the ceiling fan must be properly
ページ5に含まれる内容の要旨
4. The blade flanges have an interlocking feature that 6. Position the switch housing assembly on the must be fully engaged before tightening the screw. switch housing plate and align the holes in the Make sure all the flanges are properly engaged switch housing assembly with the holes in the and then tighten the flange screws. If one of the plate. Secure the switch housing assembly by flanges does not seat properly on the motor hub, installing the three M4 x 12mm flat head screws loosen the adj
ページ6に含まれる内容の要旨
NOTE: The setscrews must be properly installed 11. Reinstall the hanger ball (Figure 9) on the as described above, or fan wobble could result. downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align ! WARNING the hanger ball so the pin is captured in the It is critical that the clevis pin in the motor coupling groove in the top of the hanger ball. Pull the is properly installed and the setscrews securely hanger
ページ7に含まれる内容の要旨
How to Hang Your Ceiling Fan 2. Carefully lift the fan and seat the hanger ! WARNING ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 12). Be The fan must be hung with at least 7' of clearance sure the groove in the ball is lined up with tab on from floor to blades (Figure 10). the hanger bracket (Figure 11). CEILING ! WARNING Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until AT LEAST bracket con
ページ8に含まれる内容の要旨
How to Wire Your Ceiling Fan If you feel that you do not have enough electrical ! WARNING wiring knowledge or experience, have your fan installed by a licensed electrician. Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not ! WARNING operate fan until blades are in place. Noise and fan To avoid possible electrical shock, be sure electricity damage could result. is turned off at the main fuse b
ページ9に含まれる内容の要旨
Using Your Ceiling Fan Maintenance 1. Restore electrical power to the outlet box by turning IMPORTANT CARE INSTRUCTIONS the electricity on at the main fuse box. for your Ceiling Fan 2. Check the operation of the fan by gently pulling on Periodic cleaning of your new ceiling fan is the only the pull chain switch. maintenance that is needed. 3. All fans are shipped from the factory with the When cleaning, use only a soft brush or lint free cloth reversing switch positioned “down” to circulate air
ページ10に含まれる内容の要旨
Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on comfortable breeze, lower speeds consume less energy. In the proper installation and use of the ceiling fan. Here are a the winter, reverse the motor and operate the ceiling fan at few tips to ensure quality and product performance. low speed in the clockwise direction. This produces a gentle updraft, which forces warm air near the ceiling down Choosing the Appropriate Mounting Location. Ceiling into
ページ11に含まれる内容の要旨
Repair Parts Listing Model No. Key No. Description CF787AW00 CF787BS00 CF787GBZ00 CF787GES00 CF787ORB00 CF787AP00 * Hanger Ball Assembly, 761655-21 761655-17 761655-77 761655-35 761655-32 761655-34 Consisting of: 1 Hanger Bracket — — — — — — 2 Hanger Ball — — — — — — 3 Downrod (12”) — — — — — — * Parts Bag Containing: 763796-1 763796-1 763796-2 763796 763796 763796 4 Wire Connector (3) — — — — — — 5 Pin, Clevis — — — — — — 6 Clip, Hairpin — — — — — — 7 Screw, Flat Head M4 x 12mm (1) — — — — — —
ページ12に含まれる内容の要旨
LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your