ページ1に含まれる内容の要旨
UserManual
80E01,80E02,80E03,80E04&80E06
ElectricalSampling Modules
071-0434-05
This document applies to firmware version 1.00
and above.
www.tektronix.com
ページ2に含まれる内容の要旨
Copyright© Tektronix. All rightsreserved. Licensed software productsare owned by Tektronix or itssubsidiariesor suppliers, and are protected by national copyright lawsand international treaty provisions. Tektronix productsare covered by U.S. and foreign patents, issued and pending. Information in thispublication supercedes that in all previously published material. Specificationsand price change privilegesreserved. TEKTRONIXand TEKare registered trademarksof Tektronix, Inc. ContactingTektronix T
ページ3に含まれる内容の要旨
Warranty2 Tektronix warrantsthat thisproduct will be free from defectsin materialsand workmanship for a period of one (1) year from the date of shipment. If any such product provesdefective during thiswarranty period, Tektronix, at itsoption, either will repair the defective product without charge for partsand labor, or will provide a replacement in exchange for the defective product. Parts, modulesand replacement productsused by Tektronix for warranty work may be newor reconditioned to like new
ページ4に含まれる内容の要旨
ページ5に含まれる内容の要旨
TableofContents GeneralSafetySummary ................................... iii EnvironmentalConsiderations............................... v Preface................................................... vii Manual Structure ................................................ vii RelatedDocumentation ........................................... vii GettingStarted............................................ 1 Product Description .............................................. 2 OptionsandAccessories.........
ページ6に含まれる内容の要旨
TableofContents ListofFigures Figure1:Samplingmoduleblock diagram..................... 3 Figure2:Samplingmodule, 80E04shown ..................... 3 Figure3:Samplingmodulecompartments..................... 6 Figure4:Installingasamplingmodule........................ 8 Figure5:Samplingmodule, 80E04shown ..................... 12 Figure6:VerticalSetup dialogbox ........................... 14 Figure7:Simplified schematicdiagramofstep generator-positivepolarity .............................. 18 Figure8:
ページ7に含まれる内容の要旨
GeneralSafetySummary Review thefollowing safety precautions to avoid injury and prevent damageto this product orany products connected to it. To avoid potential hazards, usethis product only as specified. Onlyqualified personnel should perform serviceprocedures. Whileusing this product, you may need to access otherparts ofthesystem. Read theGeneral SafetySummaryin othersystem manuals forwarnings and cautions related to operating thesystem. ToAvoidFireor GroundtheProduct.This product is indirectl
ページ8に含まれる内容の要旨
General Safety Summary SymbolsandTerms TermsinthisManual.Theseterms may appearin this manual: WARNING.Warning statements identifyconditions or practices that could result in injuryor loss of life. CAUTION.Caution statements identifyconditions or practices that could result in damageto this product or other property. TermsontheProduct.Theseterms may appearon theproduct: DANGER indicates an injury hazardimmediately accessibleas you read the marking. WARNING indicates an injury hazard notimmediatel
ページ9に含まれる内容の要旨
EnvironmentalConsiderations This section provides information about theenvironmental impact ofthe product. ProductEnd-of-Life Observethefollowing guidelines when recycling an instrument orcomponent: Handling EquipmentRecycling. Production ofthis equipment required theextraction and useofnatural resources. Theequipment may contain substances that could be harmful to theenvironment orhuman health ifimproperly handled at the product’s end oflife. In orderto avoid releaseofsuch substances into the e
ページ10に含まれる内容の要旨
Environmental Considerations vi 80E00 Electrical Sampling Modules UserManual
ページ11に含まれる内容の要旨
Preface This is theusermanual forthe80E01, 80E02, 80E03, 80E04, and 80E06 sampling modules. It covers thefollowing information: Description ofthecapabilities ofthesampling modules and how to install them Explanation ofhow to operatethesampling modules: how to control acquisition, processing, and input/output ofinformation List ofthespecifications ofthesampling modules You may want to visit theTektronix Websiteat http://www.tektronix.com forthe latest revision oftheuserdocumentation. Select
