ページ1に含まれる内容の要旨
PHASE 5
COIN
USER’S MANUAL
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: techsupport@amdry.com
www.amdry.com
ADC Part No. 112146-56
ページ2に含まれる内容の要旨
Retain This Manual In A Safe Place For Future Reference Please read this manual carefully to thoroughly familiarize yourself with the Phase 5 Coin computer system features, operational instructions, and programming characteristics. This manual contains important information on how to use ALL the features of your new ADC dryer in the safest and fastest way. American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it
ページ3に含まれる内容の要旨
Table Of Contents SECTION I INTRODUCTION....................................................................................................... 4 Phase 5 Coin Microprocessor Controller (Computer) Features .......................................................... 4 SECTION II L.E.D. DISPLAY AND CODES................................................................................. 8 SECTION III OPERATING INSTRUCTIONS............................................................................. 10
ページ4に含まれる内容の要旨
PL11 - Time For Amount To Start (tFAS) ....................................................................................... 23 PL12 - Amount To Start (AtSt) ....................................................................................................... 23 PL13 - Minimum Amount For Additional Time (AFAT) .................................................................... 23 PL14 - Maximum Time For Automatic Dry (Adrt) ...................................................................
ページ5に含まれる内容の要旨
SECTION VII FACTORY PRESET PROGRAMS/PARAMETERS.......................................... 51 A. Single Coin Only For all dryer models except AD-26/AD-295 and AD-540/WDA-540 ....................................... 52 B. Dual Coin Only For all dryer models except AD-26/AD-295 and AD-540/WDA-540 ....................................... 53 C. Single Coin Only For dryer models AD-26/AD-295 Only .................................................................................... 54 D. Dual Coin Only For
ページ6に含まれる内容の要旨
SECTION I INTRODUCTION The Phase 5 Coin Computer System is a fully programmable, highly sophisticated dryer control system. American Dryer Corporation has designed the Phase 5 coin microprocessor controller (computer) to be the most versatile and reliable coin-operated control system available. To eliminate as many moving parts as possible, ALL Phase 5 coin microprocessor controller (computer) programming is done through the membrane switch on the front of the control panel. The Program Switch
ページ7に含まれる内容の要旨
TIME FOR AMOUNT TO START This program retains the time the owner wishes to vend. The feature allows any additional purchase that is made to be calculated to the second. There is no calculation necessary by the owner. The Phase 5 coin microprocessor controller (computer) calculates the vended time. ACCUMULATIVE COIN This program selection requires that a specific value of coin(s) be inserted for additional time, programmable for any minimum amount. COIN COUNT The number of coins inserted, incl
ページ8に含まれる内容の要旨
COOL DOWN TIME ALL three (3) temperature selections are programmable from a minimum of 0 minutes to a maximum of 9 minutes in 1 minute increments. COOL DOWN TEMPERATURES In the automatic or free dry modes, the cool down cycle termination is programmable from a minimum of 70° F to a maximum of 190° F in ten-degree increments or from a minimum of 21° C to a maximum of 88° C in five-degree increments. AUTOMATIC MODE (Patent No. 4,827,627) This program selection uses ADC’s patented Auto-Dry cycle.
ページ9に含まれる内容の要旨
TEMPERATURE DISPLAY This program selection enables the temperature in the dryer to be viewed (°F or °C) either while the dryer is off or running. This service feature shows that the dryer is maintaining the selected temperature. DIAGNOSTICS ALL major circuits, including door, microprocessor temperature sensor, heat, and motor circuits are monitored. There are also indicators installed on the outputs of each relay to easily identify failures, and the door switch has an indicator installed on the
ページ10に含まれる内容の要旨
SECTION II L.E.D. DISPLAY AND CODES A Automatic Cycle (Slope Program Factor) ACOn Accumulative Coin Adrt Maximum Auto Dryness Time AFAt Amount for Additional Time AGt Active Anti-Wrinkle Guard Time AtIn Accumulative Time AtSt Amount To Start AUtO Automatic Mode (Patent No. 4,827,627) b Automatic Cycle (Heat Loss [offset] Factor) bCLO Bad Coin Lockout bCrS Bad Coin Reset bUZ Buzzer (Tone) o CEL Degree in Celsius CLCC Clear Left Coin Count Coin Coin Mode CrCC Clear Right Coin Count donE Drying and
ページ11に含まれる内容の要旨
