ページ1に含まれる内容の要旨
Chromalox
SERVICE REFERENCE
Installation, Operation
DIVISION 4 SECTION RAD
and
SALES
(Supersedes PG404-9) PG404-10
REFERENCE
RENEWAL PARTS IDENTIFICATION
161-048215-001
DATE APRIL, 2005
Type RAD (Style 3B) Electric Radiant Heaters
!
The Safety Alert Symbol is used to indicate a Before Installing
risk of personal injury
1. Open carton and remove heater at the place of installation.
Familiarize yourself with these instructions before attempting Mounting
ページ2に含まれる内容の要旨
INSTALLATION 5. Reflector Spacer Sheets — Where heaters are not mounted side by side (see Figure 4), reflector spacer sheets can be used between heaters. These reflector spacer sheets and companion reflectors ELECTRIC SHOCK HAZARD. Disconnect all power consisting of an extruded aluminum housing with reflector sheets before installing or servicing heater. Failure to do and mounting clamps are available. Check factory. so could result in personal injury or property dam- age. Heater must be insta
ページ3に含まれる内容の要旨
WIRING 9. SINGLE END WIRING may be made through one of the wiring entries by bringing a lead through it from the opposite end of the heating element using the wire-way provided behind ELECTRIC SHOCK HAZARD. Disconnect all power integral reflector in the housing extrusion. Wire used in mak- before installing or servicing heater. Failure to do so ing such connections must be able to operate in high ambient could result in personal injury or property damage. and have a sufficiently high voltage rat
ページ4に含まれる内容の要旨
OPERATION B. Maximum Ambient Temperatures – Chromalox Radiant Heaters are not recommended for applica- FIRE/EXPLOSION HAZARD. This heater is not tions in ambient temperature exceeding 450˚F. Higher ambient intended for use in hazardous atmospheres where temperatures mean shorter heater life. flammable vapors, gases, liquids or other com- Maximum work temperature in a given time depends on sever- bustible atmospheres are present as defined in the al factors: Reflectivity of work, specific heat of
ページ5に含まれる内容の要旨
RENEWAL PARTS IDENTIFICATION 1 2 Element Reflector 6 Insulation 7 Element Volts kW Model Model Sheet Bushing Support Clip RAD-2063BX35 120 400 RTU-2063AX35 234-013411-031 ————— ————— RAD-2063B 120 600 RTU-2063A-120V 234-013411-011 ————— ————— RAD-2063B 240 600 RTU-2063A-240V 234-013411-011 ————— ————— RAD-2063BX29 120 650 RTU-2063AX29 234-013411-023 ————— ————— 120 RTU-2073A-120V RAD-2073B 700 234-013411-011 ————— ————— 240 RTU-2073A-240V 120 RTU-2083A-120V 208 RTU-2083AV-208V RAD-2083B 800 234-
ページ6に含まれる内容の要旨
RENEWAL PARTS IDENTIFICATION 13 12 11 3 8 4 15 1 12 9 14 10 2 5 6 Aluminum Housing 7 MISCELLANEOUS HARDWARE MISCELLANEOUS PARTS Screws — 9 Terminal Blocks 303-016367-001 (2) #8 x 1” Lg. 248-075519-095 (6) 12 10 Speed Nuts — 272-048153-005 (4) #8 x 3/8” Lg. 248-075519-080 (4) 13 11 Terminal Block — 303-014326-001 (2) #8-32 x 3/8” Lg. 248-075512-053 (4) 14 TERMINAL BLOCK SET HEATER MOUNTING CLAMP ASSEMBLY 168-016585-001 consists of the following: See Figures 1, 2, 3 and 4, page 1. 9 Terminal Block