ページ1に含まれる内容の要旨
Installation
Mighty Mite and
Super Laundry
Presses
Refer to Page 3 for Model Numbers
SCR1529C
SCR1529C
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
An LSG Company
831 South First Street, P.O. Box 32270
Louisville, KY 40232-2270
Phone: (502) 587-1292
Sales Fax: (502) 585-3625 Part No. AJ1031
February 2005
Service/Parts Fax: (502) 681-1275 www.cissellmfg.com
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Model Identification ........................................................................... 3 Table of Safety Information.............................................................................. 5 Explanation of Safety Messages........................................................... 5 Contents Important Safety Instructions ............................................................... 5 Introduction...................................................................................
ページ4に含まれる内容の要旨
Notes © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 2
ページ5に含まれる内容の要旨
Model Identification Information in this manual is applicable to the following models: LDBB (CMMBB) LDCC (CMMCCY) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 3
ページ6に含まれる内容の要旨
Notes © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 4
ページ7に含まれる内容の要旨
Safety Information Explanation of Safety Messages Important Safety Instructions Precautionary statements (“DANGER,” “WARNING,” Save These Instructions and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These WARNING precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the To reduce the risk of fire, electric shock, machine. serious injury or death to persons when using your press, follow thes
ページ8に含まれる内容の要旨
Safety Information 12. Replace worn power cords and/or loose plugs. Safety signs and labels are also placed on the press. Those signs and labels are limited messages. Where 13. Never operate the press with any guards needed, further explanations are provided in the and/or panels removed. manual. These signs are to be inspected for readability 14. DO NOT operate the press with missing or and replaced when missing, damaged or unreadable. broken parts. Refer to Operation/Maintenance Manual fo
ページ9に含まれる内容の要旨
Introduction Nameplate Location Parts Ordering Information A nameplate is located at the right side of the unit and If literature or replacement parts are required, contact on the pressure arm. Always provide the machine’s the source from which the machine was purchased or serial number and model number when ordering parts contact Cissell at (502) 587-1292 for the name and or when seeking technical assistance. address of the nearest authorized parts distributor. 1 SCR1529C 1 Nameplate Figure
ページ10に含まれる内容の要旨
Notes © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 8
ページ11に含まれる内容の要旨
Installation Front View – Typical Laundry Press 1 10 9 2 8 3 7 4 5 6 SCR95N 1 Pressure Arm 6 Front Cover 2 Right Head CLOSE Pushbutton 7 Head OPEN Pushbutton 3 Timer (Optional on some models) 8 Left Head CLOSE Pushbutton 4 Air Filter/Regulator/Lubricator and Downstream 9 Buck and Padding Relieving Air Shut-Off and Lockout Valve 10 Head 5 Frame Figure 2 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 9
ページ12に含まれる内容の要旨
Installation Front View – Typical Laundry Collar and Cuff Press 1 9 10 2 2 3 3 8 7 4 6 5 SCR548N SCR548N 1 Pressure Arm 6 Cover 2 Cuff Buck 7 Open Pushbutton 3 Close Pushbutton 8 Yoke Rest 4 Timer Control Box 9 Head 5 Air Filter/Regulator/Lubricator and Downstream 10 Collar Buck Relieving Air Shut-Off and Lockout Valve Figure 3 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 10
