ページ1に含まれる内容の要旨
INFRARED VENT-FREE PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
CGP10RLA
WARNING: Improper installa-
WARNING: If the information in this manual is not
tion, adjustment, alteration, ser-
followed exactly, a fire or explosion may result caus-
vice, or maintenance can cause
ing property damage, personal injury, or loss of life.
injury or property damage. Re-
fer to this manual for correct
— Do not store or use gasoline or other
installation and operational pro-
flammable vapors a
ページ2に含まれる内容の要旨
PROPANE/LP GAS HEATER 4. Heater shall not be installed in a bath- SAFETY Due to high temperatures, the room. appliance should be located out INFORMATION 5. Always run heater with control knob of traffic and away from furniture at LOW or HIGH locked positions. and draperies. Never set control knob between locked WARNINGS positions. Poor combustion and higher Do not place clothing or other levels of carbon monoxide may result. IMPORTANT: Read this owner’s flammable material on or near manual care
ページ3に含まれる内容の要旨
OWNER’S MANUAL PRODUCT PRODUCT IDENTIFICATION FEATURES SAFETY PILOT Piezo Ignitor Button This heater has a pilot with an Oxygen Control Knob Depletion Sensing (ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries, or other Grill Guard sources to light heater. Burners Heater Cabinet Front Pan
ページ4に含まれる内容の要旨
PROPANE/LP GAS HEATER Confined and Unconfined Space PROVIDING ADEQUATE AIR FOR VENTILATION The National Fuel Gas Code ANS Z223.1 COMBUSTION AND defines a confined space as a space whose The following are excerpts from National VENTILATION volume is less than 50 cubic feet per 1,000 Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- Btu per hour (4.8 m3 per kw) of the aggre- tion 5.3, Air for Combustion and Ventilation. gate input rating of all appliances installed All spaces in homes fall into one of the t
ページ5に含まれる内容の要旨
OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = _________________cu. f
ページ6に含まれる内容の要旨
PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND 12" VENTILATION Continued VENTILATION AIR Ventilation Grills Into Adjoining Room, Ventilation Option 2 Ventilation Air From Inside Grills Or into Adjoining Building Remove Room, Door into Option 1 This fresh air would come from an adjoining Adjoining Room, unconfined space. When ventilating to an Option 3 adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wa
ページ7に含まれる内容の要旨
OWNER’S MANUAL IMPORTANT: Vent-free heaters add mois- LOCATING HEATER INSTALLATION ture to the air. Although this is beneficial, This heater is designed to be mounted on a wall. installing heater in rooms without enough NOTICE: This heater is intended ventilation air may cause mildew to form for use as supplemental heat. Use from too much moisture. See Air for Com- WARNING: Maintain the mini- this heater along with your pri- bustion and Ventilation, pages 4 through 6. mum clearances shown in Fi
ページ8に含まれる内容の要旨
PROPANE/LP GAS HEATER Thin or Installing Bottom Mounting INSTALLATION Thick Wall Screw Continued (thick wall 1. Locate bottom mounting hole. This shown) Installing Two Mounting Screws hole is near bottom on back panel of 1/16" Space heater (see Figure 11). Note: Wall anchors and mounting screws 2. Mark screw location on wall. are in hardware package. The hardware pack- Solid age is provided with heater. 3. Remove heater from wall. Wall 4. If installing bottom mounting screw Attaching to Wall Stu
ページ9に含まれる内容の要旨
OWNER’S MANUAL INSTALLATION CAUTION: Use pipe joint seal- CAUTION: Use only new, Continued ant that is resistant to liquid pe- black iron or steel pipe. Inter- troleum (LP) gas. nally-tinned copper tubing may CONNECTING TO GAS be used in certain areas. Check SUPPLY your local codes. Use pipe 3/8" Install sediment trap in supply line as shown diameter or greater to allow in Figure 13. Locate sediment trap where it proper gas volume to heater. If is within reach for cleaning. Locate sedi- WARNI
ページ10に含まれる内容の要旨
