ページ1に含まれる内容の要旨
Q7100A,C,D
Thermostat Subbases
INSTALLATION INSTRUCTIONS
3. Installer must be a trained, experienced service
APPLICATION
technician.
4. After completing installation, use these instructions
The Q7100 Thermostat Subbases provide electronic
to check out the product operation.
control of commercial 24 Vac single or multistage heat
pump or conventional heating and cooling systems.
Select models have terminals for light emitting diodes CAUTION
LEDs, remote temperature sensors and remote setback
Disco
ページ2に含まれる内容の要旨
Q7100A,C,D THERMOSTAT SUBBASES YES NO NO 5 FEET [1.5 METERS] NO M10074 Fig. 1. Typical location of thermostat or remote-mounted sensor. SUBBASE SUBBASE TT TT T7047C T7047C T7047G T7047G TT TT T T T T T7047C T7047C M4838 TT TT Fig. 2. Two T7047G Sensors providing a temperature averaging network for a T7100/Q7100 Thermostat/Subbase. M4840 Fig. 4. Four T7047C Sensors providing a temperature averaging network for a SUBBASE T7100/Q7100 Thermostat Subbase. TT SUBBASE T7047C TT TT T7047G T7047G T7047G
ページ3に含まれる内容の要旨
Q7100A,C,D THERMOSTAT SUBBASES 3. Remove the subbase from the wall and drill two SUBBASE 3/16 inch holes in the wall (if drywall) as marked. For TT firmer material such as plaster or wood, drill two 7/32 inch holes. Gently tap anchors (provided) into T7047C T7047C T7047C the drilled holes until flush with the wall. 4. Position the subbase over the holes, pulling wires TT TT TT through the wiring opening. 5. Loosely insert the mounting screws into the holes. 6. Tighten mounting screws. T7047C T70
ページ4に含まれる内容の要旨
Q7100A,C,D THERMOSTAT SUBBASES SUBBASE RC OY1 Y2 G X W1W2 B RH T T D D 3 COOL COMPRESSOR HEAT REMOTE DAMPER CONTACTOR 2 RELAY 2 TEMPERATURE SENSOR 1 FAN HEAT HEAT COMPRESSOR RELAY DAMPER CONTACTOR 1 RELAY 1 REMOTE SETBACK TIMER 2 2 L1 L1 (HOT) (HOT) L2 L2 1 CAUTION: EQUIPMENT DAMAGE WILL OCCUR IF POWER IS CONNECTED TO THE D TERMINALS. 2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 3 JUMPER RC TERMINAL TO RH TERMINAL WHEN INSTALLED ON A SYSTEM WITH ONE TRANSFOR
ページ5に含まれる内容の要旨
Q7100A,C,D THERMOSTAT SUBBASES SUBBASE X OE G B W2 W1 Y2 Y1 X2 X4 X1 X3 R T TD D 5 COOL FAN HEAT COMPRESSOR EQUIPMENT REMOTE CHANGEOVER RELAY RELAY 2 CONTACTOR 2 TEMPERATURE VALVE 4 SENSOR MONITOR 2 3 1 2 EM. HT. HEAT HEAT COMPRESSOR EQUIPMENT CHANGEOVER CONTACTOR 1 RELAY RELAY 1 L1 VALVE (HOT) REMOTE MONITOR 1 SETBACK L2 TIMER 1 CAUTION: EQUIPMENT DAMAGE WILL OCCUR IF POWER IS CONNECTED TO THE D TERMINALS. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 EM. HEA
ページ6に含まれる内容の要旨
Q7100A,C,D THERMOSTAT SUBBASES Home and Building Control Home and Building Control Honeywell Inc. Honeywell Limited-Honeywell Limitée Honeywell Plaza 155 Gordon Baker Road P.O. Box 524 North York, Ontario Minneapolis, MN 55408-0524 M2H 2C9 69-0931—3 www.honeywell.com 69-0931—3 Rev. 2-98 L. C. 6