Installation Guide TablE Of CONTENTs Specifications and Accessories ...................................................................................................1 Installation ......................................................................................................................................2 Wiring ..............................................................................................................................................3 Operation .....................
ページ3に含まれる内容の要旨
HZ22 TrueZONE spECifiCa TiONs aNd aCCEssOriEs Input Ratings: RECOMMENDED THERMOSTATS, DAMPERS, AND Voltage: 18-30 VAC 50/60 Hz transformer of 40 VA ACCESSORIES or more. The following are suggested thermostats, dampers, and accessories for use with the TrueZONE panel. Current Draw: Zone Panel: 6.25 VA max. All VA specifications at 24 VAC. Table 1. Recommended Thermostats. System Non-Programmable Programmable Wiring: Heat TH3210D, TH5220D, TH4210D, TH6220D, 18–20-gauge solid (not stranded) wi
ページ4に含まれる内容の要旨
Installation Guide iNsT alla TiON Mount the HZ221 TrueZONE panel near the HVAC equip- ZONE PANEL (WALL MOUNT) 1 BYPASS ment; locate it on a wall, DAMPER stud, roof truss, or cold-air DATS return. RETURN (ALTERNATE LOCATION) DUCT NOTE: The HZ221 TrueZONE panel can be ZONE PANEL mounted in any orientation; (DUCT MOUNT) level it for appearance only. ARD DATS DAMPERS SUPPLY DUCT M28164 Separate the zone panel cover from the base, and use the base as a template to drill mounting holes. 2 Attach
ページ5に含まれる内容の要旨
ZONE 1 DAMPER ZONE 2 DAMPER HZ22 TrueZONE WiriNg Wiring must comply with applicable codes, ordinances, and regulations. CAUTION: Voltage Hazard. Can cause electrical shock or equipment damage. Disconnect power before beginning installation. Wire entire panel before applying transformer power. Install thermostats using instructions provided with thermostats. Connect thermostat to zone panel. To connect wire to the panel, strip 3 approximately 1/4 in. of insulation and push wire into terminal.
ページ6に含まれる内容の要旨
ZONE 1 THERMOSTAT ZONE 2 THERMOSTAT DAMPER DAMPER Installation Guide WiriNg AIR HANDLER 24 VOLT TRANS. C R Connect equipment as shown. 6 AUX/EM HEAT R E C E/Aux FAN RELAY Y G G O Y B The DS/BK terminal is used with a variable-speed fan. DS/BK HEAT PUMP L Connect to the DS, BK, or ODD terminal on the furnace C R equipment. When only one zone calls for heat, cool, or Y fan, the DS/BK terminal operates the fan at low speed REVERSING to reduce airflow. VALVE L1 M28236A (HOT) R R C Connect transf
ページ7に含まれる内容の要旨
ZONE 1 ZONE 2 THERMOSTAT THERMOSTAT DAMPER DAMPER HZ22 TrueZONE OpEra TON i The HZ221 TrueZONE panel contains an LED display that communicates system and zone status. The LEDs indicate the following information. Table 5. LED Operation. LED Description HEAT Solid when in heat. Blinking when DATS temperature exceeds 120°F (49°C) and calling for heat pump only. Blinking when DATS temperature exceeds 160°F HZ221 (71°C) and calling for heat pump and auxiliary heat. At 150°F (66°C), auxiliary h
ページ8に含まれる内容の要旨
WarraNTy Honeywell warrants the products in this catalog (except those parts designated on Honeywell’s price lists as not covered by this warranty) to be free from defects due TM to workmanship or materials, under normal use and service, for the following warranty periods. Honeywell VisionPRO®, Commercial VisionPRO , FocusPRO®, PRO TM TM TM 4000, PRO 3000, LineVolt PRO, Digital Round , and Modern Round (T87K, N) Series Thermostats with a date code of 0501 or later: sixty (60) months from date