ページ1に含まれる内容の要旨
Installation/Operation
Clothes Dryer
Electric and Gas Models
D709I
Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com.
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 510977R6
March 2008
www.comlaundry.com
PERM PRESS DELICATE
NORMAL FLUFF
(NO HEAT)
IN USE
FABRIC SELECTOR
PUSH TO START
504210
OPERATING INSTRUCTIONS
1. Select Fabric Type (heat setting)
NORMAL, PERM PRESS,
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
WARNING FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. W033 • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. � WHAT TO DO IF YOU SMELL GAS: – Do not try to light any appliance. – Do not touch any electrical switch; do not use any phone in your building. – Clear the room, building or area of all occupants. – Imme
ページ4に含まれる内容の要旨
Safety Information.............................................................................. 4 Table of Explanation of Safety Messages........................................................... 4 Important Safety Instructions ............................................................... 4 Contents Installation........................................................................................... 6 Dimensions .............................................................................
ページ5に含まれる内容の要旨
Operation Instructions for NetMaster Dryers....................................... 35 Step 1: Clean Lint Filter................................................................... 35 Step 2: Load Laundry....................................................................... 35 Step 3: Close Loading Door............................................................. 35 Step 4: Set Fabric Selector............................................................... 36 Step 5: Insert Coin(s) or Card .......
ページ6に含まれる内容の要旨
Safety Information Explanation of Safety Messages Important Safety Instructions Throughout this manual and on machine decals, you Save These Instructions will find precautionary statements (“DANGER,” “WARNING,” and “CAUTION”) followed by specific WARNING instructions. These precautions are intended for the personal safety of the operator, user, servicer, and To reduce the risk of fire, electric shock, those maintaining the machine. or injury to persons when using your dryer, follow these b
ページ7に含まれる内容の要旨
Safety Information 13. Keep area around the exhaust opening and 22. Install this dryer according to the adjacent surrounding area free from the INSTALLATION INSTRUCTIONS. All accumulation of lint, dust and dirt. connections for electrical power, grounding and gas supply must comply with local codes and be 14. The interior of the dryer and the exhaust duct made by licensed personnel when required. Do should be cleaned periodically by qualified not do it yourself unless you know how! servic
ページ8に含まれる内容の要旨
Installation Dimensions 2.0 in. (5.1 cm) 8.0 in. 15.4 in. (20.3 cm) *Electromechanical Models 39.38 in. (100 cm) (39.1 cm) 0.4 in. *Electronic Control Models 36.94 in. (93.83 cm) (1.0 cm) 26.9 in. 28 in. 23.5 in. (68.3 cm) (71.1 cm) (59.7 cm) ELECTRIC MODELS DRY2222N DRY2222N *With leveling legs turned into base. 2.0 in. (5.1 cm) 8.0 in. (20.3 cm) *Electromechanical Models 39.38 in. (100 cm) 0.4 in. 2.3 in. *Electronic Control Models 36.94 in. (93.83 cm) (1.0 cm) (6 cm) 1 15.4 in. (39
ページ9に含まれる内容の要旨
Installation NOTE: Adjust ratchet wheel and timing cam to Additional Security “OFF” position prior to putting dryer into use. Torx security screws are available (as optional Refer to Figure 1 for proper position. equipment at extra cost) for securing lower access panel to dryer base. Order part number 62853. 1 A Torx bit, part number 282P4, is available (as optional equipment at extra cost) for installing the Torx security screws. A Torx bit holder, part number 24161, is available (as opt
ページ10に含まれる内容の要旨
Installation Coin Slide Guards (Coin Slide Models Only) Using sheet metal screws from accessories bag, install coin slide guard, to front of control cabinet. Refer to Figure 2. 1 OPERATING INSTRUCTIONS 1. Select Fabric Type (heat setting) PERM PRESS DELICATE NORMAL, PERM PRESS, DELICATE, FLUFF (no heat) 2. Load Clothes. FLUFF NORMAL (NO HEAT) IN USE 3. Insert Coin(s)/Card. FABRIC SELECTOR 4. To Start Dryer - Close Door and Push Start. 5. To Stop Dryer During Cycle - Open Door. 6
ページ11に含まれる内容の要旨
