Digital Thermostat Installation in RV HVAC Systems
Coleman Mach to Hunter Digital Thermostat Instructions
Credit given where credit is due: This page written by Ken Lenger and derived from the text
from Alan Paskey and Les Adams. Credit for the original concept and details of the Coleman
modification is given to Alan Paskey. Les Adams further developed this concept to work with
the Dometic A/C and Atwood furnace. Their comments follow page 2.
The Coleman Mach analog RV thermostat can b
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Digital Thermostat Installation in RV HVAC Systems TEXT OF ALAN PASKEY'S ARTICLE as FOLLOWS (FOR COLEMAN UNITS) The wires coming out of the a/c are as follows: Red = +12 VDC Blue = -12 VDC Green = Fan High Gray = Fan Low White = Furnace Yellow = Compressor The wire terminals on the new stat are as follows: RC = cooling relay RH = heating relay G = Fan W = Heat Y = A/C compressor I hooked up everything as follows: RC = Red wire RH = Red wire G = see notes below W = White wire
ページ4に含まれる内容の要旨
Digital Thermostat Installation in RV HVAC Systems LES ADAMS ARTICLE FOR WIRING HUNTER DIGITAL THERMOSTAT INTO DOMETIC A/C AND ATWOOD FURNACE There was a thread on another BBS by Alan Paskey about his installation of a Hunter Digital Thermostat for his A/C and heat... I have been wanting to do this for some time now and finally got around to going over to "Wally World" (Wal Mart) and buying the thermostat and "getting off my duff" and installing it!!! I installed it yesterday... Unfortuna
ページ5に含まれる内容の要旨
Digital Thermostat Installation in RV HVAC Systems Hunter thermostat Heating System Selector switch set to "HG"... "F/C" selector switch to "F" ... Note that both the Hunter "RC" and "RH" terminals have the ground lead connected to them... I fashioned a jumper wire from one terminal to another... BOTH these terminals are grounded from the same point in my installation... This setup worked very well for me last night... I will continue to test but I believe this wiring documentation is