ページ1に含まれる内容の要旨
No Frost Refrigerator
PARTS &
SERVICE Manual
Models
5622 285L 2G UL 110V QCS - WHITE
5624 285L 2G UL 110V QCS - S.GREY
6670 220L 2G 110V/60 HZ,NARSO-GREY UL Kitting
This document is only intended for qualified technicians who are aware of the respective safety regulations.
Revised on 25/03/2003 Subject to modification
Document No. WOI/GNF/2003/003
ページ2に含まれる内容の要旨
Whirlpool of India Limited Contents 1.0 Safety precautions & warnings 2-3 2.0 Technical Specifications 4-6 3.0 Circuit diagram 7 4.0 Sealed system schematic layout 8 7.0 Refrigerator does not operate 9 7.0 Trouble shooting -cooling system 10 7.1 Trouble shooting defrosting 11 8.10 Cabinet assembly parts diagram 12 8.11 Cabinet assembly parts list 13 8.20 Shelves part diagram 14 8.21 Shelves parts list
ページ3に含まれる内容の要旨
Safety precautions and warnings: Read all instructions before using this appliance in order to avoid risk of accident or possible damage. Warning / Caution Description of symbols This symbol is intended Indicates prohibition to alert the user to the Warning Do not disassemble possible death or injury. Do not contact Adhere the instruction strictly This symbol is intended to alert the user to the Unplug from the electrical outlet Caution possible injury or damage. Earth the appliance to avoi
ページ4に含まれる内容の要旨
Caution Do not store bottled food Do not store food in Do not store anything or drinks in the freezing unstable manner. other than food in the compartment. refrigerator. Bottles may explode Opening the door may Medical supplies, which causing personal injury. trigger loose items to slip need to be under strict & cause injury. temperature control, should not be stored in the refrigerator. Prohibition Prohibition Prohibition Do not put on top of the When replacing electric When servicing
ページ5に含まれる内容の要旨
Technical Specifications for 220L DLX Model Dimensions Cooling agent Height 1408mm Type -R134a Width 550mm Quantity – 96Grams Depth 625mm Capacity 220L Refrigerator compartment-150L Freezer compartment-70L Thermostat Cooling Total – 220L Switching values Cut in Temperature COLD:-3.9 to -7.3 Deg.Cen, MID: -2.4 to -0.9 Deg.Cen, WARM: 0.5 to
ページ6に含まれる内容の要旨
Technical Specifications for 285L Elite Model Dimensions Cooling agent Height: 1725mm Width: 550mm Type R134a Depth: 625mm Quantity 96Grams Capacity-285L Thermostat Cooling Refrigerator Compartment: 215L Cut in temperature Freezer Compartment: 70L COLD:-1.7 to 1.7 Deg.Cen Total : 285L MID : 2.0 to3.6 Deg.Cen WARM:2.8 to 6.2 Deg.Cen Electrical Connectio
ページ7に含まれる内容の要旨
110-130 V Page 4 This document is only intended for qualified technicians who are aware of the respective safety regulations. Revised on 25/03/2003 Subject to modification Document No. WOI/GNF/2003/003
ページ8に含まれる内容の要旨
6.0 Sealed System Schematic Layout : Evaporator Condenser (Foamed in three sides.) Heat Loop (Foamed) Drier Compressor Precooler This document is only intended for qualified technicians who are aware of the respective safety regulations. Page 8 Revised on 25/03/2003 Subject to modification Document No. WOI/GNF/2003/003
ページ9に含まれる内容の要旨
7.0 Trouble shooting method The refrigerator does not operate Is the interior Make sure that the light on when the door switch refrigerator is plugged is pushed? in at the wall outlet. Make sure that the Does the Replace the defective thermostat is compressor operate? part electrically connected If the fan operates when you push the The compressor Check the door switch,it is is operated for more defrost timer normal(Replace if it is than defective) 30 Min. andthere is no cooling Check
ページ10に含まれる内容の要旨
