ページ1に含まれる内容の要旨
WT-62U Digital Window Thermometer
Features:
• Clear functional design
• Easy to read outdoor temperature from indoors
• Maximum and minimum values with auto reset
• Easy to mount
• Weather resistant
Specifications:
Measuring range: -22 ºF to +122 ºF
Resolution: 0.2 ºF
Temperature Updating Interval: Every 10 Seconds
Battery: 1 AAA
Inserting the Battery:
1. The battery cover is located on the back of the
thermomet
ページ2に含まれる内容の要旨
NOTE: The thermometer will automatically time out and return to the normal display mode after approximately 30 seconds. Installation: 1. Select your location for mounting in an area that is easy to view. NOTE: The design of the thermometer is such that the display will appear darker when looking at an upward angle at the display. It is recommended to mount the thermometer slightly above eye level to ensure the best viewing of the display. 2. Clean the glass surface completely b
ページ3に含まれる内容の要旨
WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can only
ページ4に含まれる内容の要旨
WS-9013U Wireless 433 MHz Radio-controlled Weather Station Instruction Manual
ページ5に含まれる内容の要旨
Topic Page Inventory of Contents/Additional Equipment 3 About WWVB 4 Quick Set-Up Guide 5 Detailed Set-Up Guide Battery Installation 6-7 Program Mode Programming Sequence 7 Function Keys 8 12/24 Hour Time Setting 8 Time Zone Setting 8-9 Daylight Saving Time Setting 9-10 Time Setting (WWVB & Manual) 10-11 Setting Day, Date and Year 11-12 Selecting °F or °C 12 Setting the LCD Contrast 13 Features Indoor Temperat
ページ6に含まれる内容の要旨
INVENTORY OF CONTENTS 1. The weather station (Figure 1). 2. One TX6U remote temperature sensor with mounting bracket (Figure 2). 3. Three each, ½” Philips screws. 4. One strip double-sided adhesive tape. 5. Instruction Manual and Warranty Card. Figure 2 Time LCD Date LCD Mounting Indoor LCD Bracket Outdoor LCD Figure 1 ADDITIONAL EQUIPMENT (not included) 1. Two, fresh AA 1.5V batteries for indoor weather station. 2. Two, fresh AA 1.5V ba
ページ7に含まれる内容の要旨
ABOUT WWVB (Radio Controlled Time) The NIST (National Institute of Standards and Technology—Time and Frequency Division) WWVB radio station is located in Ft. Collins, Colorado and transmits the exact time signal continuously throughout the United States at 60 kHz. The signal can be received up to 2, 000 miles away through the internal antenna in the weather station. However, due to the nature of the earth’s ionosphere, reception is very limited during daylight hours. The weather stat
ページ8に含まれる内容の要旨
QUICK SET-UP GUIDE Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the indoor weather station and remote temperature sensor 3 to 5 apart. 2. Batteries should be out of both units. 3. Place the batteries into the remote temperature sensor first then into the indoor weather station. (All remote temperature sensors must be started before the indoor weather station) 4. DO NOT PRESS ANY BUTTONS FOR 15 MINUTES. In this time the indoor weather station
ページ9に含まれる内容の要旨
DETAILED SET-UP GUIDE I. BATTERY INSTALLATION A. REMOTE TEMPERATURE SENSOR 1. Remove the mounting bracket. The bracket snaps on and off easily. 2. Remove the battery cover, by sliding the cover down. 3. Observing the correct polarity install 2 AA batteries. The batteries will fit tightly (to avoid start-up problems make sure they do not spring free). 4. Replace the battery cover by sliding upwards. Be sure battery cover is on securely. B. INDOOR WEATHER STATION 1
ページ10に含まれる内容の要旨
PROGRAM MODE If 30 seconds are allowed to pass or either the IN or Programming Note: the OUT button is pressed during programming modes, the unit will set the last information entered—the display will stop flashing and return to normal time-date readings. If you don’t leave the program mode during the programming of sections III through VIII, you can advance to step 3 of the next program setting. If you do leave the program setting (or want to program a specific setting) follow each i
ページ11に含まれる内容の要旨
II. FUNCTION KEYS The function keys are operated by pressing the key corresponding to the operation that you want to perform. II. 12 OR 24 HOUR TIME SETTING 1. Press and hold the “SET” button for 3 seconds or until “12 h” flashes in the DATE LCD. 2. Press and release the “CH” button to toggle between 12 and 24-hour time. 3. Press and release the “SET” button to confirm the 12/24-hour setting and to advance to Time Zone Setting. III. TIME ZONE SETTING The default time
