ページ2に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 1 . Specifications 2 . Installation 2.1 Front & Back View of Indicator 2.2 Keyboard Function 2.3 Connecting Loadcell to Indicator 3. Calibration 4. Operating Instructions 4.1 Starting and Starting auto zero setting at turning on 4.2 Manual Zero Setting (Semi-automatically setting zero ) 4.3 Tare Function 4.4 Connecting Scoreboard to Indicator 4.5 Connecting Pinter to Indicator 4.6 Connecting Serial Communication port to Indicator 4.7 Setting of Time and
ページ3に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 1 Specification + 1 Model XK3190-A1 2 Sample rated 5~25 times / sec 3 Load cell sensitivity 1~ 2mv/v 4 Division 1/2/5/10/20/50/100 optional 5 Display 7-bits LED digital display 0.56” in character height and 7 status indicating. 6 Clock can display day/month/year and second/minute/hour 7 Scoreboard display interface Using serial output method : current loop signal, transmission distance ≤50m RS323 signal, transmission distance ≤30m 8 Communication
ページ4に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 2. Installation 2.1 Front & Back View of the Indicator UNIT:KG 1 2 3 ACCU PRE-T FUN TARE ENTER 4 5 6 0 MONEY PRICE AUTO DATE TIME TARE STABLE CLEAR CHECK DATE STORE WEIGH 7 8 9 SET CALB TIME PRINT ZERO PRINT (Graph 2-1) Front View of Indicator * ACCU - accumulating FUN- function CALB – Calibrating ( 25 ) pins (15 ) pins
ページ5に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 2.2 Keyboard Function Key Function 1 [ACCU],[ UNIT No meaning PRICE] 2 In calibration mode, pressing [PRE-TARE/2] , can input digital key “2”; In weighing mode, the key is used for presetting tare. 3 [DELETE/4] In calibration mode, pressing [DELETE/4], can input digital key “4”; In weighing mode, it is deleting function key , more details shown in episode “deleting”. 4 [CHECK/5] In calibration mode, pressing [CHECK/5], can input digital key “5”; In w
ページ6に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 15 In calibration or parameters setting mode, pressing [weigh], it will exit from original calibration or setting mode and return to weighing mode. 2.3 Connecting Loadcell to Indicator 1. The 9-pin socket is used for the link-up of loadcell, which has been clearly shown in the graph 2-3. 2. The 4-pin shielded cable is used, +S must be short connected with +E, -S and -E. The indicator does not have the function of long distance compensation. 3. ▲ !Ind
ページ7に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 3. Calibration According to the Graph 2-3, connecting Indicator and loadcell, and the indicator enters weighing mode. 1. Connecting calibration jumper to the 15- pin socket on the indicator back panel. (There is a 15-pin plug in the packing carton with its 14-pin short connected with 15-pin. ) 2. According to table 4-3, carry out calibration step by step. Table 4 - 1 step Operation Display Explanation 1 press [ CALB] after calibration jumper
ページ8に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 step Operation Display Explanation 8 [ A LoAd1] Loading weight ≥ 5% Max.。 press [ 1 ] [ 5 ] [ d 1500 ] Example: 1500 [ 0 ] [0 ] After stable light is on, press [ Enter ] press [ Enter ] key. 9 press [ Enter ] [ noLoAd ] Confirming zero position again. 10 [ ALoAd2 ] Reloading weight on scale ≥50% Max. It is better that this loading weight is press [2] [0] [ 20000 ] near the F.S. Example: 20000 [0][0] [0] After stable light is on
ページ9に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 out. 4. . Operating Instructions 4.1 Power on 1 When using AC power , power on , setting the ship- form switch at the back cover of the indicator on “1” ; If using DC power , setting the ship- form switch at the back cover of indicator on “1”, then pressing the recover switch, the indicator will perform “999999 - 000000 ” selfchecking. And then enter weighing mode. Or after pressing any key, self-checking stops and enters weighing mode automaticall
ページ10に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 (Graph 4-1) Serial Communication port and score display port 4.4 Connecting Scoreboard to Indicator 1. The display interface of scoreboard is 15-pin socket, which has been clearly shown in the Graph 4-1. 2. The scoreboard signal is 20mA continuous current loop, outputting in binary code, the baud rate is 600. 4.5 Connecting Printer to Indicator 1. The print port adopts parallel output and 25-pin connecting socket, which has been clearly shown i