ページ13に含まれる内容の要旨
Installation Rear View – Typical Laundry Press 8 1 7 2 6 3 5 B0158 4 SCR96N 1 Head Steam Outlet 5 Air Inlet 2 Buck Steam Outlet 6 Electrical Hook-Up (With optional timer) 3 Rear Cover 7 Steam Inlet 4 Anchor Bolt Holes 8 Pressure Arm Figure 4 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 11
ページ14に含まれる内容の要旨
Installation Dimensions and Specifications Laundry Press Net Weights Supply Requirements Steam (Max. Pressure Weight Air 115 psig [7.9 bar]) cu. ft. (cu. m) Model BHP (kw) free air/cycle lbs. (kg) lbs. kg @ 115 psig @ 80 psig conds/hr (7.9 bar) (5.5 bar) LDCC 370 168 1 (.03) .75 (7.35) 26 (12) LDBB 370 168 1 (.03) .75 (7.35) 26 (12) Table 1 Electrical Requirements (Presses With Timers Only) NOTE: Presses without timers do not require electric hook-up. 115 Volt, 230 Volt/60 Hertz/1 Phase, (0.5
ページ15に含まれる内容の要旨
CL CLOSE OSE O OPEN PEN CL CLOSE OSE Installation Overall Dimensions and Connecting Data 36-7/8 in. (93.7 cm) HEAD OPEN 38 in. (96.5 cm) 1-1/2 in. TYP (3.8 cm) 16 in. (40.6 cm) 53 in. (134.6 cm) HEAD OPEN HEIGHT STEAM INLET STEAM INLET 34 in. (86.4 cm) 1 in. TYP 2 in. (2.5 cm) (5.1 cm) 23 in. (58.5 cm) 20 in. (50.8 cm) SCR97N Figure 5 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 13
ページ16に含まれる内容の要旨
Installation 4-3/4 in. (12 cm) 4, 5 1-1/2 in. (3.8 cm) 1-1/2 in. (3.8 cm) 1-1/2 in. (3.8 cm) 3 3-3/4 in. (9.5 cm) 5-1/2 in. (14 cm) 1-1/8 in. (2.9 cm) 2 1 18-1/4 in. (46.4 cm) B0167B SCR98N Figure 6 Above Flat Floor Item Description Connection inches cm 1 Electrical Connection (for presses with timer ONLY) 12 30.5 Refer to Table 2 2 Air Inlet 11 28 1/4 NPT-F 3 Steam Inlet 21.63 55.0 1/2 NPT-F 4 Buck Steam Outlet 21.25 54.0 1/2 NPT-F 5 Head Steam Outlet 23.25 59.0 1/2 NPT-F Table 3 © Copyright,
ページ17に含まれる内容の要旨
Installation Dimensions of Bucks Without Padding 8-1/4 in. 6-1/2 in. (21 cm) (16.5 cm) 13 in. 20-1/2 in. (33 cm) (52 cm) 90° LDCC COLLAR, CUFF & YOKE PRESS 30-1/2 in. (77.4 cm) 10-3/4 in. 13-3/4 in. (27.3 cm) (34.9 cm) SCR558N LDBB BOSOM & BODY PRESS SCR558N Figure 7 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT AJ1031 15
ページ18に含まれる内容の要旨
Installation Required Materials NOTE: Applicable codes, ordinances, specifications and/or other governing data related to installation must be complied with. The materials listed in Table 4 MAY or MAY NOT conform to these requirements. Quantity Description Source 1 Models with timer ONLY. Lockout type fused disconnect switch suitable for Local electric service connected to press (refer to wiring schematic in control box). Not required if circuit breaker is used. As required Models with time
ページ19に含まれる内容の要旨
Installation Location Requirements Installing Anchor Bolts and Levelling Press NOTE: If a forklift is used to move press, exercise care that forklift arms are inserted under frame After press is in position, attach and level it to floor and DO NOT CONTACT ANY OPERATING with four anchor bolts (obtain locally). Using the MECHANISM. frame base anchor bolt holes as a template, drill four holes in floor. Holes must be drilled deep enough to Moving press to installation location while still p
ページ20に含まれる内容の要旨
Installation NOTE: Failure to provide clean, dry air to press Connecting Air Service WILL cause premature valve FAILURE and (Refer to Figure 8) UNNECESSARY DOWNTIME. Air service connected to press must have a A shut-off valve and union placed at each unit is MINIMUM constant pressure of 80 psig (5.52 bar) recommended. and be of ample volume to meet requirements listed in data table (refer to Table 1). Air pressure should be reduced to 75 to 80 psig (5.17 to 5.52 bar) at air inlet regulat