Waterproof Digital Platform Scale
HV-15KV-WP
HV-60KV-WP
HV-200KV-WP
HW-10KV-WP
HW-60KV-WP
HW-100KV-WP
HW-200KV-WP
WM : PD4000211A
ページ2に含まれる内容の要旨
This is a hazard alert mark. This mark informs you about the operation of the product. Note This manual is subject to change without notice at any time to improve the product. No part of this manual may be photocopied, reproduced, or translated into another language without the prior written consent of the A&D Company. Product specifications are subject to change without any obligation on the part of the manufacture.
ページ3に含まれる内容の要旨
Contents 1. Compliance........................................................................................ 3 1.1.1. Compliance with FCC rules....................................................... 3 1.1.2. Classification of protection provided by enclosures................... 3 2. Outline and Features ......................................................................... 4 3. Unpacking.......................................................................................... 5 3.1. Accesso
ページ4に含まれる内容の要旨
13.1. Preparation (Setting Parameters)................................................ 37 13.2. Operation and Performance (Examples) ..................................... 38 14. Calibration (Adjusting the Scale)...................................................... 39 14.1.1. The Gravity Acceleration Table ............................................... 40 14.2. The Complete Calibration Procedure .......................................... 41 14.2.1. Gravity Acceleration Correction...............
ページ5に含まれる内容の要旨
1. 1. 1. 1. Compliance Compliance Compliance Compliance 1.1.1. 1.1.1. Com Comp pliance w liance wiith FCC th FCC rule rules s 1.1.1. 1.1.1.Com Comp pliance w liance wiith FCC th FCC rule rules s Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection again
ページ6に含まれる内容の要旨
2. 2. 2. 2. O O O Ou u u utlin tlin tlin tline an e an e an e and F d F d F d Fe e e eatur atur atur ature e e es s s s These scales are designed to comply with IP-65 of IEC 529 The HV-WP series is a platform scale with 1/3000 resolution, and has a "triple weighing range" function to select the weighing range. The HW-WP series is a platform scale with 1/10000 resolution. The scales have a fluorescent display so the weighing value can be read in dim light. This type uses the AC power line as a po
ページ7に含まれる内容の要旨
3. 3. 3. 3. Unp Unp Unp Unpacki acki acki ackin n n ng g g g 3. Unpacking HV-WP/HW-WP Series Page 5
ページ8に含まれる内容の要旨
3.1. 3.1. Access Accessori orie es and s and Opti Options li ons list st 3.1. 3.1. Access Accessori orie es and s and Opti Options li ons list st Accessories for the HV-WP series and HW-WP series Products Accessories A HV-15KV-WP A Instruction manual HW-10KV-WP A HV-60KV-WP A HV-200KV-WP 3mm Allen wrench HW-60KV-WP A Instruction manual HW-100KV-WP A HW-200KV-WP Options List Cable or option name Accessories A A OP-02 5m extension loadcell cable Tapping screw M4x10 A OP-03 RS-232C interface/ Relay
ページ9に含まれる内容の要旨
4. 4. 4. 4. Caution Caution Caution Caution 4.1. 4.1. 4.1. 4.1. P P P Pr r r recautions for Insta ecautions for Insta ecautions for Insta ecautions for Installllling ling ling ling the Scale the Scale the Scale the Scale Ground the scale, so that the user will not be subjected to an electric shock. Do not handle the Main power cord with wet hands. The AC plug is not water-resistant. Install it in an area where it does not get wet. Do not install the scale where there is flammable or corrosive ga
ページ10に含まれる内容の要旨
5. 5. 5. 5. Inst Inst Inst Installing alling alling alling the S the S the S the Sc c c cale ale ale ale This procedure includes all of the steps for installing the HV-WP series and HW-WP series. Therefore, on some products, there are some unnecessary steps. Step 1 Connect the indicator unit to the pole with the accesory knobs and rubber washers. Step 2 Take the base unit and pole out, taking care that the load-cell cable is not pulled. Step 3 Put the weighing pan on the base unit. Step 4 Insert
ページ11に含まれる内容の要旨
5.1. 5.1. 5.1. 5.1. Remov Remov Remov Removiiiing the ng the ng the ng the pole pole pole pole Caution Remove the main power plug from the receptacle before removing the pole. When removing the loadcell cable, do not pull the loadcell cable connector forcibly and do not pull on the wires of the cable. Do not bend the cable forcibly. Avoid dust, static electricity and high humidity (or drops) because the inside of the indicator unit is very sensitive. Procedure Step 1 Remove the power plug from t
