ページ1に含まれる内容の要旨
Precision Health Scale
UC-324NFC
Instruction Manual
1WMPD4002355B
ページ2に含まれる内容の要旨
Contents Before Use Precautions ........................................................................................................ 1 Scale Components............................................................................................. 2 Display Symbols ................................................................................................ 3 Automatic Power-Off Function ........................................................................... 3 Near Field Communicat
ページ3に含まれる内容の要旨
Scale Components SET Switch Communication Area Front Battery Compartment Handle Scale Leg Display Ready/Stable Symbol Back Unit Battery Indicator Accessories Instruction manual Batteries Add-on feet 2
ページ4に含まれる内容の要旨
Display Symbols Symbols Name Description This symbol is displayed when the Ready/Stable symbol measurement display is stable. Battery indicator The normal battery power indicator with charge remaining ↓ Low battery indicator If this symbol is displayed, replace all four batteries with new ones. WEEE label CE mark Automatic Power-Off Function The scale has an “Automatic power-off” function. If “0.00 kg /0.0 lb” and the Ready/ Stable symbol are displayed fo
ページ5に含まれる内容の要旨
Installing (or Replacing) the Batteries Caution Insert each battery with its positive (+) and negative (-) terminals properly aligned with the corresponding symbols in the battery compartment. Improper installation of the batteries may cause battery leakage. Replace all four batteries with new ones, when the symbol is displayed. Do not mix new and used batteries. It may cause damage to the scale or shorten the battery life. The symbol does not appear when the batteries are complet
ページ6に含まれる内容の要旨
Setting the Unit Setting the unit manually Press the SET switch. 1. Confirm that the scale is turned off. Press the SET switch. The scale beeps and displays the unit currently set. SET switch 2. Press the SET switch to select the unit. 3. After three seconds of non-operation, the scale confirms the selected unit with two beeps, displays “ ” and automatically turns off. Setting the unit by the communication device (Only for devices that rewriting of the unit information is e
ページ7に含まれる内容の要旨
Measuring Your Weight Using the NFC Function After measurement, the communication device receives the data. 1. Confirm that the scale is turned off. Turn off Step on the scale gently and stand still Step on the scale. during the measurement. The scale turns on, displays all of the display segments. 2. Wait the finish of the measurement. The process of the measurement is In processing of displayed with segment “ ”. measurement. 3. Step off the scale when the stable symbol is displ
ページ8に含まれる内容の要旨
Maintaining the Scale Clean the scale with a soft dry cloth or a cloth moistened with water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean the scale. Remove the batteries from the battery compartment, when the scale is not going to be used for a long time. Before Requesting Service Problems Possible Reason / Corrective Action is displayed. Exceeds the maximum capacity. is displayed Exceeds the maximum capacity. is displayed. Do
ページ9に含まれる内容の要旨
Caution on Using the NFC Function The scale has an NFC Forum Type 3 Tag wireless interface module built in. When the scale is used near wireless communication devices which use the same frequency as that of the scale (13.56 MHz) or use its harmonic frequencies, electromagnetic interference may occur. In that case, turn off the devices that are not in use, or place the devices 1 meter or more away from the scale. Specifications Type UC-324NFC Maximum capacity 150 kg / 330 lb Minim
ページ10に含まれる内容の要旨
1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131 U.S.A. Telephone: [1] (408) 263-5333 Fax: [1] (408)263-0119