ページ1に含まれる内容の要旨
HUM
Humidifiers
ProductData
Controlling indoor humidity is very important. In many cases the
air inside a home is drier than a desert. Dry, indoor air is often the
culprit for such common problems as itchy or cracked skin, eye
irritation, dry nasal passages, and damaged home furnishings. Dry
indoor air can also increase the possibility of catching cold and flu
viruses and can reduce the efficiency and effectiveness of the
heating system.
All of these problems can be alleviated with the help of a
ページ2に含まれる内容の要旨
MODELNUMBERNOMENCLATURE HUM BB LFP 14 18 ProductType Brand ModelType Series Gallons(Liters)PerDay Humidifier Bryant LFP --- Large Fan Powered 14 --- LFP LFP --- 18 (68) SBP --- Small Bypass 24 --- SBP, LBP, WBP SBP --- 12 (45) LBP --- Large Bypass 10 --- SFP LBP --- 17 (64) SFP --- Small Fan Powered SFP --- 12.8 (48) WBP --- Water Saving WBP --- 17(64) LargeBypass PHYSICALDATA MODEL HUMBBLFP1418 HUMBBLBP2417 HUMBBWBP2417 HUMBBSBP2412 HUMBBSFP1016 Gallons 18(68) 17(64) 12(45) 12.8(48) (Liters)/Da
ページ3に含まれる内容の要旨
DIMENSIONS Model HUMBBLBP2417 & HUMBBWBP2417 Model HUMBBLFP1418 14.0 10.25 (260) (356) 10.25 16.0 (260) (406) Damper "Season" Selector SUMMER 15.75 (400) Built-In 18.0 Bypass (457) Damper DUCT CUT-OUT SIZE 5.68 W x H DUCT CUT-OUT SIZE (144) 14.81 x 14.25 W x H (376 x 362) 9.88 x 12.75 (251 x 324) Model HUMBBSBP2412 Model HUMBBSFP1016 10.25 14.0 (260) (356) OPTIONAL WATER VALVE MOUNTING WATER SIDE INLET DOOR Damper "Season" Selector SUMMER 13.0 (3
ページ4に含まれる内容の要旨
RECOMMENDEDRELATIVEHUMIDITYBYOUTDOORTEMPERATURE OUTDOORTEMP OUTDOORRELATIVEHUMIDITY INDOORRELATIVEHUMIDITY MAXRECOMMENDEDINDOOR _F(_C) (%) (%)W/OHUMIDIFIER* RELATIVEHUMIDITY{ ---10 (---23) 30to70 1to2 20(Lo) 0 (---18) 30to70 2to4 25 10(---12) 30to70 3to6 30 20(---7) 30to70 4to10 35 30(---1) 30to70 6to15 40(Med) * Indoor relative humidity level when outdoor air isheatedto 72_F/22_C. { Asstipulatedby theAir ConditioningContractorsof America. INDOORRELATIVEHUMIDITYLIMITFORNOWINDOWCONDENSATION (Indo
ページ5に含まれる内容の要旨
TYPICALHUMIDIFIERINSTALLATIONS HORIZONTAL Built-in Bypass Damper Built-in Bypass Damper Built-in Bypass Damper DOWNFLOW UPFLOW * *Note - It is recommended that hot water be supplied in this return air application. UPFLOW UPFLOW A06225 5 HUM
ページ6に含まれる内容の要旨
HUMIDIFIERREPLACEMENTWATERPANELS DESCRIPTION USEDWITH TOTALINE ORDERING NO. HUMBBLFP1418 P110---3545 HUMBBLBP2417 ReplacementWaterPanel HUMBBSBP2412 P110---1045 HUMBBSFP1016 324897---761 HUMBBWBP2417 P110---4545(2pack) HUMIDIFIERACCESSORIES DESCRIPTION USEDWITH PART NO. HUMBBLFP1418 HUMBBLBP2417 HumidiTractAutomaticControl KUAWC0101CAC---A10 HUMBBSBP2412 HUMBBWBP2417 HumidistatManualControl HUMBBWBP2417 4363(Totaline) Relay HUMBBLFP2417 HN61KQ120(Totaline) E2008 BryantHeating &Cooling SystemsD7