ページ12に含まれる内容の要旨
Preface viii 80E00 Electrical Sampling Modules UserManual
ページ13に含まれる内容の要旨
GettingStarted TheTektronix 80E01, 80E02, 80E03, 80E04, and 80E06 sampling modules are high-performancesampling modules that can beinstalled in thefollowing main instruments: DSA8200 Digital Serial Analyzer CSA8000, CSA800B, and CSA8200 Communications Signal Analyzers TDS8000, TDS8000B, and TDS8200 Digital Sampling Oscilloscopes Properoperation oftheelectrical sampling modules requires that theappropriate application softwareis installed on themain instrument. In Table1, each new releaseof
ページ14に含まれる内容の要旨
Getting Started ProductDescription Thesampling modules providethefeatures shown in Table2. Table2:Samplingmodulefeatures Feature 80E01 80E02 80E03 80E04 80E06 Numberof independent channels 1 2 2 2 1 1 1 Rise time 7 ps, typical ≤28 ps ≤17.5 ps ≤17.5 ps ≤5.0 ps, typical Bandwidth 50 GHz 12.5 GHz 20 GHz 20 GHz 70 GHz, typical 3 Displayed noise ≤2.3 mV ≤800V ≤1.2 mV ≤1.2 mV ≤2.8 mV RMS RMS RMS RMS RMS Select channel buttons forquick Yes Yes Yes Yes Yes trace identification Maximum non-destructive i
ページ15に含まれる内容の要旨
Getting Started 50Ω Sampler Tomaininstrument Strobe Strobedrive Frommaininstrument Generator Note:the80E01and80E06are singlechannelmoduleswitha dedicatedstrobedriveand generator. Sampler Tomaininstrument 50Ω Figure1:Samplingmoduleblockdiagram Channelindicator SELECT channelbutton light(yellow) TEKPROBEconnector TDRonindicator light(red) (80E04) Hold-downscrew Signalconnector Rightchannel Leftchannel Figure2:Samplingmodule,80E04shown 3 80E00 Electrical Sampling Modules UserManual
ページ16に含まれる内容の要旨
Getting Started OptionsandAccessories This section lists thestandard and optional accessories availableforthesampling modules. Options Thefollowing options can beordered forthesampling modules: Option C3: Threeyears ofcalibration services Option C5: Fiveyears ofcalibration services Option D3: Test Dataforcalibration services in Option C3 Option D5: Test Dataforcalibration services in Option C5 Option R3: Repairwarranty extended to coverthreeyears Option R5: Repairwarranty extended to
ページ17に含まれる内容の要旨
Getting Started Table4:Optionalaccessories(cont.) Item Partnumber Powerdivider 015-0565-xx SMA accessory kit 020-1693-xx Torque wrench, 8 mm (5/16 inch)open end n.a. 3.5maleto3.5femaleSMA 015-0552-xx Slip-on SMA connector 015-0553-xx 3.5 mm 50Ωconnector(SMA male-to-female) 015-0549-xx BNC female 75Ωto 50Ωtype N minimum loss attenuator 131-0112-xx CSA8000 & TDS8000 Series Service Manual 071-0438-xx DSA8200 Service Manual 071--2049--xx Terminator, ECL 015-0558-xx Connectorsaver, 3.5 mm SMA 015-054
ページ18に含まれる内容の要旨
Getting Started Installation Thesampling modules fit into thefront panel ofthemain instrument. Figure3 shows thefront panel ofaDSA8200 and thelocations ofthesampling-module compartments. Largemodules Moduleejectors Smallmodules Left-mostsmallmodule Thissmallmodule compartmentisnotusableif compartmentisnotusableif alargemoduleisinstalled alargemoduleisinstalled inright-mostslot inleft-mostslot Figure3:Samplingmodulecompartments At least onesampling modulemust beinstalled in an instrument to sampl
ページ19に含まれる内容の要旨
Getting Started Know yoursignal source. Ifit is capableofdelivering overvoltages, it is saferto not depend on thesignal sourcesettings forprotection, but instead usean external attenuatorthat protects theinput from theworst-caseconditions. For example, fora20V maximum sourceconnected to a3V maximum sampling module, usea10X attenuator. Wherepossible, connect yourcables to thesignal sourcefirst, and to thesampling modulesecond. CAUTION. To prevent damage from electrostatic discharge, install 50Ω t
ページ20に含まれる内容の要旨
Getting Started ModuleInstallation To install asampling module, first turn offtheinstrument using thefront-panel On/Standby switch. Then placethesampling modulein acompartment and slowly push it in with firm pressure. Oncethesampling moduleis seated, turn thehold-down screw on thesampling moduleto tighten thesampling module into place. SeeFigure4. CAUTION. To prevent damage to the sampling moduleor instrument, never install or removea sampling modulewhen theinstrument is powered on or when eithe