Installation No other fuel burning appliance should be installed in Before You Start the same closet with the dryer. Tools The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. For most installations, the basic tools you will need are: The dryer needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances 1 2 are shown in Figure 4). Place the dryer
ページ12に含まれる内容の要旨
Installation B E D A *42" (107 cm) A C A 1 FRONT VIEW SIDE VIEW (w/o Closet Door) Area Description Free Standing/Alcove Installation A Dryer sides and rear clearance 0 in. (0 cm) B Dryer top clearance 12 in. (30.5 cm) C Dryer front clearance Not Applicable D Exhaust duct clearance to combustible material 2 in. (5.1 cm) E Weather hood to ground clearance 12 in. (30.5 cm) (Minimum clearances are shown.) D817I * NOTE: For new installations, locate top of wall vent 42 inches (107 cm) above floor to
ページ13に含まれる内容の要旨
Installation Step 2: Connect Dryer Exhaust System ● DO NOT use plastic or thin foil ducting. Rigid metal duct is recommended. WARNING To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors. W604 To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl D740I space under a building or concealed spac
ページ14に含まれる内容の要旨
Installation ● Static pressure in exhaust duct should not be Exhaust Direction greater than .6 inches water column (1.5 cm), The dryer can be exhausted to the outdoors through the measured with manometer placed on exhaust back, left, right or bottom of the dryer. EXCEPTION: duct two feet (61 cm) from dryer (check with Gas dryers cannot be vented out the left side dryer running and no load). In multi-dryer because of the burner housing. installations, all dryers connected to the main coll
ページ15に含まれる内容の要旨
Installation Exhaust System NOTE: Weather hood should be installed at least 12 inches (30.5 cm) above the ground. Larger For best drying results, recommended maximum clearances may be necessary for installations where length of exhaust system is shown in Table 1. heavy snowfall can occur. To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally). Weather Hood Type Number of 90° Elbows Recommended Use Only
ページ16に含まれる内容の要旨
Installation Multi-Dryer Installation Exhaust Requirements Figure 7 shows a typical example of a multiple dryer installation. Note how each dryer has its own exhaust system vented to the central exhaust duct. 2 1 24" (61 cm) MINIMUM CLEARANCE TO ROOF/GROUND METERED MODELS ILLUSTRATED 3 D711I 1 58786 Backdraft Damper (Available through 3 Weather Hood or Sweep Elbow your local authorized parts source) (No cap or screen) 2 Clean Out Cover must be provided. Inspect monthly. Figure 7 510977 ©
ページ17に含まれる内容の要旨
Installation 1 2 A B C D E F G H I J K 5 3 AIR 4 FLOW EXHAUST AIR FLOW 30° MAXIMUM LENGTH OF DUCT 24 in. (61 cm) 30 feet (9.1 m) MINIMUM EXHAUST CLEARANCE TO OUTLET ROOF/GROUND D686I HORIZONTAL EXHAUST INSTALLATION D686I 1 NOTE: Where the exhaust duct pierces a 3 2 in. (5 cm) Minimum or Clearance per Local combustible wall or ceiling, the opening must be Codes sized per local codes. 4 No Screen or Cap 2 Wall 5 Clean Out Cover – Inspect Monthly Figure 8 2 WARNING To reduce the risk of fire
ページ18に含まれる内容の要旨
Installation 1. Make certain your dryer is equipped for use with Minimum Diameter of Duct Station Collector Duct the type of gas in your laundry room. Dryer is equipped at the factory for Natural Gas with a A 4 inches (10.2 cm) 3/8 inch NPT gas connection. B 8 inches (20.3 cm) NOTE: The gas service to a gas dryer must C 9 inches (22.9 cm) conform with the local codes and ordinances, or in D 10 inches (25.4 cm) the absence of local codes and ordinances, with the latest edition of the Natio
ページ19に含まれる内容の要旨
Installation NOTE: When connecting to a gas line, an L.P. Altitude Adjustments equipment shut-off valve must be installed within Altitude Orifice Size 6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug Part No. feet m No. inches mm must be installed as shown for checking inlet 3500 1070 54 0.0550 1.40 503785 pressure. Refer to Figure 10. 7500 2290 55 0.0520 1.32 58755 11000 3355 56 0.0465 1.18 503786 1 Table 3 NOTE: DO NOT connect the dryer to L.P. Gas Service without converting the gas
ページ20に含まれる内容の要旨
Installation Grounding Information ● Heating elements are available for field installation in dryers which are to be connected to ● This dryer must be connected to a grounded electrical service of different voltage than that metal, permanent wiring system; or an listed on nameplate, such as 208 Volt. equipment-grounding conductor must be run ● If branch circuit to dryer is 15 feet (4.57 m) or with the circuit conductors and connected to the less in length, No. 10 AWG wire (copper wire e