ページ12に含まれる内容の要旨
4. Select your appropriate Time Zones time zone using the GMT 0 “CH” button. During selection of the Time Atlantic -4 Zone, the 3 letter EST; Eastern -5 abbreviations for the time CST; Central -6 zones found in North MST; Mountain -7 America will flash across PST; Pacific -8 the top of the TIME LCD. Observe the chart ALA; Alaska -9 below, showing the HAW; Hawaii -10 corresponding abbreviations, time zones, and codes. Note: There are more time zones represented by numbe
ページ13に含まれる内容の要旨
6. Press and release the “SET” button to confirm and advance to the Time setting mode. V. TIME There are two methods by which the time can be set: A) Automatically via WWVB reception or B) Manually. A. WWVB (Remote Control Time) This method requires you to do nothing except wait for the signal to be received and to select a time zone. Reception usually takes approximately 6-10 minutes during optimal conditions. The best conditions for reception is at night, between mid
ページ14に含まれる内容の要旨
5. Press and release the “SET” button to confirm the hour setting and to advance to the minute setting mode. 6. The minute digits should be flashing. Press and release the "CH” button to change the minutes—increasing the minutes by increments of 1 with each press of the “CH” button. 7. Press and release the “SET” button to confirm the minutes and to advance to the Day, Date, and Year setting mode. Note: In 12h mode, “PM” will appear to the left of the time during PM hours. If the ti
ページ15に含まれる内容の要旨
5. The numeric-month will be flashing in the DATE LCD. Press and release the “CH” button to select to the current month. 6. Press and release the “SET” button to confirm the numeric- month, and to enter the numeric-day setting mode. 7. The numeric-day will be flashing, press and release the “CH” button to select the current day. 8. Press and release the “SET” button to confirm and to enter the year setting mode. 9. The default-year will be flashing, press and release the “CH” to sel
ページ16に含まれる内容の要旨
VIII. SETTING THE LCD CONTRAST 1. Press and hold the “SET” button for 3 seconds or until “12h” or “24h” flashes in the DATE LCD. 2. Press and release the “SET” button 10 more times to reach the LCD contrast setting mode. 3. The default setting—“Lcd 5” will flash in the DATE LCD. 4. There are 8 LCD contrast levels to choose from—“Lcd 0” is the lightest and “Lcd 7” is the darkest. 5. Press and release the “CH” button to toggle through the settings. 6. Press and release either the “I
ページ17に含まれる内容の要旨
FEATURES OF THE WS-9013U WWVB Icon (indicates Radio- WWVB Tower Icon (indicates controlled time time reception) function turned on) Low Battery Remote Temperature Satellite icon (indicates Sensor Channel Indicator outdoor transmission) I. INDOOR TEMPERATURE The current indoor is displayed in the INDOOR LCD and is updated every 10 seconds. II. OUTDOOR TEMPERATURE The outdoor temperature is viewed in the OUTDOOR LCD. The outdoor temperatu
ページ18に含まれる内容の要旨
III. MINIMUM AND MAXIMUM TEMPERATURE RECORDS The WS-9013U keeps a record of the MINIMUM and MAXIMUM temperature and the time and date of their occurrence—for both the indoor and outdoor modes. A. VIEWING THE INDOOR TEMPERATURE RECORDS 1. Press the “IN” button once. “MIN” appears in the upper portion of the flashing INDOOR LCD indicating that the minimum temperature and the time and date of occurrence are displayed. The minimum records will display for 20 seconds. 2. Press
ページ19に含まれる内容の要旨
C. RESETTING THE MIMIMUM AND MAXIMUM RECORDS 1. All the indoor records (minimum and maximum) will be reset after the “IN” button is pressed and held for 5 seconds. 2. All the outdoor records (minimum and maximum) will be reset after the “OUT” button is pressed and held for 5 seconds. IV. ADDING OUTDOOR REMOTE CONTROL SENDERS (OPTIONAL) The WS-9013U is able to receive signals from 3 different remote temperature sensors. The remote temperature sensor model(s) that you choose w
ページ20に含まれる内容の要旨
3. Place all remote temperature sensor units in a numeric sequential order. 4. In sequential order, install batteries (follow the same battery installation procedures seen in section I. A) of the Detailed Set-Up Guide). 5. Install batteries into the indoor weather station. 6. Follow the Detailed Set-Up Guide for programming and operating instructions. B. VIEWING AND OPERATING WITH MULTIPLE REMOTE TEMPERATURE SENSOR UNITS 1. To view the temperature of a different remote temperature