ページ11に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 ▲ The printer must be compatible to the indicator, please choose the recommended printer. ▲ The printer GND can not be connected to the power GND, otherwise the indicator or printer will be destroyed. 3. Set print parameters step operating display Explanation 1 press [PRN Set ] [ P 00 ] Enter printing setup press [ 9 ] [ 7 ] [ P 97 ] Input password 97 press [ Enter ] 2 [ Auto 1] Auto/ manual print 0: manual 1: Auto press [ 0 ] [ Auto 0 ] Example
ページ12に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 Press[Enter] [ dct ] 1: use discount End Note: You can use discount only when the blank filling mode is selected. 4. print and print format Press [PRINT] key, you can print required weighing data according to print setting. Record Format: Weight Bill Date 97-01-31 NO. Time Gross ( kg ) Tare ( kg ) Net ( kg ) Accumulating(kg) 0001 08.56.16 299.98 1 298.98 298.98 0002 09.00.09 29
ページ13に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 REMARK ★ If setting the odE parameter to 1, you can perform the blank filling priting, at this time the other priting formats are invalid (Records format and document format are invalid). Method: pushing [print] key, if dct parameter is set to 1, it will display [BFL **], inputting the discount rate and pushing [Input], it will print out the blank filling report: if dct parameter is set to 0, it will print out the blank filling report directly, ‘discount r
ページ14に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 communication mode parameters. (2) The sequence of parameters setting as following: Connecting the loadcell , the indicator enters into working mode which is shown in the Graph 2-3. Insert the setting jumper into 15-pin socket at the back of indicator. (There is a 15-pin plug in the packing carton with its 14-pin shorte connected with 15-pin. ). Setup communication parameters as following: Step Operation Display Explanation 1 Press[CALB] Plug in calibration ju
ページ15に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 [ Enter] key or [weighing] key to exit. If it is incorrect, using digital keys enters new date , then press [ Enter ] key. (2) Under weighing status of the indicator, press [ Time ] key, and Time sign lamp is lighted. Indicator display original Time data at this time. If it is correct, then press [ Enter ] key or the [ weighing ] key to exit. If it is incorrect, using digital keys enters new time data, then press [ Enter ] key. 4.8 Weight data store, check and c
ページ16に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 3 Clear Press [ clear ] key, can clean accumulating weight value or stored data. Step Operating Display Explanation 1 press [ Clear ] 2 [ sure 0 ] Selecting clear/not clear 0: no 1: yes press [ 1 ] [ sure 1 ] Example: 1 [ sure 1 ] End 4.9 Insufficient voltage indicating When the storage cell voltage is insufficient, the insufficient voltage lamp is on. At this time the indicator will twinkle.You should set the ship-like switch a
ページ17に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 electronic components will be damaged and electric shock is likely to happen. 5.6 You should cut off power supply of indicator and relevant device before you pull-in and out the connecting line of indicator and external device. ▲ !You must cut off power supply of the indicator , before you plug the connecting line of the loadcell in and out. ▲ !You must cut off power supply of the indicator and the printer, before you plug in connecting line of the printer. ▲ !Yo
ページ18に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 6.3 Wrong setting information indicating 1 Err 13 Wrong setting of the division value . 2 Err 14 Decimal point must be less than 5, please reset the decimal bit. 3 Err 15 Overload warning must be > 100, please reset it. Err 17 Enter new data which should be less than 65000. 6.4 Wrong connection information indicating 1 Err P It means the printer has trouble or is wrongly connected. push any key to quit. 2 Err 01 It means th
ページ19に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 3 Err 21 Calibrating data have been lost in RAM and EPROM, Operator must put in the calibration plug, then reenter the original calibration data, turn on the indicator again or re-calibrate it. 4 Err 22 EPROM has been damaged. 5 Err 23 RAM has been damaged. 6.6 Other information indicating 1. Err 24 In normal operation, you must pull off the calibration jumper.The indicator is under normal opera
ページ20に含まれる内容の要旨
+P X K 3 1 9 0 - A 1 The frame from the computer consists of 6 data explanation 1 02 (X ON) start 2 A ~ Z address 3 A: Shaking hands B: asking GW C: asking tare D: asking NW E: asking accumulated times and accumulated weight 4 XRL checking 5 XRL checking 6 03 (X OFF) end XRL = 2 3 ⊕