ページ1に含まれる内容の要旨
Model HMR-103,104,105,106,107
SECTION 2. INSTALLATION
2-1. INTRODUCTION
This section provides the installation instructions for the Henny
Penny Heated Merchandiser.
Installation of this unit should be performed only by a qualified
service technician.
Do not puncture the heated merchandiser with any objects
such as drills or screws as component damage or electrical
shock could result.
The Henny Penny Heated Merchandiser is tested, inspected and
2-2. UNPACKING
expertly packed to ensure arrival a
ページ2に含まれる内容の要旨
Model HMR-103,104,105,106,107 2-3. ELECTRICAL The heated merchandiser is available from the factory, wired for CONNECTION 120/208-240 volts, single or three phase, (includes neutral), 220-240 volts, or 380-415 volts. Refer to the table at left, and bottom, for proper NEMA NUMBERS: power connection. Model 208/240-1 ph 208-3 ph 240-3 ph 107 14-50P L21-30P Hardwire 106 14-50P L21-30P Hardwire International units are not supplied with cord and plug, and must be provided upon installation. If tw
ページ3に含まれる内容の要旨
Model HMR-103,104,105,106,107 2-4. ELECTRICAL DATA TABLE COMBI- AMPS COMBI- AMPS MODEL NATION VOLTS KW 1 PHASE 3 PHASE MODEL NATION VOLTS KW 1 PHASE 3 PHASE HMR-107 7S 120/208 5.0 24 18 HMR-107 3F/2S/2F* 120/208 6.0 29 19 6.7 32 22 7.8 37 23 120/240 5.0 16 16 120/240 6.0 25 17 7.0 29 20 8.1 34 21 220-240 5.4 22 N/A 220-240 6.4 27 N/A 7.5 31 N/A 8.5 36 N/A 380-415 5.4 N/A 11 380-415 6.4 N/A 11 7.5 N/A 11 8.5 N/A 13 HMR-107 7F 120/208 6.0 29 19 HMR-107 2S
ページ4に含まれる内容の要旨
Model HMR-103,104,105,106,107 2-4. ELECTRICAL DATA TABLE (Continued) COMBI- AMPS COMBI- AMPS MODEL NATION VOLTS KW 1 PHASE 3 PHASE MODEL NATION VOLTS KW 1 PHASE 3 PHASE HMR-106 3S/2F* 120/208 5.2 25 17 HMR-105 3F/2S* 120/208 4.2 20 14 (Cont.) 6.7 32 20 (Cont.) 5.5 26 17 120/240 5.2 22 15 120/240 4.2 18 12 7.0 29 18 5.7 24 15 220-240 5.5 23 N/A 220-240 4.5 19 N/A 7.3 31 N/A 6.0 25 N/A 380-415 5.5 N/A 11 380-415 4.5 N/A 8 7.3 N/A 11 6.0 N/A 9 HMR-106 2S/
ページ5に含まれる内容の要旨
Model HMR-103,104,105,106,107 2-5. CABINET DIMENSIONS 803 2-5
ページ6に含まれる内容の要旨
Model HMR-103,104,105,106,107 2-6. CENTER GLASS These are the instructions for installing the center glass on units INSTALLATION that are combination, self-serve and standard merchandisers. 1. Notice the location of the bracket on unit, as indicated. 2. Using a 3/8” socket, or nut driver, loosen the 2 acorn nuts securing the bracket, but do not remove. 3. Slide bracket off from around the 2 acorn nuts. 2-6 1202
ページ7に含まれる内容の要旨
Model HMR-103,104,105,106,107 2-6. CENTER GLASS INSTALLATION (Continued) 4. Place glass in divider track as shown. 5. Slide bracket onto glass and align to its original position around the 2 acorn nuts. 6. Retighten the 2 acorn nuts. 1202 2-7
ページ8に含まれる内容の要旨
Model HMR-103,104,105,106,107 2-7. SIDE GLASS Install the side panel glass, on both sides of the unit, as follows: INSTALLATION 1. Pull out plunger on retainer and turn clockwise to lock open. 2. Slide the glass into the channel on the side rail, making sure the glass seats into the groove on the upright. Step 1 3. Align the hole in the glass with the plunger of the retainer. 4. Turn the plunger of the retainer clockwise again, to lock