Grd Anti-Wrinkle Program Active HICd High Cool Down Hot Overheating Condition* LCC Left Coin Count LCdE Left Coin Denomination LOCd Low Cool Down nbUZ No Buzzer (Tone) nFLS No Flash Display nGrd No Anti-Wrinkle nSEn No Rotational Sensor Selected PdrY Percent Dry PL Program Location PLOC Program Location Automation Review PPCd Permanent Press Cool Down PP°F Permanent Press PUSH Amount To Start Has Been Inserted Make Temperature Selection rCC Right Coin Count rCdE Right Coin Denomination SEFL Rota
ページ12に含まれる内容の要旨
SECTION III OPERATING INSTRUCTIONS NOTE: Unless otherwise specified at the time of ordering, the Phase 5 coin microprocessor controller (computer) has been preprogrammed by the factory with the parameters shown on page 52 and page 53 (for ALL dryer models except AD-26/AD-295 and AD-540/WDA-540) and page 54 and page 55 (for dryer models AD-26/AD-295 and AD-540/WDA-540 only). Should program changes be found necessary, please read this Phase 5 Coin User’s Manual carefully to thoroughly familiarize
ページ13に含まれる内容の要旨
B. AUTOMATIC MODE (PATENT NO. 4,827,627) 1. When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read “FILL” and/or “Amount To Start” (“AtSt”). 2. Insert coin(s). Once correct “Amount To Start” has been inserted, the L.E.D. display will read “PUSH.” 3. Select temperature by pushing “HI TEMP,” “LO TEMP,” or “PERM PRESS.” The dryer will start, the L.E.D. display will read the temperature cycle selected, and the drying time portion of the L.E.D. d
ページ14に含まれる内容の要旨
C. FREE DRY MODE 1 When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read “FILL” and/or “FrEE.” 2. Select temperature. The dryer will start, the L.E.D. display will read the temperature cycle selected and the drying time portion of the L.E.D. display will read the temperature cycle selected. The drying time portion of the L.E.D. drying will read “00” and count upward as time elapses, or the vended time will count downward, depending on which
ページ15に含まれる内容の要旨
SECTION IV PROGRAM SELECTION NOTE: Programs are stored in the Phase 5 coin microprocessor controller (computer) memory and are cataloged as Program Locations (PL). TEMPERATURE DISPLAY MODE By closing the Program Switch (PS) located on the back side of the Phase 5 coin microprocessor controller (computer), the light emitting diode (L.E.D.) display will read the temperature in the dryer in either Fahrenheit (°F) or Celsius (°C), depending on how the temperature conversion status is in PL01. The t
ページ16に含まれる内容の要旨
AUTOMATIC REVIEW OF PROGRAM LOCATION This selection allows for the AUTOMATIC REVIEW of what the program locations are set (programmed) for, thereby eliminating the need to go into each and every Program Location (PL) manually for verification. By closing the Programming Switch (PS) with no cycle in progress, the light emitting diode (L.E.D.) display will read the temperature in the dryer. Then, by pressing the “LO TEMP” key, the L.E.D. display will read “PLOC” for 1-second. Then, the Phase 5
ページ17に含まれる内容の要旨
PL01 - TEMPERATURE CONVERSION STATUS This program controls whether the temperature related programs will be operated in Fahrenheit (°F) or Celsius (°C). The programs affected are: 1. Temperature Display Mode 2. Selection Cycling Temperatures 3. Cool Down Temperatures AUTOMATIC MODE (AUtO) Patent No. 4,827,627 When this parameter (“AUtO”) is selected, the dryer will run for a preset level of dryness (PL02) or until the programmed automatic maximum time (PL14) has expired. At the end of the dryin
ページ18に含まれる内容の要旨
ANTI-WRINKLE PROGRAM (Grd) This feature can be used in conjunction with any of the three (3) operating modes (Coin Mode, Auto Mode, or the Free Dry Mode). In this program (“Grd”), when the drying and cooling cycles are completed, the dryer will shut off, the buzzer (tone) will sound, and the light emitting diode (L.E.D.) display will read “donE.” If the door is not opened, the Phase 5 coin microprocessor controller (computer) will wait until the “Guard Delay Time” (PL15) has expired, at which
ページ19に含まれる内容の要旨
COIN MODE (COIN) In this program mode (“Coin”), coins are required to start the dryer, even if the Phase 5 coin microprocessor controller (computer) is set in the Automatic Mode (Patent No. 4,827,627). NOTE: When programming the use of the Coin Mode, (“Coin”), the following parameter/programs need to be checked and/or changed accordingly: PL01 ................................ “AUtO” (automatic drying cycle) or ................................ “tInE” (timed drying cycle) “FrEE” PL02* ............
ページ20に含まれる内容の要旨
ACCUMULATIVE TIME (AtIn) (SINGLE COIN) In this program mode (“AtIn”), each coin inserted has a specific value in time which is determined by the “Time For Amount To Start” (“tFAS”) program (PL11). Example No. 1: If the dryer is equipped with a 25¢ coin acceptor and the desired time is 30 minutes, each additional coin inserted would yield 30 minutes. Settings: PL09 (LCdE)........................25 PL11 (tFAS) ..........................30 PL12 (AtSt)...........................25 Example No. 2: If