WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS USER MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE, INJUR
ページ3に含まれる内容の要旨
TABLE OF CONTENTS SPECIAL NOTES ....................................................................... 4 Disposal of Equipment and Accessories ...............................................................................6 SECTION 1—GENERAL GUIDELINES ............................................. 7 Operating Information ..............................................................................................................8 Maintenance.....................................................
ページ4に含まれる内容の要旨
SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for definitions of the signal words. SIGNAL WORD MEANING Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious DANGER injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious WARNING injury.
ページ5に含まれる内容の要旨
SPECIAL NOTES CAUTION Within the US: “Caution: Federal law restricts this device to sale or rental by or on order of a physician, or any other practitioner licensed by the law of the State in which he/she practices to use or order the use of this device.” can be The use of oxygen therapy in certain circumstances hazardous and seeking medical advice before using this device is advisable. Invacare recommends an alternate source of supplemental oxygen in the event of a power outage, alarm co
ページ6に含まれる内容の要旨
SPECIAL NOTES Disposal of Equipment and Accessories This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/CE. This product may contain substances that could be harmful to the environment if disposed of in places (landfills) that are not appropriate according to legislation. Follow local governing ordinances and recycling plans regarding disposal of the device or components normally
ページ7に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES In order to ensure the safe installation, assembly and operation of the transportable oxygen concentrator these instructions MUST be followed. WARNING This section contains important information for the safe operation and use of this product. DANGER Risk of electric shock. DO NOT disassemble. Refer servicing to qualified service personnel. No user serviceable parts. TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE OR INJURY TO P
ページ8に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES DANGER Avoid creation of any spark near medical oxygen equipment. This includes sparks from static electricity created by any type of friction. DO NOT move or relocate concentrator by pulling on the cord. A product should NEVER be left unattended when plugged in. Make sure the transportable oxygen concentrator is Off when not in use. Outdoor use of the transportable oxygen concentrator MUST be conducted with battery power only. Operating Information The tran
ページ9に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES The transportable oxygen concentrator is designed only to be used with a humidifier while using continuous flow mode. Use of this device with a humidifier in pulse flow mode may impair performance and/or damage the equipment. When your automobile is turned Off, disconnect the car accessory power supply and remove the transportable oxygen concentrator from the automobile. NEVER allow the transportable oxygen concentrator to be stored in a very hot or cold autom
ページ10に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES Maintenance The transportable oxygen concentrator was specifically designed to minimize routine preventive maintenance. Only professionals of the healthcare field or persons fully conversant with this process such as factory trained personnel should perform preventive maintenance or performance adjustments on the oxygen concentrator. Radio Frequency Interference This equipment has been tested and found to comply with EMC limits specified by IEC/EN 60601‐1‐2. T
ページ11に含まれる内容の要旨
SECTION 2—PACKAGING AND HANDLING SECTION 2—PACKAGING AND HANDLING Unpacking 1. Check for any obvious damage to the carton or its contents. If damage is evident, notify the carrier, or your local dealer. 2. Remove all loose packing from the carton. 3. Carefully remove all the components from the carton. The transportable oxygen concentrator packaging contains the following items (as shown below). If any parts are missing, please contact your equipment provider. • Transportable oxygen concen
ページ12に含まれる内容の要旨
