ページ1に含まれる内容の要旨
CENTRIFUGAL FANS & BLOWERS
better AIRFLOW
TM
by DESIGN
FCU
UTILITY
FANS
• Forward curved impeller
Heavy guage, steel construction
Discharge rotatable to 8 positions
CW & CCW rotation
AMCA Type A, B & C construction available
Arrangement 10, SWSI, Class I
Sizes range from 8” to 24”
Capacities from 237 to 20,056 cfm
ページ2に含まれる内容の要旨
FCU UTILITY FANS STANDARD FEATURES & BENEFITS • Heavy gauge, rugged welded steel construction Forward curved impeller Self-aligning pillow block bearings Standard bearings have 100,000 hours average life CW & CCW rotation Discharge rotatable to 8 positions Rigid circular stamped inlet ring Adjustable V-belt drive TEFC industrial duty motor AMCA Class I construction ACCESSORIES / OPTIONS Belt guard Flanged inlets & outlets Drain fitting Protective coatings Heat sling
ページ3に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -0 08 8 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP 1.25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 237 800 758 0.02 909 0.03 266 900 775 0.03 917 0.04 1049 0.05 296 1000 798 0.03 931 0.04 1055 0.06 1172 0.07 326 1100 825 0.04 949 0.05 1067 0.06 1178 0.08 1285 0.09 355 1200 854 0.04 971 0.06 1083 0.07 1189 0.08 1290 0.10 1388 0.12 1482 0.13 385 1300 886 0.05 997 0.06 1102 0.08 1203 0.09 13
ページ4に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -0 09 9 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP 1.25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 374 800 615 0.03 730 0.04 421 900 635 0.04 741 0.05 841 0.06 468 1000 658 0.05 757 0.06 850 0.07 940 0.09 515 1100 685 0.06 777 0.07 865 0.09 949 0.10 1030 0.12 562 1200 714 0.07 801 0.09 883 0.10 962 0.11 1039 0.13 1113 0.15 1185 0.16 608 1300 745 0.09 826 0.10 904 0.12 979 0.13 1051 0.15 1
ページ5に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -1 11 1 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP 1.25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 509 800 522 0.04 621 0.06 572 900 538 0.05 630 0.07 716 0.08 636 1000 558 0.06 642 0.08 723 0.10 801 0.12 700 1100 580 0.07 659 0.09 734 0.11 807 0.13 877 0.15 763 1200 603 0.09 678 0.11 749 0.13 817 0.15 884 0.17 948 0.20 827 1300 629 0.11 699 0.13 766 0.15 830 0.17 894 0.19 955 0.22 1014 0
ページ6に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -1 12 2 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP 1.25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 686 800 431 0.06 513 0.08 772 900 446 0.07 519 0.09 858 1000 464 0.08 531 0.11 596 0.13 944 1100 485 0.10 546 0.13 606 0.15 665 0.18 1030 1200 508 0.12 564 0.15 619 0.17 674 0.20 728 0.23 1115 1300 531 0.15 584 0.17 635 0.20 686 0.23 737 0.26 787 0.29 1201 1400 555 0.18 606 0.20 654 0.23 701
ページ7に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -1 13 3 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP 1.25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 839 800 392 0.07 944 900 403 0.08 474 0.11 1049 1000 418 0.12 482 0.13 546 0.16 1154 1100 435 0.12 493 0.15 551 0.19 610 0.22 1259 1200 454 0.15 508 0.18 561 0.21 614 0.25 668 0.29 1364 1300 474 0.17 524 0.21 573 0.24 623 0.28 672 0.32 721 0.37 1469 1400 495 0.21 542 0.24 588 0.28 634 0.32 6
ページ8に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -1 15 5 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP 1.25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 1024 800 346 0.07 409 0.10 1152 900 359 0.09 415 0.12 471 0.15 1280 1000 375 0.11 426 0.14 476 0.17 527 0.21 1408 1100 393 0.14 439 0.17 485 0.20 531 0.24 577 0.28 1536 1200 412 0.17 455 0.20 497 0.23 539 0.27 582 0.31 624 0.35 1664 1300 432 0.20 473 0.23 512 0.27 551 0.31 590 0.35 628 0.39