7.0. Trouble check for the cooling cycle : Symptom Cause Suggestions ! The EVAP cools down and warms again. Replace the refrigerant. Moisture in the refrigerant ! The condenser warms in cause the malfunction. proportion as the EVAP cools. ! The process continues to repeat. ! The condenser is cold. Locate the disturbed ! The EVAP is not cold. Foreign substances section and ! The temperature of the compressor hamper the cooling cycle. make repairs. is high. ! No difference in temperatu
ページ11に含まれる内容の要旨
7.1 Defrosting mechanism does not work : No Check that the defrost timer Replace the defrost timer operates properly Yes No Check the temperature fuse Replace the temperature fuse Yes No Replace the bimetal thermometer Check the bimetal thermometer Yes No Replace the defrost heater Check the defrost heater 7.2 Defrosting mechanism does not work : No ! Check the cooling fan motor Does not cooling fan operate? ! Check the door switch ! Defrost timer No ! Temperature fuse / Bimetal Is the fr
ページ12に含まれる内容の要旨
Page 9 This document is only intended for qualified technicians who are aware of the respective safety regulations. Revised on 25/03/2003 Subject to modification Document No. WOI/GNF/2003/003
ページ13に含まれる内容の要旨
8.11 CABINET ASSEMBLY PARTS Loc No Part Code Description 5622 5624 6670 1 A2010870000 SLEEVE- HINGE 2 2 2 1 A201416000J HINGE ASSY TOP - GNF, 2G, 3G 1 1 1 5 A201107200B FILLER- WRAPPER CORNER- WHITE 1 6 21499540000 SWITCH 2 TERM ROCKER ARM 1 1 1 7 A2080630700 DOOR ASSEMBLY FC (FIP) - GREY SLICK 1 1 7 A2080632000 DOOR ASSEMBLY FC (FIP) 2G - WHITE 1 8 A2080452000 END CAP FC-TOP, WHITE 1 9 A2080152000 HANDLE- DOOR, FC- WHITE 1 9 A2080462000 END CAP - FC BOTTOM, WHITE 1 9 A20
ページ14に含まれる内容の要旨
Page 11 This document is only intended for qualified technicians who are aware of the respective safety regulations. Revised on 25/03/2003 Subject to modification Document No. WOI/GNF/2003/003
ページ15に含まれる内容の要旨
8.21 SHELVES PARTS Loc No Part Code Description 5622 5624 6670 42 A201012000A PAN CHILLER 285L 1 1 42 A201224000E PAN CHILLER- 220/250L 1 44 A208172000A HALF SHELF - QUICK FREEZE 1 1 1 44 A2083020000 WIRE SHELF ASSY, DOOR COOLING -INTELCOOL 1 45 A201013000G DOOR- CHILLER 1 1 46 A203793000B SHELF- RC (SAN) 2 2 1 47 A2037950000 SHELF BACK- TRIPLE (SAN) 1 1 1 48 A203794000A SHELF FRONT- TRIPLE (SAN) 1 1 1 49 A201036000K COVER -CRISPER 1 1 49 A201207000H COVER -CRISPER 1
ページ16に含まれる内容の要旨
Page 13 This document is only intended for qualified technicians who are aware of the respective safety regulations. Revised on 25/03/2003 Subject to modification Document No. WOI/GNF/2003/003
ページ17に含まれる内容の要旨
8.31 FREEZER COMP. ASSY. PARTS LIST Loc No Part Code Description 5622 5624 6670 65 A2016380000 GROMMET SOUND DEADENING- BACK 1 1 1 66 A201637000A GROMMET SOUND DEADENING- FRONT 1 1 1 67 A201476000A WEDGE ,EVAP MOUNTING- LH 1 1 1 68 A201475000D WEDGE ,EVAP MOUNTING- RH 1 1 1 68 A2035710000 FOIL- EVAPORATOR WEDGE 1 1 1 69 A2013780000 SOUND DEADENING- EVAPORATOR 1 1 1 69 A2112900000 EVAPORATOR-SPIROTECH 1 1 1 70 A2036310000 DEFROST HEATER, 110V/60HZ- TAIWAN 1 1 1 72 A201492000B COVE
ページ18に含まれる内容の要旨
Page 15 This document is only intended for qualified technicians who are aware of the respective safety regulations. Revised on 25/03/2003 Subject to modification Document No. WOI/GNF/2003/003
ページ19に含まれる内容の要旨
8.41 CONTROL BOX ASSY. PARTS LIST Loc No Part Code Description 5622 5624 6670 90 A201617000B THERMOSTAT GE- 220L 1 90 A2016300000 THERMOSTAT WT ASSY -220L 1 90 A2016940000 THERMOSTAT WT ASSY -285L, SIEBE 1 1 91 A2113830000 WIRING ASSY.CONT BOX- PUERTORICO NON BAT 1 1 1 92 A2111090000 DEFROST TIMER, PARAGON - 115V-60HZ 1 1 1 93 A2013960000 BULB- E14, 110V SUNSHINE KOREA 1 1 1 94 A2014490000 SOCKET ASSY- LIGHT 1 1 1 95 A201593000G CONTROL BOX -285L NEW GRAPHICS 1 1 95 A2036980
ページ20に含まれる内容の要旨
Page 17 This document is only intended for qualified technicians who are aware of the respective safety regulations. Revised on 25/03/2003 Subject to modification Document No. WOI/GNF/2003/003