ページ1に含まれる内容の要旨
D30
Gas/DSI/Phase 7 Non-Coin with S.A.F.E.
Installation Manual
WARNING: For your safety the information in AVERTISSEMENT: Assurez-vous de bien
this manual must be followed to minimize the suivre les instructions données dans cette notice
risk of fire or explosion or to prevent property pour réduire au minimum le risque d’incendie
ou d’explosion ou pour éviter tout dommage
damage, personal injury or death.
matériel, toute blessure ou la mort.
— Do not store or use gasoline or other flammable —
ページ2に含まれる内容の要旨
Retain This Manual In A Safe Place For Future Reference This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer. The following “FOR YOUR SAFETY” caution must be posted near the dryer i
ページ3に含まれる内容の要旨
IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. «Attention: Au moment de l’entretien des commandes, étiquetez tous les fils avant de “Caution: Label all wires prior to les débrancher. Des erreurs de câblage disconnection when servicing c
ページ4に含まれる内容の要旨
WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer. Dryer must not be installed or stored in an area where it will be exposed to w
ページ5に含まれる内容の要旨
Table of Contents SECTION I IMPORTANT INFORMATION .......................................................................... 3 A. Receiving and Handling ............................................................................................................... 3 B. Safety Precautions ...................................................................................................................... 4 SECTION II SPECIFICATIONS ................................................................
ページ6に含まれる内容の要旨
SECTION VII DATA LABEL INFORMATION ........................................................................ 44 SECTION VIII REVERSING TIMER SPIN/DWELL ADJUSTMENTS .................................. 46 SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS ............................................................ 47 SECTION X SENSOR ACTIVATED FIRE EXTINGUISHING (S.A.F.E.) SYSTEM........... 49
ページ7に含まれる内容の要旨
SECTION I IMPORTANT INFORMATION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves. Dryers damaged in shipment: 1. ALL dryers should be inspected upon receipt and b
ページ8に含まれる内容の要旨
B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. 1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 2. Purchaser/user should cons
ページ9に含まれる内容の要旨
7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard. 8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the National Electrical Code ANSI/NFPA
ページ10に含まれる内容の要旨
SECTION II SPECIFICATIONS A. SPECIFICATIONS BASKET (TUMBLER) DIAMETER 32-3/4” 83.2 cm BASKET (TUMBLER) DEPTH 19” 48.3 cm BASKET (TUMBLER) MOTOR 1/2 hp* 0.373 kW DOOR OPENING (DIAMETER) 21-1/2” 54.61 cm 0.262 cu m BASKET (TUMBLER) VOLUME 9.26 cu ft AIRFLOW (60 Hz) 460 cfm 13.02 cmm 10.93 cmm AIRFLOW (50 Hz) 386 cfm DRYERS PER 20’/40’ CONTAINER 14/30 DRYERS PER 45’/48’ TRUCK 45/45 S.A.F.E. WATER CONNECTION 3/4” M.N.P.T. VOLTAGE AVAILABLE 120-460v 1ø - 3ø 3, 4w 50/60 Hz APPROX. WE
ページ11に含まれる内容の要旨
SPECIFICATIONS – GAS, ELECTRIC, OR STEAM NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. 7
ページ12に含まれる内容の要旨
SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Pro
ページ13に含まれる内容の要旨
B. LOCATION REQUIREMENTS Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1- M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing). 1. The dryer must be installe
ページ14に含まれる内容の要旨
C. DRYER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm) above the dryer’s outer top; 18-inches (45.72 cm) for steam dryers, except along the front of the dryer which may be closed if desired. NOTE: Allowances must be made for opening the control door. X = 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance. * 1-inch (2.54 cm) maximum for electric dryers. ** 18-inch
ページ15に含まれる内容の要旨
D. FRESH AIR SUPPLY REQUIREMENTS The air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1 square foot (0.093 square meters) is required for each dryer. If registers or louvers are installed over the openings, then the area must be increased. It is not necessary to have a separate make-up
ページ16に含まれる内容の要旨
E. EXHAUST REQUIREMENTS Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure, which results in slow drying, increased use of energy, and shutdown of the burner by the airflow (sail) switch, burner hi-limit, or lint chamber hi-heat protector thermostat. The dryer must be installed with a proper exhaust duct connection to the outside. CAUTION: This dryer produces combustible lint and must be exhausted to the
ページ17に含まれる内容の要旨
NOTE: As per the National Fuel Gas Code, “Exhaust ducts for Type 2 clothes dryers shall be constructed of sheet metal or other noncombustible material. Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 0.0195-inches (26 gauge [0.05 mm]) thick.” SINGLE DRYER VENTING IMPORTANT: For exhaust duct runs over 85 feet (25.9 meters) a minimum size of 10-inches (25.4 cm) must be used. HORIZONTAL VENTING When a single 8-inch (20.32 cm
ページ18に含まれる内容の要旨
VERTICAL VENTING When vertical single 8-inch (20.32 cm) venting is used (refer to Illus. B below), the ductwork from the dryer to the outside outlet cannot exceed 55 feet (16.7 meters). This calculation compensates for the use of a maximum of three (3) elbows including the two (2) elbows creating the 180° (turned downward) outside outlet. Illus. B If the length of the ductwork run or quantity of elbows used exceeds the above noted specifications, the cross-sectional area of the ductwork must be
ページ19に含まれる内容の要旨
MULTIPLE DRYER (COMMON) VENTING If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of the airflow. The main common duct may be any shape so long as the minimum cross-sectional area is provided. The main duct should be tapered with the diame
ページ20に含まれる内容の要旨
HORIZONTAL VENTING Illus. C VERTICAL VENTING Illus. D 16