ページ1に含まれる内容の要旨
Digital Scale
HL-WP Series
HL-1000WP
HL-300WP
HL-3000WP
HL-3000LWP
1WMPD4000754B
ページ2に含まれる内容の要旨
SAFETY PRECAUTIONS All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: A potentially hazardous situation which, if not WARNING avoided, could result in death or serious injury. A potentially hazardous situation which, if not CAUTION avoided, may result in minor or moderate injury. This manual is subject to change without no
ページ3に含まれる内容の要旨
PARTS DESCRIPTION Weighing Platform Display ON/OFF key Turns the scale power on/off. RE-ZERO key Sets display to zero or subtracts weight of container. Spirit level UNITS key (U.S.A. models only) Changes weighing units. Four leveling feet Rubber cap Battery cover AC adapter jack Battery cover lock (Batteries are not included.) Battery compartment STABLE indicator Weighing unit, g Indicates when the reading 012000. kg is s
ページ4に含まれる内容の要旨
PREPARATION Installing Batteries / Connecting The AC adapter Installing Batteries Close the rubber cap CAUTION When replacing batteries, be careful not to apply too much force to the weighing pan. An excessive force could damage the scale. Remove the battery cover and insert six batteries (R6P / LR6 / AA size) into the battery compartment, taking extreme care to that the polarities plus and minus are observed. Be sure to lock the battery cover again after installing the batteries.
ページ5に含まれる内容の要旨
WEIGHING Before weighing Automatic Power-Off Function If the scale is left ON and the stable indicator is displayed, the automatic power-off function turns the power off after approximately 5 minutes (factory setting). To toggle the function disabled/enabled, press the [ON/OFF] key while pressing the [RE-ZERO] key. The scale stores the setting and it will be shown by pressing both the [RE-ZERO] and [UNITS] keys in the weighing mode. (See “CALIBRATION” about the [UNITS] key.) poff0e F
ページ6に含まれる内容の要旨
CALIBRATION When to calibrate Calibration may be required when the scale initially installed, if it is moved a substantial distance, or in accordance with local regulations. This is necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time and use, mechanical deviations can occur. The position of the [UNITS] key for the Calibration The “g” model has no Location of the [UNITS] key [UNITS] key, but the key used to enter cal
ページ7に含まれる内容の要旨
Gravity compensation If you have calibration weights at the capacity of the scale, you can calibrate the scale with the weights instead of compensating for acceleration due to gravity. 2 The scale was calibrated at 9.798 m/sec , at the factory. If the acceleration due to gravity at your location is not same, compensate the scale by adjusting the acceleration due to gravity. (Refer “The Value of Gravity at Various Locations” and “World Map” and find your location value.) 1. Enter ca
ページ8に含まれる内容の要旨
SPECIFICATIONS MODEL HL-1000WP HL-300WP HL-3000WP HL-3000LWP Capacity 1000 x 0.5 g 300 x 0.1 g 3000 x 1 g x 2.2 x 0.001 lb 6.6 x 0.002 lb Resolution 35.28 x 0.02 oz 10.58 x 0.01 oz 105.8 x 0.1 oz 2 lb 3.3 x 0.1 oz 6 lb 9.8 x 0.1 oz Non-linearity ±1g ±0.2g ±2g Repeatability 0.5g 0.1g 1g Span drift ±0.015% / °C TYP (5°C~35°C / 41°F~95°F) Operating temp. -10°C~40°C / 14°F~104°F, Less than 85%RH Display 13 mm / 0.51 inches, 7segment liquid crystal display Display update Approxi
ページ9に含まれる内容の要旨
World Map 8