Operator's Manual
™
Platinum
Oxygen Concentrators Standard,
with ® ®
/SensO and HomeFill
2
Model IRC5LXAW
Model IRC5LXO2AW
Model IRC5LXO2AWQ
Model IRC9LXO2AWQ
Dealer: This manual must be given to the
end user.
User: Before using this concentrator, read
this manual and save for future reference.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com
0434
ページ2に含まれる内容の要旨
WARNING WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL PERSONNELBEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWI
ページ3に含まれる内容の要旨
TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ...............................................5 RECYCLING INFORMATION .............................6 SECTION 1—GENERAL GUIDELINES .....................7 Maintenance.......................................................................................... 9 Radio Frequency Interference.......................................................... 9 To Reduce The Risk Of Burns, Electrocution, Fire Or Injury To Persons ................................
ページ4に含まれる内容の要旨
TABLE OF CONTENTS Routine Maintenance........................................................................27 SECTION 7—TROUBLESHOOTING GUIDE ............31 LIMITED WARRANTY .................................... 33 ™ Platinum 4 Part No 1134866
ページ5に含まれる内容の要旨
SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for definitions of the signal words. SIGNAL WORD MEANING Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious DANGER injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or WARNING serious injury
ページ6に含まれる内容の要旨
RECYCLING INFORMATION RECYCLING INFORMATION This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/CE. This product may contain substances that could be harmful to the environment if disposed of in places (landfills) that are not appropriate according to legislation. The ʹcrossed out wheelie binʹ symbol is placed on this product to encourage you to recycle wherever possible. Please b
ページ7に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product. In order to ensure the safe installation, assembly and operation of the Platinum concentrator these instructions MUST be followed. CAUTION “Caution: Federal law restricts this device to sale or rental by or on order of a physician, or any other practitioner licensed by the law of the governmental agency in which he
ページ8に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES WARNINGS The use of oxygen therapy requires that special care be taken to reduce the risk of fire. Any materials that will burn in air, and some that will not, are easily ignited and burn rapidly in high concentrations of oxygen. For safety concerns, it is necessary that all sources of ignition be kept away from the product and preferably out of the room in which it is being used. NO SMOKING signs should be prominently displayed. A spontaneous and violent ign
ページ9に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES Fill humidifier with water to the level shown by the manufacturer. DO NOT overfill. Keep unit at least 7.5 cm (3 in) away from walls, draperies, furniture, and the like. Invacare recommends that Crushproof oxygen tubing (supplied by Invacare) be used with this product and NOT exceed 15.2 m (50 ft) in length. Recommended use for Platinum 9 is up to 15.2 m (50 ft) in length of high flow tubing. Maintenance The Invacare Oxygen Concentrator was specifically designe
ページ10に含まれる内容の要旨
SECTION 1—GENERAL GUIDELINES DO NOT reach for product that has fallen into water. Unplug IMMEDIATELY. This device is to be used only in accordance with the prescription of a physician and this Owners Manual. If at any time the patient or attendant conclude that the patient is receiving an insufficient amount of oxygen, the supplier and/or physician should be contacted IMMEDIATELY. No adjustments should be made to the flowrate unless prescribed by a physician. Close supervision is necessar
ページ11に含まれる内容の要旨
SECTION 2—FEATURES SECTION 2—FEATURES FRONT VIEW Oxygen Purity and Fault Indicator Oxygen Outlet Lights (SensO model)/Fault and 2 Power Indicator Lights (LX model) Flowmeter Power Switch Circuit Breaker Elapsed Time Meter (Hour Meter) Cabinet Filter (one of two shown) *NOTE: This outlet fitting is to be used only for filling oxygen cylinders with the HomeFill home oxygen compressor. The outlet fitting does not affect concentrator performance. Refer to the HomeFill ownerʹs manual, part num
