ページ1に含まれる内容の要旨
GAPAB
PERFECTAIRtAIRPURIFIERFORFANCOILS
SIZES1620,2020,AND2420
Installation Instructions
NOTE: Read the entire instruction manual before starting the
install.
TABLEOFCONTENTS
PAGE
INTRODUCTION .................................... 1
HOW IT WORKS .................................... 1
SAFETY CONSIDERATIONS .......................... 1
APPLICATION CONSIDERATIONS .................... 2
INSTALLATION ................................... 3--6
START--UP AND OPERATION ......................... 7
MAINTENAN
ページ2に含まれる内容の要旨
Transitions ! CAUTION If the return air duct or fan coil openings do not fit the Perfect Airt Air Purifier cabinet openings, gradual transitions are recommended to reduce air turbulence and maximize efficiency. PERSONAL INJURY HAZARD No more than 20 degrees (about 4 in. per running ft.) of Failure to followthis caution may result in personal injury. expansion should be used on each side of the transition fitting. Ozone in concentrations above 0.05 PPM may be Turning Vanes hazardous to health. If
ページ3に含まれる内容の要旨
INSTALLATION ! WARNING Step1 —CheckPerfectAirtAirPurifierComponents ELECTRICAL SHOCK AND UNIT DAMAGE ! CAUTION HAZARD Failure to follow this warning could result in personal CUT HAZARD injury or death. Failure to followthis caution may result in personal injury. Only a trained, experienced service person should install Sheet metal parts may have sharp edges or burrs. Use care the Perfect Airt Air Purifier. A thorough check of the and wear appropriate protective clothing and gloves when unit inst
ページ4に含まれる内容の要旨
Step3 —MountCabinet ! a. Turn off power to the heating and cooling system. WARNING b. Removetheexistingfancoilfilteranddiscard.Excessive ELECTRICAL SHOCK AND HIGH VOLTAGE systemstaticpressuremayresultifthePerfectAirtAir HAZARD Purifier is used with other filtration devices. Failure to follow this warning could result in personal c. Removetheairpurifiercartridgeandenhancementmod- injury or death. ule from the Perfect Airt Air Purifier cabinet. Before installing or servicing system, always turn of
ページ5に含まれる内容の要旨
Step4 —Wiring ! a. Ensure power has been removed from the heating and WARNING cooling system. ELECTRICAL SHOCK AND HIGH VOLTAGE b. Turn the Perfect Airt Air Purifier power switch off. HAZARD c. Connect the power cord and the flow sensor cord to the Failure to follow this warning could result in personal injury power supply connector and the flow sensor connector or death. (see Fig. 7 and Fig. 8). Before installing or servicing system, always turn off main NOTE: The power cord can be routed throu
ページ6に含まれる内容の要旨
FUSED POWER CONNECTOR LEADS AIR PURIFIER TO FAN COIL FIELD POWER CONNECTION FROM INSTALLATION COMPONENTS POWER CORD (IN BAG ATTACHED TO POWER CORD) TO L2 FIELD POWER SUPPLY 5 AMP IN-LINE FUSES TO L1 FIELD POWER SUPPLY GROUND: ATTACH TO FAN COIL GROUND (CHASSIS) TO FAN COIL FIELD POWER CONNECTION CABLE CONNECTOR TO SECURE POWER CORD TO FAN COIL CABINET A06515 Fig. 10 --- Fan Coil Chassis Ground Air Flow Sensor 1) Slide flow sensor tabs into support bracket 2) Rotate flow sensor and clip into brac
ページ7に含まれる内容の要旨
START--UPANDOPERATION Step1 —CheckingAirPurifierOperation ! WARNING ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect Power Indicator switch. A06370 a. AttachthePerfectAirtAirPurifierdoortothecabinet. Fig. 13 --- Power Indicator Amagnetinthedoor(seeFig.8)isusedtoactivateasafe- tyswitchinthepowersupplywhenthedoorisin
ページ8に含まれる内容の要旨
Atthetimeofairpurifiercartridgereplacement,ifapowdery residueisnoticedonthetipsofthepointsintheionization ! WARNING array,proceedtocleanthembycompletingthefollowing steps: CUTHAZARD Step1 —Turntheheatingandcoolingsystempoweroff. Failuretofollowthiscautionmayresultinpersonalinjury. Sheet metal parts may have sharp edges or burrs. Use care ! and wear appropriate protective clothing and gloves when WARNING handlingparts. ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Step6 —SlideouttheSafetyScreenandseta
ページ9に含まれる内容の要旨
Step4 —Confirmthat208/230VACpowerisprovided.Attach TROUBLESHOOTING powersupplyconnectortotheairpurifierwhenthefancoil blowerisoperating. ! CAUTION NOTE: Even though power is supplied to the Perfect Airt Air Purifier, it will not turn on unless the airflow sensor senses SAFETY HAZARD airflow or the airflow sensor’s bypass plug is inserted. Failure to follow this caution may result in personal injury Step5 —Confirmthattheairflowsensorcableorairflowsensor or equipment damage. bypassplugisconnectedt
ページ10に含まれる内容の要旨
SPECIFICATIONSANDDIMENSIONS Table1—SpecificationsandDimensions Specifications GAPABXBB1620 GAPABXBB2020 GAPABXBB2420 Color TaupeMetallic TaupeMetallic TaupeMetallic CabinetMaterial 20Ga.PowderCoatedSteel 20Ga.PowderCoatedSteel 20Ga.PowderCoatedSteel Electrical 208/230v/60Hz 208/230v/60Hz 208/230v/60Hz Maximum Airflow (CFM) 1350 1800 2000 Efficiency EquivalenttoMERV15 EquivalenttoMERV15 EquivalenttoMERV15 ReplacementCartridge GAPCBBAR1620 GAPCBBAR2020 GAPCBBAR2420 Initial Pressure Drop (inw.c.) .
ページ11に含まれる内容の要旨
WARRANTY FORSERVICEORREPAIR,FOLLOWTHESESTEPSINORDER: FIRST: Contact the installer. You may find their name on the product or in your Homeowner’s Packet. If the installer’s name is not known, call your builder or home retailer if yours is a new residence. SECOND: Contact the nearest distributor. (See telephone yellow pages.) THIRD: Contact: Bryant Heating and Cooling Systems Consumer Relations P.O. Box 4808 Syracuse, New York 13221 Telephone: 1--800--428--4326 Model No. __________________________
ページ12に含まれる内容の要旨
EBryantHeating &Cooling Systems 7310W.MorrisSt. Indianapolis,IN 46231 PrintedinU.S.A. EditionDate: 02/07 CatalogNo. IIGAPAB---0---2 Manufacturerreservestherighttodiscontinue,orchangeatanytime,specificationsordesignswithoutnoticeandwithoutincurringobligations. Replaces: IIGAPAB---0---1 12 GAPAB