ページ12に含まれる内容の要旨
Step 8 Removing the pole base from the base unit, requires the following allen wrench. HV-15KV-WP, HV-200KV-WP, HV-60KV-WP, HW-100KV-WP, HW-10KV-WP, HW-200KV-WP HW-60KV-WP 5mm Allen wrench 6mm Allen wrench Step 9 Wind the cable through the ferrite core two times. Affix the cable to the rear cover using the cable clamp. Step 10 Connect the cable to the connnector. Close the rear cover. Step 11 Confirm the accuracy of the scale. 5. 1. Removing the ploe Page 10 HV-WP/HW-WP Series
ページ13に含まれる内容の要旨
6. 6. 6. 6. Na Na Na Name me me mes s s s 6.Names HV-WP/HW-WP Series Page 11
ページ14に含まれる内容の要旨
6.1. 6.1. 6.1. 6.1. Display and S Display and S Display and S Display and Sy y y ymbols mbols mbols mbols Display and Symbols Meaning A A Stability mark. When the current weighing value is stable, this mark is A displayed, indicating a condition where the value is A readable. A A Zero point mark. A With nothing on the weighing pan and pressing the ZERO switch, this mark is displayed. The zero point is a A fundamental starting point to weigh anything. A A Net mark. Pressing the TARE switch,
ページ15に含まれる内容の要旨
Display and Symbols Meaning A A Example. Storing the unit mass of the counting mode. A This is a display of zero point for the counting mode and A uses 20 pieces for the registration. A A Example. Storing the unit mass of the counting mode. A The sign "-" means "weighing value is not zero". A Sample number is 10 pieces. A A Example. Percentage mode. A This mode uses the registered 100% mass, and converts A the weighing value to a percentage. The unit is % . A A Example. Display of the function
ページ16に含まれる内容の要旨
Display and Symbols Meaning A A An error where the weighing value is unstable due to A drift, vibration or other, when turning on the scale. Check around the weighing pan. A Check the connection of load cell cable. A A Remove anything that may be on the weighing pan. Check around weighing pan. A Perform zero point calibration of the scale. A A Error indication. A Refer to "19 Maintenance". A A Accumulated data count. A A Total mass value of the accumulated data. A A Comparator function, display
ページ17に含まれる内容の要旨
Display and Symbols Meaning A A Set switch. Turns the comparator on/off. (Refer to f6 ) A Counting mode, it is used to enter the mode to store the A unit mass. A Percentage mode, it is used to enter the mode to store the A 100% mass. A The full/dribble batch function, it is used as a start switch. For the preset tare and selecting a calibration mass, it is A used to select a figure. A A Mode switch. Changing the current unit. A While setting modes, this switch is used for " storing a A parameter
ページ18に含まれる内容の要旨
7. 7. 7. 7. B B B Ba a a asi si si sic Ope c Ope c Ope c Oper r r ration ation ation ation 7.1. 7.1. 7.1. 7.1. Tu Tu Tu Turing ring ring ring the the the the Sc Sc Sc Scale on/off and Weighing ale on/off and Weighing ale on/off and Weighing ale on/off and Weighing Step 1 Ground the scale using the earth terminal. Step 2 Place nothing on the weighing pan. Step 3 Confirm that local voltage and receptacle type adapt to your scale. Step 4 The scale turns on/off using the ON/OFF switch alternately.
ページ19に含まれる内容の要旨
7.2. 7.2. 7.2. 7.2. Tare Tare Tare Tare (A (A (A (And nd nd nd Ne Ne Ne Net t t t Di Di Di Disp sp sp splay) lay) lay) lay) "Tare" is used to cancel the mass of a container, receptacle, case, bag, etc. which is put on the weighing pan to contain the item to be weighed. Caution Using a tare value reduces the weighing range. The current tare value is reset by pressing the ZERO switch or turning the scale off. (Reset value is zero.) The preset tare value must be within the minimum weighing range
ページ20に含まれる内容の要旨
7.3. 7.3. 7.3. 7.3. We We We Weighing ighing ighing ighing Ran Ran Ran Rang g g ge f e f e f e fo o o or r r r the HV- the the the HV- HV- HV-W W W WP series P series P series P series This is the function to select a weighing range for the HV-WP series. The mass value is displayed within a selected range. There is the automatic range (f2 0) and manual range (f2 1) using the RANGE switch. Operation and Performance Function table Meaning and purpose A A Automatic range The weighing range change