ページ12に含まれる内容の要旨
SECTION 3—SHIPPING AND HANDLING SECTION 3—SHIPPING AND HANDLING NOTE: For this procedure, refer to FIGURE 3.1 on page13. Before you install and operate the concentrator, please refer to Platinum Series Ownerʹs Manual. The Platinum concentrator should ALWAYS be kept in the upright position to prevent cabinet damage while being transported. The shipping container has been designed to assure maximum protection of the concentrator. If the concentrator is to be reshipped by common carrier, it
ページ13に含まれる内容の要旨
SECTION 3—SHIPPING AND HANDLING FIGURE 3.1 Unpacking Part No 1134866 13 Platinum™
ページ14に含まれる内容の要旨
SECTION 4—TYPICAL PRODUCT PARAMETERS SECTION 4—TYPICAL PRODUCT PARAMETERS Regulatory EN/IEC 60601-1 Listing: Alternating Current Type BF equipment Unit running Unit not running Attention - Consider Accompanying Documents DO NOT smoke Class II, Double Insulation Electrical Requirements: 230 VAC ± 10% (253 VAC/207 VAC), 50 Hz Rated Current Input: 1.4 A (IRC5LXO2AWQ) 2.0 A (IRC5LXAW, IRC5LXO2AW) 2.1 A (IRC9LXO2AWQ) Sound Level: 39.5 dB Average (IRC5LXO2AWQ) 44 dB Average (IRC5LXAW, IRC5LXO2AW) 50
ページ15に含まれる内容の要旨
SECTION 4—TYPICAL PRODUCT PARAMETERS *Oxygen Output IRC5LXAW, IRC5LXO2AW and Concentration Levels: IRC5LXO2AWQ All 5LXO2AWQ/5LXAW/ 93% minimum at 1 to 3 L/min. 5LXO2AW/9LXO2AWQ 91% minimum at 4 L/min. models 87% minimum at 5 L/min. (maximum * (Stated concentration levels recommended flow) achieved after initial warm-up IRC9LXO2AWQ period (approximately 30 92% minimum at 1 to 2 L/min. minutes). 91% minimum at 8 L/min. 87% minimum at 9 L/min. 93% minimum at 3 to 7 L/min. Maximum Outlet Press
ページ16に含まれる内容の要旨
SECTION 4—TYPICAL PRODUCT PARAMETERS Change in maximum 0.7 L/min. recommended flow when back pressure of 7k Pa is applied: Filters: Cabinet (2), Outlet HEPA and Compressor Inlet. Safety System: Current overload or line surge shutdown. High temperature compressor shutdown. High Pressure Alarm w/compressor shutdown. Low Pressure Alarm w/compressor shutdown. Battery Free Power Loss Alarm. SensO Oxygen System (SensO Model) Low 2 2 Flow Alarm. Width: 46.7 cm ± 1 cm (18 3/8 in ± 3/8 in) He
ページ17に含まれる内容の要旨
SECTION 4—TYPICAL PRODUCT PARAMETERS Regulatory Listing: IRC5LXAW/IRC5LXO2AW/ IRC5LXO2AWQ/IRC9LXO2AWQ ETL tested as complying with: EN55011 EN61000-3-2 EN61000-3-3 IEC 60601-1, A1, A2 IEC 60601-1-2 IRC5LXO2AW, IRC5LXO2AWQ, IRC9LXO2AWQ Models Only ISO8359 MDD CE marked models: IRC5LXO2AW, IRC5LXO2AWQ, IRC9LXO2AWQ Electrical: No extension cords. Placement: No closer than 7.5 cm (3 inches) from any wall, furniture, draperies, or similar surfaces. Tubing: IRC5LXAW, IRC5LXO2AW, IRC5LXO2AWQ 2.1 m
ページ18に含まれる内容の要旨
SECTION 4—TYPICAL PRODUCT PARAMETERS SENSO INDICATORS 2 LABEL STATUS INDICATOR LIGHTS SYMBOL (LED) SYSTEM OKAY GREEN Indicator Light O over 85% (± 2%) O 2 2 O Between 73% (± 3%) YELLOW Indicator light 2 A. YELLOW Solid to 85% (±2%) B. YELLOW Flashing Sensor Failure Call a qualified technician. SYSTEM FAILURE RED Indicator Light O Below 73% (±3%) Refer to Troubleshooting Guide 2 on page 31. LX INDICATORS LABEL STATUS INDICATOR LIGHTS SYMBOL (LED) SYSTEM OKAY GREEN Indicator Light I/O SYSTEM F
ページ19に含まれる内容の要旨
SECTION 5—OPERATING INSTRUCTIONS SECTION 5—OPERATING INSTRUCTIONS Introduction Your oxygen concentrator is intended for individual use in the home. It is an electronically operated device that separates oxygen from room air. It provides high concentration of oxygen directly to you through a nasal cannula. Clinical studies have documented that oxygen concentrators are therapeutically equivalent to other types of oxygen delivery systems. Your provider will show you how to use your oxygen c
ページ20に含まれる内容の要旨
SECTION 5—OPERATING INSTRUCTIONS Recommended Guidelines for Optimum Performance Temperature: (10°C - 35°C) 50°F - 95°F Electrical: No extension cords. Placement: No closer than 7.5 cm (3 in) from the wall, furniture, draperies, or similar surfaces. Tubing and Cannula: IRC5LXAW, IRC5LXO2AW, IRC5LXO2AWQ 2.1 m (7 ft) cannula with a maximum 15.2 m (50 ft) of Crush-Proof Tubing (DO NOT pinch). IRC9LXO2AWQ Recommended use up to 15.2 m (50 ft) high flow tubing with high flow cannula at all flow