ページ9に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -1 16 6 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP 1.25 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 1248 800 328 0.10 388 0.13 1404 900 340 0.12 394 0.15 448 0.19 1560 1000 355 0.15 403 0.18 452 0.22 500 0.27 1716 1100 371 0.18 416 0.22 460 0.26 504 0.30 548 0.35 1872 1200 389 0.21 430 0.26 471 0.30 511 0.35 552 0.40 592 0.45 2028 1300 408 0.26 447 0.30 484 0.35 522 0.40 559 0.45 596 0.50
ページ10に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -1 18 8 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 1519 800 296 0.11 352 0.16 1709 900 306 0.14 356 0.19 406 0.24 1899 1000 318 0.17 364 0.22 409 0.27 454 0.33 2089 1100 331 0.20 374 0.25 416 0.31 457 0.37 497 0.44 2279 1200 346 0.24 386 0.29 425 0.35 463 0.42 500 0.49 537 0.56 2469 1300 361 0.29 399 0.34 435 0.40 471 0.47 506 0.54 540 0.61 575 0.69 2659 14
ページ11に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -2 20 0 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 1853 800 256 0.14 308 0.19 2084 900 263 0.16 309 0.22 2316 1000 272 0.20 314 0.26 356 0.33 2548 1100 282 0.24 321 0.30 360 0.37 398 0.45 2780 1200 294 0.29 330 0.35 366 0.42 401 0.50 436 0.59 3011 1300 307 0.34 341 0.41 374 0.48 406 0.56 439 0.65 471 0.74 3242 1400 320 0.40 352 0.47 383 0.55 413 0.63 444 0.
ページ12に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -2 22 2 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 2262 800 232 0.16 2544 900 236 0.19 2827 1000 242 0.23 285 0.31 3110 1100 250 0.27 289 0.35 328 0.45 3392 1200 259 0.32 294 0.40 330 0.50 367 0.60 3675 1300 269 0.38 302 0.47 335 0.56 368 0.67 401 0.78 3958 1400 280 0.45 310 0.54 341 0.63 372 0.74 403 0.86 434 0.99 4241 1500 291 0.52 320 0.62 348 0.72 377 0
ページ13に含まれる内容の要旨
FCU UTILITY FANS M MO OD DE EL L:: F FC CU U- -2 24 4 CFM Outlet Vel. 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1.00 SP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP FPM 2766 800 209 0.19 252 0.28 3112 900 214 0.23 254 0.32 3458 1000 220 0.28 257 0.37 292 0.47 3804 1100 228 0.33 262 0.43 295 0.53 326 0.64 4150 1200 236 0.39 268 0.49 299 0.60 329 0.72 357 0.84 4495 1300 245 0.47 275 0.57 304 0.68 332 0.80 360 0.93 386 1.06 4841 1400 254 0.55 283 0.66 311 0.77 337 0.89 363 1.
ページ14に含まれる内容の要旨
FCU UTILITY FANS DESIGNATIONS FOR ROTATION & DISCHARGE CW ROTATION TH BH DB UB CLOCKWISE CLOCKWISE CLOCKWISE CLOCKWISE TAU BAU TAD BAD CLOCKWISE CLOCKWISE CLOCKWISE CLOCKWISE CCW ROTATION TH DB BH UB COUNTER-CLOCKWISE COUNTER-CLOCKWISE COUNTER-CLOCKWISE COUNTER-CLOCKWISE BAD BAU TAU TAD COUNTER-CLOCKWISE COUNTER-CLOCKWISE COUNTER-CLOCKWISE COUNTER-CLOCKWISE Note: 1. Direction of rotation is determined from drive side of fan. 2. On single inlet fans, drive side is always considered as the side op
ページ15に含まれる内容の要旨
FCU UTILITY FANS PRODUCT SPECIFICATION GUIDE 1.0 GENERAL A. Fans shall be model FCU, as manufactured by Continental Fan Manufacturing Inc., of Buffalo, NY, and of the size, capacity and rotation as indicated on the drawings and fan schedule. B. Fans shall be single width, single inlet, arrangement 10, class I. C. Fans shall be rated and tested in accordance with ANSI/AMCA Standard 210-99. D. All motors and electrical components shall conform to NEMA standards. 2.0 FAN HOUSING A. Fan housing and
ページ16に含まれる内容の要旨
FCU UTILITY FANS FCU-W-1004