Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation/operator's manual included with the dryer. The following “FOR YOUR SAFETY” caution
ページ3に含まれる内容の要旨
IMPORTANT YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUST- ING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STANDARDS. «Attention: Lor des opérations d’entretien des commandes étiqueter tous fils avant “Caution: Label all wires prior to de les déconnecter. Toute erreur de disconnection when servicing co
ページ4に含まれる内容の要旨
WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY or FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation and operator's manual included with the dryer. Dryers must not be installed or stored in an area where it will
ページ5に含まれる内容の要旨
Table of Contents SECTION I IMPORTANT INFORMATION ........................................................................................................ 2 A. RECEIVING and HANDLING.................................................................................................. 2 B. SAFETY PRECAUTIONS ........................................................................................................ 3 SECTION II SPECIFICATIONS/COMPONENT IDENTIFICATION ...................................
ページ6に含まれる内容の要旨
SECTION I IMPORTANT INFORMATION A. RECEIVING and HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves. Dryers damaged in shipment. 1. ALL dryers should be inspected upon receipt and
ページ7に含まれる内容の要旨
B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY or FIRE COULD RESULT. 1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 2. Purchaser or user should c
ページ8に含まれる内容の要旨
7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust duct work, and inside the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING: The collection of lint in the burner area and exhaust duct work can create a potential fire hazard. 8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the National Electric Code ANSI/NFPA NO. 70-LA
ページ9に含まれる内容の要旨
SECTION II SPECIFICATIONS/COMPONENT IDENTIFICATION A. SPECIFICATIONS MAXIMUM CAPACITY (DRY WEIGHT) 95 lbs. 43.1 kg BASKET (TUMBLER) DIAMETER 42" 106.7 cm BASKET (TUMBLER) DEPTH 29-1/4" 74.3 cm BASKET (TUMBLER) MOTOR 1/2 HP .373 kw BLOWER MOTOR 3 HP 2.238 kw DOOR OPENING (DIAMETER) 30-3/4" 78.1 cm BASKET (TUMBLER) VOLUME 23.5 cu. ft. .67cu.m. DRYERS PER 20'/40'' CONTAINER 10/20 DRYERS PER 45'/48' TRUCK 24/24 VOLTAGE AVAILABLE 208-460v / 3ø / 3, 4w / 50/60 Hz APPROX. WEIGHT (UNCRATED) 878 lbs. 4
ページ10に含まれる内容の要旨
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation. 6
ページ11に含まれる内容の要旨
B. COMPONENT IDENTIFICATION 1. Dryer Front View Illus. No. Description 1 Microprocessor Control/Keyboard Panel Assembly (controls) 2 Control (Top Access) Door Assembly 3 Main Door Assembly 4 Lint Panel Assembly 5 Lint Door 6 Wire Diagram (located behind Control Door) 7 Top Console (Module) Assembly 7
ページ12に含まれる内容の要旨
2. Dryer Rear View Illus. No. Description 1 Electrical Service Connections 2 Top Console 3 Heating Unit 4 Relay/Wiring Box 5 Data Label and Installation Label 6 Air Connection 7 Exhaust Transition Piece 8 Optional Exhaust Damper Assembly - if damper option was purchased at time dryer order was placed, the damper must be installed at the time of dryer installation. If damper option was purchased, the damper is shipped inside the dryer tumbler (basket) 8
ページ13に含まれる内容の要旨
SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: National Fuel Gas Code ANSI.Z223.1-LATEST EDITION or National Electric Code ANSI/NFPA NO. 70-LATEST EDITION, or in CANADA, the installation must conform to applicable CANADIAN STANDARDS: CAN/ CGA-B149.1-M91 (Natural Gas). A. LOCATION REQUIREMENTS Before in
ページ14に含まれる内容の要旨
B. UNPACKING/SETTING UP Remove protective shipping material (i.e., plastic wrap, and optional shipping box) from dryer. IMPORTANT: Dryer must be transported and handled in an upright position at all times. The dryer can be moved to its final location while still attached to the skid or with the skid removed. To un-skid the dryer, locate and remove the four (4) bolts securing the base of the dryer to the wooden skid. Two (2) are at the rear base (remove the back panel for access), and two (2)
ページ15に含まれる内容の要旨
1. Leveling Dryer To level dryer, place 4-inch square metal shims (refer to the illustration on page 10) or other suitable material under the base pads. It is suggested that the dryer be tilted slightly to the rear. If more headroom is needed when moving dryer into position, the top console (module) may be removed. a. To remove top console (module). NOTE: DO NOT have power connected when separating the top console. 1) Disconnect the ground wire at the rear of dryer. 2) Remove the six (6) sets
ページ16に含まれる内容の要旨
C. DRYER ENCLOSURE REQUIREMENTS Even though a 30-inch clearance is acceptable, it is recommended that the rear of the dryer be positioned approximately two (3) feet (36-inches) from nearest obstruction (i.e. wall) for ease of installation, maintenance and service. Bulkheads and partitions should be made from noncombustible materials. The clearance between the bulkhead header and the dryer must be a minimum of 4 inches and must not extend more than 4 inches to the rear of the dryer front. The
ページ17に含まれる内容の要旨
D. FRESH AIR SUPPLY When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and sail switch "fluttering" problems may result, as well as premature motor failure from overheating. Air supply (makeup air) must be given ca
ページ18に含まれる内容の要旨
E. EXHAUST REQUIREMENTS 1. General Exhaust Duct Work Information Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct work will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat thermostats. CAUTION: DRYER MUST BE EXHAUSTED TO THE OUTDOORS. CAUTION: IMPROPERLY SIZED OR INSTALLED E
ページ19に含まれる内容の要旨
IMPORTANT: DO NOT use screens or caps on the outside of opening of exhaust duct work. 2. Single Dryer Venting Where possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct should be laid out in such a way that the duct work travels as directly as possible to the outdoors with as few turns as possible. It is suggested that the use of 90° turns in the ducting be avoided; use 30° or 45° angles instead. The shape of the exhaust duct work is not critical so lon
ページ20に含まれる内容の要旨
IMPORTANT: For extended duct work runs, the cross section area of the duct work can only be increased to an extent. Maximum proportional duct work runs cannot exceed twenty (20) feet more than the original limitations of twenty (20) feet with one (1) elbow for horizontal runs and three (3) elbows for vertical runs. When the duct work approaches the maximum limits as noted in this manual, a professional heating, venting and air conditioning (HVAC) firm should be consulted for proper venting inf