ページ12に含まれる内容の要旨
Philips 1881 Route 46 West Ledgewood, NJ 07852 800-852-4312 www.Philips.com Made in China © 2007 Part # OMSPP4200-210-220_1007
ページ1に含まれる内容の要旨
Owner’s Manual & Warranty
Models SPP00WA/7 / SPP0WA/7 / SPP0WA/7
ページ2に含まれる内容の要旨
Introduction TM Thank you for choosing Philips model SPP4200 / SPP4210 / SPP4220 Theatre Director Advanced Surge Protector. With Theatre Director, the home theater surge protector is moved off the floor behind the A/V cabinet up to the shelf or rack that holds all of the other components. This provides the ultimate in convenience when connecting all of the components. In addition to the convenience, Theatre Director is also technologically superior to standard surge protectors. With fea
ページ3に含まれる内容の要旨
TM V3 Technology For the more common everyday transient surges and spikes that are most commonly caused by household appliances turning on and off, Theatre Director uses an advanced type of MOV (metal oxide varistor). This new type of MOV provides greater capacity to absorb surges and spikes, as well as better energy dissipation. The result is a more efficient, longer lasting surge protector. Clear Connect Power Conditioning The electrical current running through your home is filled with im
ページ4に含まれる内容の要旨
RJ11 Modem/Phone Line Protection As with incoming coaxial or RJ45 networking lines, surges can also enter your system through TM standard RJ11 phone lines. Some A/V components, such as digital satellite receivers, DVRs, TiVo , etc., require connection to a phone line. Theatre Director will protect your equipment from surges coming through this line too. In addition, should your system incorporate more than one component that requires a phone line connection, we included a 1-in / 2-out pho
ページ5に含まれる内容の要旨
Feature Chart Model SPP00 SPP0 SPP0 s-OV Technology √ √ √ TM V3 Technology √ √ √ ClearConnect Technology √ √ √ Always-on AC Outlets 2 2 2 Switched AC Outlets 6 8 10 Total AC Outlets 8 10 12 Coaxial Cable Protection 2 sets 3 sets 4 sets RJ45 Network Protection n/a √ √ RJ11 Modem/Phone Protection √ √ √ Grounding Lug √ √ √ Resettable Circuit Breaker √ √ √
ページ6に含まれる内容の要旨
Front Panel Indicators A series of intelligent LED indicators on the front panel of Theatre Director keep you informed of the power status at all times. The red light lets you know that the surge protection function is ready in the event it is needed. The green light lets you know that your electrical system is wired and grounded properly. The range of blue lights let you know what your current input voltage level is. The main power switch, also located on the front panel, turns power on a
ページ7に含まれる内容の要旨
Specifications Model SPP00 SPP0 SPP0 Maximum Input Voltage (VAC) 125 Nominal Input Frequency (Hz) 60 Maximum Output Power (Watts) 1875 Maximum Line Current (Amps) 15 AC Line Clamping Voltage 330 Energy Dissipation (Joules) 4320 5400 6480 EMI/RFI Noise Filtering (dB) 85 Maximum Transient Current (Amps; all lines) 288,000 360,000 432,000 Transient Response Time (nanoseconds) <1 <1 <1 Power Cord Length 8ft. Coax Clamping Voltage 75 Coax Attenuation <1.0dB to 2.5 GHz Phone (RJ11) Clamping V
ページ8に含まれる内容の要旨
Warnings TO PREVENT THE RISK OF ELECTRICAL SHOCK OR FIRE: • This product is designed for indoor use only. • Do not use in wet or damp areas exposed to moisture. • Not recommended for use with aquariums. High humidity environments can cause corrosion and surface contamination, which may result in heat buildup and/or arcing between plug blades. • Device must be properly connected to a grounded three-prong receptacle. • Do not daisy chain the unit with another extension cord or multiple o
ページ9に含まれる内容の要旨
Connected Equipment Warranty The Customer’s exclusive remedy under any warranty, including this express Connected Equipment Warranty or any applicable implied warranty, and Philips’ sole obligations, are as follows for “Connected Equipment”: If, (a) the Product purchased and owned by the Customer is defective in materials or workmanship under the Limited Product Warranty, or any applicable implied warranty; (b) the stated Limited Product Warranty requirements have been met; and (c) none of
ページ10に含まれる内容の要旨
Agreed Damage Amount The Agreed Damage Amount for all items of the Customer’s Connected Equipment shall be the lesser of the amount determined under clause (a) or (b) below, reduced by any amounts described in clause (c) below. a) The fair market value of the equipment shall be the current value of the equipment specified in the most recent edition of Orion Blue Book (by Orion Research Corporation, Roger Rohrs Publisher) or a valuation as determined by Philips in its reasonable discretion.
ページ11に含まれる内容の要旨
OTHER EXCLUSIONS Philips does not cover or undertake liability in any event for any of the following: . Loss of or damage to data, records or software; restoration of data or records; or re-installation of software. . Any amount of money that the Customer may recover from other sources regarding the Connected Equipment Warranty; including insurance, other warranty or extended warranty coverage. The obligations of Philips hereunder, including payment of Agreed Damage Amount, shall be re