EDGE Pro
33CS
Commercial Thermostat
Owner’s Manual
Part Numbers 33CS2PPRH-01 and 33CS2PP2S-01
• programming option (indicates which settings are being
SAFETY CONSIDERATIONS
adjusted)
Read and follow manufacturer instructions carefully. Fol-
• system is in auxiliary (supplemental) mode
low all local electrical codes during installation. All wiring
• cooling set point
must conform to local and national electrical codes. Improper
• heating set point
wiring or installation may damage thermostat.
•
ページ2に含まれる内容の要旨
right corner on the screen, depending on the mode the system is in. If it is the first time the thermostat is being used, the “heat” occupied indicator will be displayed. The preprogrammed heating or cooling temperatures are displayed in a box at the bottom of the screen. Change the displayed temperature set point by pressing the up or down buttons until the desired setting is reached. holiday To change other temperature set points, press the mode but- ton. The arrow will move to the next mode a
ページ3に含まれる内容の要旨
3. The arrow will be pointing to “occ” on the screen. To set Then use the soft keys to change the start time, the heat- the occ period start time, press the soft button under the ing set point, and the cooling set point. hour or minute indictor and then press the up or down 9. Press the soft button under the days of the week until the buttons to change the time. arrow is pointing to the next day that will be pro- 4. Set the heating temperature set point for that time period grammed. by pressing
ページ4に含まれる内容の要旨
around the date. To set the date (D), press the up button condensation on the windows, select a number lower than and stop on the desired date. 5. If there seems to be a lot of static electricity, which of- ten means the air is too dry, select a number higher than 5. 3. If the month (M) needs to be changed, press the soft but- ton under the month on the screen. The selection box will 5. Close the thermostat door. move to the month number. Press the up button to set the To turn off the humidify o
ページ5に含まれる内容の要旨
5. Press the done button. To switch thermostat operation, perform the following: 6. Close the thermostat door. 1. Open the thermostat door. BACKLIGHTING — The thermostat may feature a low level 2. Press and hold the buttons underneath the heat and cool amount of backlighting until a button is pressed, which increas- set points simultaneously. The screen will display “01” es the lighting temporarily. The user can adjust the intensity of and up to three reset reminders. the backlighting or turn it
ページ6に含まれる内容の要旨
means, for example, that if the unocc period temperature set- Table 4 — Thermostat Error Code Descriptions ting is lower than the period that precedes it, then the thermo- ERROR stat will start cooling down the space before the beginning of DESCRIPTION CODE the scheduled unocc period. The thermostat does this at an en- The system is not communicating properly. Call the E1 ergy efficient rate. This not only helps make the space as com- local Carrier representative for service fortable as possibl