PROPANE/LP GAS HEATER 2. Pressurize supply piping system by ei- INSTALLATION OPERATING ther using compressed air or opening Continued propane/LP supply tank valve. HEATER 3. Check all joints from propane/LP sup- CHECKING GAS ply tank to equipment shutoff valve (see FOR YOUR SAFETY CONNECTIONS Figure 15). Apply mixture of liquid READ BEFORE soap and water to gas joints. Bubbles LIGHTING WARNING: Test all gas pip- forming show a leak. ing and connections for leaks 4. Correct all leaks at once. W
ページ11に含まれる内容の要旨
OWNER’S MANUAL Control Note: If pilot does not light, refer to OPERATING Knobs Burners Troubleshooting, pages 13 through 15. HEATER Also contact a qualified service person OFF or gas supplier for repairs. Until re- Continued pairs are made, light pilot with match, PILOT see Manual Lighting Procedure. LIGHTING 7. Keep control knob pressed in for 10 INSTRUCTIONS LOW seconds after lighting pilot. After 10 1. STOP! Read the safety information seconds, release control knob. page 10, column 3. Note: I
ページ12に含まれる内容の要旨
PROPANE/LP GAS HEATER We also recommend that you keep the burner INSPECTING tube and pilot assembly clean and free of BURNER dust and dirt. To clean these parts we recom- mend using compressed air no greater than Check pilot flame pattern and burner flame 30 PSI. Your local computer store, hard- pattern often. ware store, or home center may carry com- pressed air in a can. You can use a vacuum PILOT FLAME PATTERN cleaner in the blow position. If using com- Figure 19 shows a correct pilot flame p
ページ13に含まれる内容の要旨
OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater CAUTION: Never use a wire, Note: For additional help, visit DESA and let cool before servicing. Only needle, or similar object to clean International’s technical service web site a qualified service person should ODS/pilot. This can damage ODS/ at www.desatech.com. service and repair heater. pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed an
ページ14に含まれる内容の要旨
PROPANE/LP GAS HEATER TROUBLESHOOTING Continued OBSERVEDPROBLEM POSSIBLE CAUSE REMEDY Burner(s) does not light after ODS/pilot is lit 1. Burner orifice(s) is clogged 1. Clean burner orifice(s) (see Cleaning and Maintenance, page 12) or replace burner orifice(s) 2. Burner orifice(s) diameter is too small 2. Replace burner orifice(s) 3. Inlet gas pressure is too low 3. Contact local propane/LP gas company Delayed ignition of burner(s) 1. Manifold pressure is too low 1. Contact local propane/LP gas
ページ15に含まれる内容の要旨
OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette
ページ16に含まれる内容の要旨
PROPANE/LP GAS HEATER SPECIFICATIONS REPLACEMENT Btu (Variable) 5,500/10,000 PARTS Type Gas Propane/LP Only Note: Use only original replacement parts. Ignition Piezo This will protect your warranty coverage for Pressure Regulator Setting 8" W.C. parts replaced under warranty. Inlet Gas Pressure (inches of water) Maximum 14" PARTS UNDER WARRANTY Minimum 11" Contact authorized dealer from whom you Dimensions, Inches (H x W x D) 1 1 purchased this product. If they cannot sup- Heater 20 /2 x 13 /2 x
ページ17に含まれる内容の要旨
OWNER’S MANUAL PARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. Baltimore Electric Washer Equipment Co. Dayton Hardware 1348 Dixwell Avenue 1715 Main Street P.O. Box 275 Hamden, CT 06514-0322 Kansas City, MO 64108-2195 North Dayton Station 1-800-397-7553 KS, MO, AR Dayton, OH 45404-0275 203-248-7553 816-842-3911 All States Parts Department www.washerparts.com 937-258-3721
ページ18に含まれる内容の要旨
B A PROPANE/LP GAS HEATER 22 ILLUSTRATED 15 PARTS 19 BREAKDOWN 18 21 CGP10RLA 23 8 4 7 17 6 16 20 23 14 5 6 11 3 10 9 13 2 9 12 7-1 1 7-2 ODS/PILOT 104275 18
ページ19に含まれる内容の要旨
OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed PARTS LIST under Replacement Parts on page 16 of this manual. CGP10RLA KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-07 Front Panel Assembly 1 3 099318-03 Grill Guard 1 4 101108-01 Removable Speed Clip 2 5 099469-02 Reflector Assembly 1 6 M15823-37 Screw Hex #8 x 1/4" 10 7 099059-03 ODS/Pilot Assembly 1 7-1 098514-01 Thermocouple 1 7-2 0
ページ20に含まれる内容の要旨
WARRANTY INFORMATION KEEP THIS WARRANTY Model ____________________________________ Serial No. _________________________________ Date Purchased ____________________________ Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEAT