ページ1に含まれる内容の要旨
Henny Penny
Cold Tops
Model CMC/CMR-103
Model CMC/CMR-104
Model CMC/CMR-105
Model CMC/CMR-106
Model CMC/CMR-107
OPERATOR’S MANUAL
ページ2に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 LIMITED WARRANTY FOR HENNY PENNY APPLIANCES Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the original purchaser only for Henny Penny appliances and replacement parts: NEW EQUIPMENT: Any part of a new appliance, except lamps and fuses, which proves to be defective in material or workmanship within two (2) years from date of original installation, will be repaired or replaced without charge F.O.B. factory
ページ3に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 TABLE OF CONTENTS Section Page Section 1. INTRODUCTION ................................................................................................................... 1-1 1-1. Henny Penny Cold Tops .............................................................................................. 1-1 1-2. Features ....................................................................................................................... 1-1 1-3. Proper Care ........
ページ4に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 SECTION 1. INTRODUCTION 1-1. COLD TOPS The Henny Penny cold tops are full service units, designed to hold chilled or refrigerated products. The units are electronically controlled for easy use and for consistent operation. 1-2. FEATURES • Can be matched with hot or cold merchandisers in all lengths • Electronic Controls • Stackable units on top of bases • Low speed air circulation • Easily maintained • Fluorescent lighting with electronic ballast (CE-m
ページ5に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 1-5. SAFETY The Henny Penny cold tops have many safety features incorporated. However, the only way to ensure a safe operation is to fully understand the proper installation, operation, and maintenance procedures. The instructions in this manual have been prepared to aid you in learning the proper procedures. Where information is of particular importance or safety related, the words NOTICE, CAUTION, and WARNING, are used. Their usage is described below. SA
ページ6に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 SECTION 2. INSTALLATION 2-1. INTRODUCTION This section provides the installation for Henny Penny cold tops. Installation of this unit should be performed only by a qualified service technician. Do not puncture the unit with any objects such as drills or screws, or component damage or electrical shock could result. 2-2. UNPACKING The Henny Penny Cold Top has been tested, inspected, and expertly packed to insure arrival at its destination in the best poss
ページ7に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 2-2. UNPACKING (Continued) Take care when moving the fryer to prevent personal injury or damage to the refrigeration system. The CMC-107s weigh over 700 lbs. (318 kg). 4. Peel off any protective covering from exterior of the cabinet. 5. Install the grids into unit. 6. Unpack sliding thermal doors and side glass. Install on rear and side of unit. 7. Your cold top is now ready for operation. 2-3. ELECTRICAL The Cold Top is available as a 120
ページ8に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 2-4. LOCATION Place the cold tops in an area where product can be loaded and unloaded without interruption. For proper operation, level the unit by adjusting the bolts under the base, and leave 3 feet (91.44 cm) clearance behind the unit for ventilation and service. For maximum efficiency, units should be operated in an air-condi- tioned environment, with maximum air temperature of 75° F (24° C), and 55% relative humidity. Wait at least 4 hours before plu
ページ9に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 2-7. COMPRESSOR SIZE Model CMC Motor HP CMR Motor HP AND LOAD CMC/ BTU Load UL CE UL CE CMR R-22 R-134a R-22 R-134a 103 2860 1/4 1/3 Remote 104 2860 1/4 1/3 Compressor 105 2830 1/3 1/2 Supplied 106 2830 1/3 1/2 By Other 107 3840 1/2 1/2 BTU load sized at evaporator temperature + 20 F or -6 C. 2-8. FOOT PRINT DRAWING CMR MODELS DRAIN& REFRIGERATION CONNECTIONS 2-4 303
