ページ1に含まれる内容の要旨
Quality Refrigeration
OWNER’S MANUAL OWNER’S MANUAL
OWNER’S MANUAL OWNER’S MANUAL OWNER’S MANUAL
Instructions for the installation, operation
and maintenance of all Traulsen Spacesaver Models:
Refrigerator Models: UR30HT, UR48HT, UC27HT
Freezer Model: UR30LT
Refrigerator/Freezer Model: UR48DT
Wine Cabinets: UR30WT, UR48WT, UC27WT
This Traulsen unit is built to our highest quality standards. We build our refrigerators, freezers and heated
cabinets this way as a matter of pride. This philosophy
ページ2に含まれる内容の要旨
TABLE OF CONTENTS I. The Serial Tag Page 1 V. Operation II. Receipt Inspection Page 2 a-Adjusting The Temperature Page 6 III. Installation b-Automatic Defrost Page 6 a-Location Page 2 b-Packaging Page 2 VI. Care & Maintenance c-Installing Legs or Casters Page 2 a-Cleaning The Condenser Page 6 d-Shelf Pins Page 3 b-Hinge Replacement Page 6 e-Installing The Condensate Evaporator Page 3 c-Replacing The Gaskets Page 6 f-Remote Installation Page 3 d-Cleaning The Exterior Page 7 g-Cord & Plug Page 3 e
ページ3に含まれる内容の要旨
II. RECEIPT INSPECTION III. INSTALLATION (continued) All Traulsen products are factory tested for perfor- III. c - INSTALLING LEGS OR CASTERS: mance and are free from defects when shipped. The 6” high stainless steel legs are supplied standard for utmost care has been taken in crating this product to all Traulsen Spacesaver units. Casters in lieu of legs protect against damage in transit. All interior fittings are available as an optional accessory for the same have been carefully secured and
ページ4に含まれる内容の要旨
III. INSTALLATION (continued) III. f - REMOTE INSTALLATION: III. d - SHELF PINS: Remote models are supplied without compressors, The unit is supplied with shelves and shelf pins in- solenoid valves, etc. The correct voltage, amp listing, stalled. Check all shelf pins to assure they are tight- refrigerant and BTU’s are listed on the unit’s serial tag. ened down as they may have come loose during ship- It is the responsibility of the installer to specify and ping. Rotate the pins clockwise unti
ページ5に含まれる内容の要旨
84” Min. III. INSTALLATION (continued) III. k - BUILT-IN INSTALLATION: 1234567890123456789012345678901212345678901 1 23456789012345678901234567890121234567890 1 Select a proper location for your unit away from ex- 1 23456789012345678901234567890121234567890 1 1 23456789012345678901234567890121234567890 1 1 23456789012345678901234567890121234567890 1 treme heat or cold. Due to the unique air flow of the 1 23456789012345678901234567890121234567890 1 1 23456789012345678901234567890121234567890 1 u
ページ6に含まれる内容の要旨
69” III. INSTALLATION (continued) III. l - ELECTRICAL OUTLET INSTALLATION: Refer to the diagram below to determine the correct location for the electrical outlet for built-in units. 3” 4” 8” 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 1234567890 Electrical Outlet 1234567890 1234567890 1234567890 Insta
ページ7に含まれる内容の要旨
V. OPERATION VI. CARE & MAINTENANCE V. a - ADJUSTING THE TEMPERATURE: VI. a - CLEANING THE CONDENSER: The refrigeration system has been properly charged The most important thing you can do to insure a long, and tested at the factory. Plug the unit into the power reliable service life for your Traulsen is to regularly outlet to determine if the compressor(s) is running. If clean the condenser coil. not, check the “ON/OFF” switches behind the louver assembly. On a refrigerator/freezer models (U
ページ8に含まれる内容の要旨
VI. CARE & MAINTENANCE (cont’d) VII. MISC. OPERATIONS VI. c - REPLACING THE GASKETS (cont’d): VII. a - ADJUSTING THE SHELVES: gently hitting with a mallet until the gasket is com- For shelves mounted on pins, first select the desired pletely seated in place (see figure 9 for proper gasket location and remove the white plastic covers in the placement). interior back and sides by rotating them counter-clock- Inside Door Panel wise. Next, remove the existing shelf pins by rotating them counter-clo
ページ9に含まれる内容の要旨
VIII. OTHER (cont’d) VIII. b - SPARE PARTS: Spare or replacement parts may be obtained through a parts supplier or one of our authorized service agents. A complete list of authorized service agents accompanies this manual and is also posted on our company's official website @ www.traulsen.com. VIII. c - WARRANTY REGISTRATION: For your convenience, the warranties on your new Traulsen unit may be registered with us by one of two methods. Completing the enclosed warranty card (shipped with the un
ページ10に含まれる内容の要旨
X. WARRANTY INFORMATION STANDARD DOMESTIC WARRANTY TRAULSEN & CO., INC. warrants new equipment to the original purchaser, when installed within the United States against defective material and workmanship for one (1) year from the date of original installation. Under this warranty, TRAULSEN & CO., INC. will repair or replace, at its option, including service and labor, all parts found to be defective and subject to this warranty. The compressor part is warranted for an additional four (4) years.
ページ11に含まれる内容の要旨
XI. INDEX A N Adjusting The Temperature 6 Nylon Netting 2 B O BTU’s 3 Outlet - Electrical 3, 4, 5 Built-In Installation 4 P C Pallet - Shipping 2 Casters 2 Pans - Drawer 7 Cleaning - The Condenser 5 Plastic Covering 2 Cleaning - The Exterior 6 Power Supply 3 Cleaning - The Interior 6 Clearance 3 R Compressor Hold Down Provisions 3 Recessed Installation 4 Compressor - Oil 2 Refrigerant 2 Condensate Evaporator 3 Remote Installation 3 Condensing Unit 6, 8 Return Authorization 2 Cord & Plug 3 S D Se
ページ12に含まれる内容の要旨
HOURS OF OPERATION: Monday thru Friday 7:30 am - 4:30 pm CST Traulsen 4401 Blue Mound Road Fort Worth, TX 76106 Phone: (800) 825-8220 Fax-Svce: (817) 740-6757 Website: www.traulsen.com Quality Refrigeration © 2003 Traulsen - All Rights Reserved