ページ1に含まれる内容の要旨
T1-Titanium
THE SPRAY GUN PEOPLE
FOR PRODUCT INFORMATION CALL:
Non-HVLP Spray Gun
1-800-742-7731
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Maximum Fluid and Air Inlet Pressure:100 psi (0.7 MPa, 7 bar)
II 2 G
Gun Part Needle/Nozzle Air Consumption
No. Size (CFM) Recommended Usage
5430 1.2 mm 11* Pressure feed production
5435 1.8 mm 13.8* Medium solids, colors and clears
* At 50 psi (345 kPa, 3.4 bar)
SHARPE MANUFACTURING COMPANY •
ページ2に含まれる内容の要旨
WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). Keep work area free of debris, including solvent, rags and gasoline. Do not plug or unplug power cords or turn lights on or off when flammable fumes a
ページ3に含まれる内容の要旨
T1-TITANIUM NON-HVLP SPRAY GUN Flushing Setup Check that your shop air provides adequate air flow. WARNING Use a minimum 5/16 in. ID air supply hose. Set air and fluid pressure regulator according to paint man- Read warnings, page 2. ufacturer’s recommendation for conventional equipment. Do not exceed 100 psi (0.7 MPa, 7 bar). Flush before using the equipment, before changing colors, and when you are done spraying. Use solvent that is compatible with Make sure no air restrictions,
ページ4に含まれる内容の要旨
T1-TITANIUM NON-HVLP SPRAY GUNS Cleaning Nozzle and Air Cap Cleaning and Maintenance CAUTION WARNING Trigger gun and use nozzle removal tool 41160 when- ever you tighten or remove nozzle to avoid damaging needle seat and nozzle. Follow Pressure Relief Procedure when you stop spraying Do not use metal tools to clean air cap holes as this may and before cleaning, checking, or servicing equipment. Read scratch them and distort the spray pattern. warnings, page 2. To clean the air cap and no
ページ5に含まれる内容の要旨
T1-TITANIUM NON-HVLP SPRAY GUN Troubleshooting WARNING Follow Pressure Relief Procedure, page 3, before troubleshooting or servicing. Read warnings, page 2. Problem Cause Solution Normal pattern No action necessary Right Dirty or damaged air cap or fluid nozzle. Rotate air cap 180°. If pattern follows air cap, problem is in air cap. Clean and inspect. See page 4. If pattern is not corrected, replace air cap. If pattern does not follow the air cap, the problem is with the Wrong fluid nozzle.
ページ6に含まれる内容の要旨
T1-TITANIUM NON-HVLP SPRAY GUNS Parts 6 310584D 17 7* 8* 3* 8* 17d* 17c* 17b* 17a* 20 12 30†* 31* 32*† 33*† 34*† 35 15* 19 36 37 4* 10 REF 38 12 2d* 2c* 2b* 2e* 2f* 2a* 9 13 14* 16 2 1 6 Ref. Ref. No. Part No. Description Qty. No. Part No. Description Qty. 17 41122 Width Control Assembly; Includes 17a-17d 1 1 41141 Gun Handle 1 17a* 16175 Retaining Ring 1 2 41120 Air Valve Assembly; Includes 2a-2f 1 17b* 38120 O-Ring 1 2a* 26032 Packing Nut 1 17c 26066 Body 1 2b* 25066 Air Valve 1
ページ7に含まれる内容の要旨
T1-TITANIUM NON-HVLP SPRAY GUN 7 310584D
ページ8に含まれる内容の要旨
15 ft. to 20 ft. Main Air Line 1 in. Pipe Minimum A Dryaire Membrane or Desiccant Air Drying Systems at Air Control Unit Paint Booth or Air Filter Union Compressor Model 707C Air Out C B Oil Coalescer Drain Leg Model 707F Air Filter Ball Valve Refrigerated Air In Air Dryer Flexible Hose Between com- D E pressor and Main Air Line Ref. Letter Description Model No. Sharpe 606 U06710 A Sharpe 606A U06720 Sharpe 606B 6730 Sharpe 880A 6950 Sharpe F88 8130 707C 693