Model CBC/CBR-103,104,105,106,107
SECTION 3. OPERATION
3-1. INTRODUCTION This section provides explanations of all controls, along
with operating procedures and daily maintenance. Read the
Introduction, Installation and Operation Sections before
operating the unit.
Wait at least 4 hours before plugging the unit into an
electrical supply. The gases and oils in the refrigeration
system need to settle before operating the compressor, or
damage to the compressor could result.
3-2. OP
ページ2に含まれる内容の要旨
Model CBC/CBR-103,104,105,106,107 3-2. OPERATING CONTROLS (Continued) 3 2 1 Figure 3-1 4 5 303 3-2
ページ3に含まれる内容の要旨
Model CBC/CBR-103,104,105,106,107 3-3. BASIC OPERATION 1. Turn power switch to ON position. 2. Wait for temperature to reach operating temperature, 36 to 38° F (2.2 to 3.3° C). 3. Place chilled, prepackaged product into case. Do not stock product in the case beyond the load height limit of 9 inches (23 cm), or over the front edge. Prod- uct temperatures may become unsafe, and increase operating costs. Do not use mechanical devices or other means to quicken the defrosting process, other
ページ4に含まれる内容の要旨
Model CBC/CBR-103,104,105,106,107 3-4. CLEANING Every 3 Months: (Continued) 1. Remove all electrical power supplied to the unit by unplug- ging the power cord from the wall, or by turning off the wall circuit breaker. 2. Remove all product from the unit. 3. Remove the riser and trays from the unit and clean with soap and water at a sink. 4. Clean interior surfaces with a soft cloth, soap and water. Do not use steel wool, other abrasive cleaners or cleaners/sanitizers containi
ページ5に含まれる内容の要旨
Model CBC/CBR-103,104,105,106,107 3-5. PROGRAMMING 1. Press and hold for 4 seconds. The “DEF/SET” light flashes in display. Temperature Setpoint 2. Press the or to change the temperature setpoint, within 5 seconds. After 5 seconds, the last entered setpoint stays in memory. Other Parameters 3. Press to access the other parameters. Each press of the accesses the next parameter. The parameters are: d: (differential) (-15...15 range) LS: lower set; lower user-access
ページ6に含まれる内容の要旨
Model CBC/CBR-103,104,105,106,107 3-5. PROGRAMMING dS: (defrost system (computation)) dF=digifrost feature; Continued defrost start time based on total compressor running time. rt=real time; defrost start frequency, based on real time dI: (defrost interval) defrost frequency in hours, based on the selection of “dS” dE: (defrost endurance) total (maximum) length of a defrost cycle, expressed in minutes. (1...99 range) dL: (display lock) temperature display is locked during