ページ1に含まれる内容の要旨
PROPANE CONSTRUCTION
FORCED AIR HEATER
OWNER’S MANUAL
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Models
BLP30
REM30LP
30,000 Btu/Hr
IMPORTANT: Read and understand this manual before assembling, starting or servicing
heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS BODI
ページ2に含まれる内容の要旨
SAFETY INFORMATION 2 SAFETY INFORMATION WARNINGS • Install and use heater with care. Follow all local ordinances and WARNING: This product contains and/or generates codes. In the absence of local ordinances and codes, refer to the chemicals known to the State of California to cause Standard for Storage and Handling of Liquefied Petroleum Gas, cancer or birth defects, or other reproductive harm. ANSI/NFPA 58 and the Propane Gas Installation Code, CAN/ CGA B149.2. This instructs on the safe stor
ページ3に含まれる内容の要旨
SAFETY INFORMATION 3 3 PRODUCT IDENTIFICATION UNPACKING FUNDAMENTALS OF OPERATION SAFETY INFORMATION UNPACKING Continued 1. Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regu- • Keep heater away from strong drafts, water spray, rain, or drip- lator assembly) for storage. ping water. 2. Remove all items from carton. • Do not leave heater unattended. 3. Check all items for shipping damage. If heater is damaged, • Keep childre
ページ4に含まれる内容の要旨
ASSEMBLY 4 PROPANE SUPPLY INSTALLATION ASSEMBLY PROPANE SUPPLY 1. Remove screw from top of fan guard. Discard screw. Propane gas and propane tank(s) are to be furnished by the user. 2. Insert nut clip (provided with handle) with flat side facing up Use this heater only with a propane vapor withdrawal supply system. through slot in top of shell. Align holes in nut clip with screw See Chapter 5 of the Standard for Storage and Handling of Liquefied hole behind slot in top of shell. (see Figure 4). P
ページ5に含まれる内容の要旨
INSTALLATION 5 5 VENTILATION OPERATION INSTALLATION OPERATION Continued WARNING: Review and understand the warnings 3. Connect hose to valve inlet (see Figure 7). Tighten firmly us- in the Safety Information section, page 2. They are ing a wrench. needed to safely operate this heater. Follow all local IMPORTANT: Use extra hose or piping if needed. Install ex- codes when using this heater. tra hose or piping between hose/regulator assembly and pro- TO START HEATER pane tank. You must use the regu
ページ6に含まれる内容の要旨
OPERATION STORAGE 6 MAINTENANCE SPECIFICATIONS OPERATION Continued 1. Keep heater clean. Clean heater annually or as needed to re- NOTICE: If heater is unplugged or power outage move dust and debris. If heater is dirty or dusty, clean heater occurs while heater is running, the thermal limit with a damp cloth. Use household cleaners on difficult spots. device will stop fuel flow. A few seconds occur before 2. Inspect heater before each use. Check connections for leaks. the thermal limit device ac
ページ7に含まれる内容の要旨
TROUBLESHOOTING 7 7 TROUBLESHOOTING Note: For additional help, visit DESA Heating WARNING: Never service heater while it is plugged in, con- Products’ Technical Service web site at nected to propane supply, operating, or hot. Severe burns and www.desatech.com. electrical shock can occur. OBSERVED FAULT POSSIBLE CAUSE REMEDY Fan does not turn when heater is plugged in. 1. No electrical power to heater 1. Check voltage to electrical outlet. If volt- age is good, check heater power cord for breaks
ページ8に含まれる内容の要旨
SERVICE PROCEDURES 8 SERVICE PROCEDURES WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur. ELECTRICAL SYSTEM Setscrew The entire electrical system for this heater is contained within the motor. If any part of the electrical system is damaged, you must replace motor. MOTOR Figure 10 - Setscrew Location 1. Remove three screws that attach fan guard to heater shell. 2. Remove motor and fan guard from hea
ページ9に含まれる内容の要旨
SERVICE PROCEDURES 9 9 SERVICE PROCEDURES Continued 5a. If replacing fan, remove old fan and discard. Go to step 7 below. 6. Run ignitor wire from new ignitor through notch in filler panel. Attach ignitor wire to piezo ignitor. 5b. If cleaning fan, use soft cloth moistened with kerosene or solvent. 7. Set gap between ignitor electrode and target plate to .17" (see 6. Dry fan thoroughly. Figure 15). 7. Place fan onto motor shaft. Make sure set screw contacts flat sur- face on motor shaft. Tighten
ページ10に含まれる内容の要旨
ILLUSTRATED PARTS BREAKDOWN Models BLP30 and REM30LP 10 ILLUSTRATED PARTS BREAKDOWN MODELS 1 BLP30 AND REM30LP 6 16 15 13 5 7 2 8 23 14 18 19 4 20 12 9 10 22 21 11 3 17 For more information, visit www.desatech.com For more information, visit www.desatech.com 104163-01H
ページ11に含まれる内容の要旨
PARTS LIST 11 Models BLP30 and REM30LP 11 PARTS LIST MODELS BLP30 AND REM30LP This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 ** Combustion Chamber 1 2 ** Unichassis (BLP30) 1 ** Unichassis (REM30LP) 1 3 M11143-1 Bushing, Strain Relief 1 4 M11084-27 Screw 5 5 099237-01 Thermocouple Nut 2 6 103894-01 Target Bracket Kit 1 7 104784-0
ページ12に含まれる内容の要旨
ACCESSORIES 12 TECHNICAL SERVICE REPLACEMENT PARTS ACCESSORIES REPLACEMENT PARTS Purchase accessories and parts from your nearest dealer or service WARNING: Use only original replacement parts. center. If they can not supply an accessory or part, either contact your This heater must use design-specific parts. Do not nearest Parts Central (listed in the separate Authorized Service Center substitute or use generic parts. Improper replace- booklet) or contact DESA Heating Products for referral inf
ページ13に含まれる内容の要旨
13 13 OWNER'S REGISTRATION FORM Complete registration form and mail or complete on-line registration at www.desatech.com within 30 days after purchase. Brand: (Reddy Heater, Master, Remington, etc.) Model: (R60, HD15, etc.) Date Purchased: Note: Keep receipt for warranty verification. Serial Number: 7 or 9 digit number located on product or identification tag. First Name: Last N
ページ14に含まれる内容の要旨
Postage Required 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 TAPE TAPE
ページ15に含まれる内容の要旨
OTHER OUTDOOR HEATING PRODUCTS PROPANE/LP FORCED AIR HEATERS PROPANE/LP CONVECTION HEATERS PORTABLE KEROSENE/DIESEL FORCED AIR HEATERS PROPANE/LP TANK TOP HEATERS PROPANE/LP AND NATURAL GAS GARAGE HEATERS PROPANE/LP PROPANE/LP AND NATURAL PATIO HEATERS GAS CHIMENEAS klsuiejlb oeklhi kokle ,,;log;e ;;pdl;lklsuiejlb oe ;e ;;pdl;lklsuiejlb oeklhi kokle ,,;log;e ;;pdl;l WARNING klsuiejlb oeklhi kokle ,,;log;e ;;pdl;l klsuiejlb oeklhi kokle ,,;log;e ;;pdl ;l klsuiejlb oeklhi kokle ,,;log;e ;;p
ページ16に含まれる内容の要旨
16 WARRANTY AND REPAIR SERVICE KEEP THIS WARRANTY Model Serial No. Date of Purchase LIMITED WARRANTY DESA Heating Products warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided. This warranty covers only the cost of parts and labor required to r