ページ1に含まれる内容の要旨
NT-series
Programmable Terminal
Operation Manual
Cat. No. V022-E3-1
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
OMRON Product References All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense. The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for anything else. The abbreviati
ページ4に含まれる内容の要旨
ページ5に含まれる内容の要旨
TABLE OF CONTENTS PRECAUTIONS ...................................... xi SECTION 2 Functions of the NT600S ............................. 2 !
ページ6に含まれる内容の要旨
’- ( 4( 5 ’5 # % " SECTION 6 Using Host Link/NT Link/C200H Direct ................ 153 . /0 8 /08$ . & ’" 6# + ) ( " /#; ( 4(; # % 5 "
ページ7に含まれる内容の要旨
About this Manual: This manual describes the installation and operation of the NT600S Programmable Terminals (PTs) and includes the sections described below. Further information is provided in manuals on the Host Interface Units and Support Tool. Refer to the list in Section 1 Introduction. Please read this manual completely and be sure you understand the information provide before attempting to install and operate a Programmable Terminal. Section 1 introduces the PTs, describes the terminology
ページ8に含まれる内容の要旨
Manuals: The related manuals are indicated below. The symbol at the end of the manual number is the revision history symbol. Operating the Programmable terminal and Communicating with the Host NT600S Programmable Terminal Operation Manual V022-E1- (this manual) This operation manual is the manual for the NT600S itself. The NT600S is a unit which integrates a programmable terminal body and host interface unit. However, note that a C200H interface unit is required for com- munications using
ページ9に含まれる内容の要旨
PRECAUTIONS ( ? % % ( %##+ #
ページ10に含まれる内容の要旨
1 Intended Audience This manual is intended for the following personnel, who must also have knowl- edge of electrical systems (an electrical engineer or the equivalent). Personnel in charge of installing FA systems. Personnel in charge of designing FA systems. Personnel in charge of managing FA systems and facilities. 2 General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Before using the product under conditi
ページ11に含まれる内容の要旨
Safety Precautions (continued) WARNING: Do not attempt to take the NT600S apart and do not touch any internal parts while the power is being supplied. Doing either of these may result in electri- cal shock. Switch off the power before replacing the backlight, or you could sustain an electric shock. Caution: Select a proper location referring to Appendix D Installation Environment (page 262). Always switch OFF the power before assembling equipment or connecting cables. Otherwise you could s
ページ12に含まれる内容の要旨
Safety Precautions (continued) The cable’s tensile load is 30 N. Do not subject it to loads greater than this. Otherwise a discontinuity may occur, causing operation to fail. Do not install the NT600S at sites subject to the following conditions, or the product may malfunction: Severe temperature variations Temperatures or humidities outside the ranges stated in the specifications High humidity, condensation Splashing chemical agents Severe oil splashing Corrosive or flammable gases Strong v
ページ13に含まれる内容の要旨
Safety Precautions (continued) Do not disassemble for repairs or modification, or the product may malfunc- tion. The disposal of the NT600S (and used backlights) may be regulated by na- tional or local authorities. Dispose of them in accordance with the laws and regulations of the relevant country and local authority. Never short the + and -- terminals of the battery. Do not recharge, take apart, deform, or discharge it into open flame. Attempting any of these will lead to hazards such as
ページ14に含まれる内容の要旨
ページ15に含まれる内容の要旨
SECTION 2 Functions of the NT600S NT600S is a new programmable terminal (PT) which incorporates a host interface unit and a RS-232C interface unit in a programmable terminal body. It can be easily installed and used. This section gives the operation examples and characteristics of the NT600S so that you will understand the ap- plications of the NT600S. 2-1 Role and Operation of NT600S ............................................... 2 2-1-1 Operations of NT600S ...................................
ページ16に含まれる内容の要旨
Section 1-1 2-1 Role and Operation of NT600S NT600S is a programmable terminal used to display and transmit the information in an FA site. The following gives a general description of the role and operation of the NT600S for those who use a programmable terminal (PT) for the first time. Production Line Status The NT600S displays real-time information about the system and equipment Monitoring operating status, etc. Production Control 1994/1/25 Product NT20M NT600M 560
ページ17に含まれる内容の要旨
Section 1-1 2-1-1 Operations of NT600S Displays Screens The information to be displayed (screen data) can be created on a computer by using support tools and stored in the NT600S. The screen data can be displayed on the NT600S in response to the instructions from a PC/Host or touch switch op- eration. Host PC The screen data designated by instructions from PC/Host or touch switch operation is displayed. The NT600S can be connected to a PC/Host, and receive necessary
ページ18に含まれる内容の要旨
Section 1-2 2-2 Functions of NT600S The NT600S has the following features which are different from those of existing NT600M; 2-2-1 Features Downsized Body The NT600S has thin depth (64 mm or less in the panel) in the NT series. The width is shorter by 50 mm, maintaining the existing display area. The tool connectors are located at the rear of the unit. The communication cable connectors are housed in the unit so that they do not protrude from the unit. The tool conn
ページ19に含まれる内容の要旨
Section 1-2 Availability of the C200H Direct Communication Function The C200H direct communication function can be used if the C200H interface unit (NT-LB122), which must be purchased separately, is mounted to the NT600S. Touch Switch Operation The System Menu can be displayed by using the touch switches located in four corners of the screen. Compatibility with NT600M Existing screen data, user programs, and support tools are compatible.
ページ20に含まれる内容の要旨
Section 1-2 2-2-2 Principal Functions of NT600S Functions Related to the Data Display Character display Characters of various sizes can be displayed. Characters can flash or be highlighted. Figure display Straight lines, circles, and other graphic figures can be displayed. Memory data display Contents of the character-string memory table and the numeral memory table can be dis- played. The memory table contents can be changed from the PC/Host. Bar graph display Bar gr