ページ10に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 2-9. CUT OUT DIMENSIONS FOR DRY BASE OR TABLE INSTALLATION 303 2-5
ページ11に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 2-10. FLOURESCENT LIGHTING No. AND BULB REPLACEMENT Model of Lights Size CMR/CMC-103 1 36 in. (.914 m) CMR/CMC-104 1 48 in. (1.22 m) CMR/CMC-105 1 24 in. (.610 m) 1 36 in. (.914 m) CMR/CMC-106 2 36 in. (.914 m) CMR/CMC-107 1 36 in. (.914 m) 1 48 in. (1.22 m) UL Units 1. Pull the bulb out of the sockets. 2. Remove the bulb guard caps. 3. Install new fluorescent bulb in reverse order. CE Units 1. Remove the bulb cover. 2. Rotate the bulb. 3. Pull
ページ12に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 1. Remove bolts securing the Cold Top to the skid, and save bolts 2-11. COLD TOP ON A COLD for later use. BASE INSTALLATION INSTRUCTIONS 2. Carefully set Cold Top on top of the Cold Base. Take care when moving the fryer to prevent personal injury or damage to the refrigeration system. The CMC-107s weigh over 700 lbs. (318 kg). 3. Line up the 2 front holes and secure the top to the base using the bolts from step 1. Figure 2-1. Figure
ページ13に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 SECTION 3. OPERATION 3-1. INTRODUCTION This section provides explanations of all controls, along with operating procedures and daily maintenance. Read the Introduction, Installation and Opeation Sections before operating the unit. Wait at least 4 hours before plugging the unit into an electrical supply. The gases and oils in the refrigeration system needs to settle before operating the compressor, or damage to the compressor could result. 3-2. OPE
ページ14に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 3-2. OPERATING CONTROLS (Continued) 3 2 1 Figure 3-1 4 5 303 3-2
ページ15に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 3-3. BASIC OPERATION 1. Turn power switch to ON position. 2. Wait for temperature to reach operating temperature, 34 to 38° F (1.1 to 3.3° C). 3. Place chilled product into case. Do not block the air return and air discharge vents with product. Product temperatures may become unsafe, and increase operating costs. Do not use mechanical devices or other means to quicken the defrosting process, other than those recommended by the manufacturer, or damage to
ページ16に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 3-4. CLEANING Every 3 Months: (Continued) 1. Remove all electrical power supplied to the unit by unplugging the power cord from the wall, or by turning off the wall circuit breaker. 2. Remove all product from the unit. 3. Remove the riser and trays from the unit and clean with soap and water at a sink. 4. Clean interior surfaces with a soft cloth, soap and water. Do not use steel wool, other abrasive cleaners or cleaners/sanitizers containing
ページ17に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 3-5. PROGRAMMING 1. Press and hold for 4 seconds. The “DEF/SET” light flashes in display. Temperature Setpoint 2. Press the or to change the temperature setpoint, within 5 seconds. After 5 seconds, the last entered setpoint stays in memory. Other Parameters 3. Press to access the other parameters. Each press of the accesses the next parameter. The parameters are: d: differential (-15...15 range) LS: lower set; lower user-access set
ページ18に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 3-5. PROGRAMMING dS: defrost system (computation); dF=digifrost Feature; Continued defrost start time based on total compressor running time rt=real time; defrost start frequency, based on real time dI: defrost interval; defrost frequency in hours, based on the selection of “dS” dE: defrost endurance; total (maximum) length of a defrost cycle, expressed in minutes. (1...99 range) dL: display lock; temperature display is locked during a d
ページ19に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 3-6. FLUORESCENT BULB UL Units REPLACEMENT 1. Pull the bulb out of the sockets. 2. Remove the bulb guard caps. 3. Install new fluorescent bulb in reverse order. CE Units 1. Remove the bulb cover. 2. Rotate the bulb. 3. Pull the lamp out of the sockets. 4. Install new fluorescent lamp in reverse order. 3-7 1102
ページ20に含まれる内容の要旨
Model CMC/CMR-103,104,105,106,107 DIAGRAM FOR CMC MODEL 1002 3-8