SECTION 3—TECHNICAL DESCRIPTION SECTION 3—TECHNICAL DESCRIPTION The Invacare transportable oxygen concentrator is to be used by patients with respiratory disorders who require supplemental oxygen. The device is not intended to sustain or support life. The oxygen concentration level of the output gas ranges from 87% to 95.6%. The oxygen is delivered to the patient through the use of a nasal cannula. The transportable oxygen concentrator provides two modes of operation; pulse flow and conti
ページ13に含まれる内容の要旨
SECTION 4—FEATURES SECTION 4— FEATURES Please review the figures below to familiarize yourself with the locations of the transportable oxygen concentrator features and controls. RED GREEN YELLOW Indicator Indicator On/Off Button Indicator LCD Display Carry Handle Increase Button Mode/Return/ Highlight Button External Power Input Connector Decrease Button Air Intake and Filter Oxygen Outlet Port and HEPA Filter NOTE: The battery pack is not shown. This item is located on the back si
ページ14に含まれる内容の要旨
SECTION 5—TYPICAL PRODUCT PARAMETERS SECTION 5—TYPICAL PRODUCT PARAMETERS Direct Current Type BF equipment Attention - Consider Accompanying Documents DO NOT smoke No open flame Class II, Double Insulation Power On/Off DO NOT dispose of in household waste Recycle DO NOT use oil or grease Keep dry in transport or storage Protected against dripping water in upright position IPX1 (AC and DC power input) Protected against dripping water in upright and tilted IPX2 positions (battery power only) No
ページ15に含まれる内容の要旨
SECTION 5—TYPICAL PRODUCT PARAMETERS POWER INPUT: 24 VDC @ 7.5 Amp or 11-16 VDC @ 10.0 Amp max (12.6 VDC Nom.) EXTERNAL POWER SUPPLY INPUT: AC POWER SUPPLY: 120 VAC, 50/60 Hz @ 2.5 amps 230 VAC, 50/60 Hz @ 1.25 amps DC POWER SUPPLY: 11-16 VDC, (12.6 VDC Nom. @ 10.0 Amp max) SOUND LEVEL: < 40 dBA weighted @ 2 LPM continuous and all pulse settings (1-5) ALTITUDE: Up to 10,000 ft (3046 m) above sea level Titration recommended for use above 10,000 ft (3046 m) OXYGEN CONCENTRATION:* 87% to 95.6%
ページ16に含まれる内容の要旨
SECTION 5—TYPICAL PRODUCT PARAMETERS MAXIMUM RECOMMENDED 3.0 LPM FLOWRATE WITH 7KPA (1.01 PSI) BACKPRESSURE: PRESSURE RELIEF 20 psi ± 5 psi (137.8 kPa ± 34.5 kPa) ACTIVATION: MAX OUTLET PRESSURE @ 12.0 psig 3.0 LPM CONTINUOUS: DIMENSIONS: 16.5 in high x 11 in wide x 8 in deep (41.9 cm (WITHOUT CART) high x 27.9 cm wide x 20.3 cm deep) WEIGHT: < 20 lbs (9.09 kg) (UNIT WITHOUT CART) BATTERY DURATION: Pulse Mode Continuous Mode (TIMES ARE APPROXIMATE) Setting 1 = 4.5 hrs Setting 0.5 LPM = 4.5 h
ページ17に含まれる内容の要旨
SECTION 5—TYPICAL PRODUCT PARAMETERS EXTENDED TEMPERATURE RANGE: (USING BATTERY) OPERATING TEMPERATURE: 95°F to 104° (35°C to 40°C) Pulse Mode Continuous Mode Settings 1, 2 and 3 = 0.5 thru 1.5 LPM = unlimited use unlimited use Setting 4 = 45 2.0 thru 2.5 LPM = 45 minutes minutes Setting 5 = 30 3.0 LPM = minutes 30 minutes Regulatory Listing ETL certified complying with: EN 55011: 1998 CISPR 11: 2003 IEC 60601-1: 2005 IEC 60601-1-2: 2.1 Ed. IEC 61000-3-2: 2005 IEC 61000-3-3: 2005 UL 60601-1
ページ18に含まれる内容の要旨
SECTION 6—OPERATING INSTRUCTIONS SECTION 6—OPERATING INSTRUCTIONS Location WARNING NEVER block the air opening of the product or place it on a soft surface, such as a bed or couch, where the air opening may be blocked. Keep the openings free from lint, hair and the like. Keep unit at least 3 in (7.6 cm) away from walls, draperies, furniture, and the like. Locate and position the transportable oxygen concentrator in a well ventilated space so that the air intake and the air exhausts are n
ページ19に含まれる内容の要旨
SECTION 6—OPERATING INSTRUCTIONS Powering the Transportable Oxygen Concentrator WARNING Use only Invacare specified power supplies with the transportable oxygen concentrator. Use of other non approved power supplies with the transportable oxygen concentrator can cause damage and/or injury and will void the warranty. When using the DC Power Cable to either operate or charge the transportable oxygen concentrator, the car/boat/motor home engine should be operating. NOTE: The battery module
ページ20に含まれる内容の要旨
SECTION 6—OPERATING INSTRUCTIONS 2. To operate from external power (AC or DC) please follow the steps below: A. Turn off the transportable oxygen concentrator. B. Connect the external power supply (DC power cable or AC power adapter) to the transportable oxygen concentrator. C. Perform one of the following: •Plug the other end of the AC power adapter into a wall outlet. •Plug the other end of the DC power cable into the auto accessory outlet and start the engine. D. Turn the transportable oxy