ページ1に含まれる内容の要旨
READ AND SAVE THESE INSTRUCTIONS
™
LUXE ECO
54” Ceiling Fan Owner's Manual
Model Number
CF550BS00
CF550ORB00
Net Weight: 20.9 Lbs.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label.
You should record this data above and keep it in a safe place for future use.
Part No. F40BP74530001 Form No. BP7453-1
ETL Model No.: CF550
ページ2に含まれる内容の要旨
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
ページ3に含まれる内容の要旨
Unpacking Instructions 2. Remove the lower styrofoam pad from the carton WARNING ! and place on a stable work surface. Do not install or use fan if any part is damaged or 3. Remove the fan motor assembly from the missing. Call Toll-Free: protective plastic bag and position the fan motor assembly in the lower styrofoam packing so that 1-800-654-3545 the top for the motor is facing you. Place all carton contents on a soft protective surface. WARNING ! This product is designed to use only those par
ページ4に含まれる内容の要旨
Electrical Requirements Your new ceiling fan will require a grounded electrical ! WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is capable of withstanding a load of at least 50 pounds. turned off at the main fuse box before wiring. All wiring must be in accordance with National and ! Local codes and the ceiling fan must be properly WARNING
ページ5に含まれる内容の要旨
How to Put Your Ceiling Fan Together (continued) 4. Make sure the rubber grommet is properly installed onto the coupling cover then slide the coupler cover onto the downrod until it rests on top of the motor housing. Place the ceiling cover over the downrod. Be sure both the ceiling cover and CEILING COVER the coupler cover are oriented correctly (Figure 3). 5. Route the motor leads through the hanger ball. Reinstall the hanger ball (Figure 4) on the DOWNROD downrod. Reinstall the pin through t
ページ6に含まれる内容の要旨
How to Hang Your Ceiling Fan CEILING ! WARNING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. AT LEAST 7' ! WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 6). FLOOR Figure 6 ! WARNING The outlet bo
ページ7に含まれる内容の要旨
How to Wire Your Ceiling Fan If you feel that you do not have enough electrical BLACK wiring knowledge or experience, have your fan FAN WIRE GROUND installed by a licensed electrician. WIRE LISTED WHITE SUPPLY WIRE ! WARNING (NEUTRAL) CONNECTOR (3) Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and GREEN WIRE Local codes and the ceiling fan must be
ページ8に含まれる内容の要旨
Lower Light Kit Assembly 1. With the fan assembly safely installed on the mounting bracket, install the lower light kit as MOTOR HOUSING ASSEMBLY follows. MOTOR HOUSING BLACK WIRE 2. Remove one screw (retain for future use) and loosen the two other screws in the motor housing LOOSEN TWO SCREWS for installation of the light kit assembly (Figure 11). 3. Connect the white wire from the ceiling fan assembly to the white wire of the light kit assembly WIRE CONNECTORS (Figure 11). Connect the black
ページ9に含まれる内容の要旨
LOAD BLACK Wall Control Procedures General Preset Memory Feature Your Emerson Ceiling Fan/Light Control consists of Your Emerson receiver is equipped with a preset wall mounted transmitter and a receiver which is pre- memory feature. If the AC supply to the receiver is installed inside the motor assembly. The remote powered through a wall switch, when the switch is control is designed to separately control your ceiling turned OFF, the control will remember the light fan speed and light intensity
ページ10に含まれる内容の要旨
T T O O 1 2 0 V A C L S O O Wall Control Installation (continued) NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all FAN/LIGHT WALL SCREWS (2) CONTROL WALL BOX connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. U 1. Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan wall control into the outlet box. !
ページ11に含まれる内容の要旨
BLACK BLACK Wall Control Installation (continued) ! WARNING STANDARD WIRING FOR EXISTING 3-WAY CONTROLS Check to see that all connections are tight and that no bare wires are visible at the wire connectors. EXISTING WALL CONTROL 6. Screw wall control into wall box using the supplied HOT BLK screws. Leave wall control in “OFF” mode until fan installation is completed. 7. The wall control is supplied with a white, ivory, and almond color switch covers. Choose the finish that TRAVELER WIRES best
ページ12に含まれる内容の要旨
Programming the Receiver Operating Frequency & High Speed Conditioning of Fan Control IMPORTANT: Ceiling fan blades MUST be IMPORTANT: Do not interrupt the installed before high speed conditioning conditioning until the fan comes to a can begin. complete stop in approximately 5 minutes. All functions of the control will be rejected 1. Within 1 minute of restoring electricity to the ceiling fan, push and hold the fan OFF button ( ) during conditioning. for 3 to 5 seconds to set the code in the
ページ13に含まれる内容の要旨
Accessories 1. Ceiling Fan/Light Controls (see store or catalog). ! WARNING 2. Downrod Extension Kits (see store or catalog). This product is designed to use only those parts supplied with this product and/or any accessories ! WARNING designated specifically for use with this product by Emerson Electric Co. Substitution of parts or The use of any other control not specifically accessories not designated for use with this product approved for this fan could result in fire, shock and by Emerson El
ページ14に含まれる内容の要旨
Repair Parts 4 2 1 7 3 19 13 8 9 12 14 20 6 10 5 11 18 15 16 17 ETL Model No.: CF550 14
ページ15に含まれる内容の要旨
Repair Parts Listing Key Model Number No. Description CF550BS00 CF550ORB00 * Hanger Ball Assembly, 761655-17 761655-32 Consisting of: 1 Hanger Bracket —— 2 Hanger Ball —— 3 Downrod (4.5”) —— * Parts Bag Containing: 764255 764255-1 4 Wire Connector (5) —— 5 Pin, Clevis (1) —— 6 Clip, Hairpin (1) —— 7 Threaded Stud, #8-32 x 1-1/4” (2) —— 8 Lockwasher, External Tooth #8 (2) —— 9 Knurled Knob, #8-32 (2) —— 10 Screw, Flat Head Blade, #10-24 x .375” (21) —— 11 Washer, Flat, #10 x .50” (21) —— 12 Balan
ページ16に含まれる内容の要旨
Emerson Air Comfort Ceiling Fan Limited Warranty What The Limited Warranty Covers: This limited warranty is offered by Air Comfort Products division of Emerson Electric Co. ("Emerson" "we" or "us") located at the address stated below to the original retail purchaser ("you" or "your") of an Emerson Air Comfort Ceiling Fan product ("Emerson Ceiling Fan") and covers the motor and the other components and accessories of the Emerson Ceiling Fan against all defects in workmanship and materials. What T