ページ1に含まれる内容の要旨
Operating Instructions (ENG)
MODELS: RMBS12 BEFORE S/N12236
RMBS16 BEFORE S/N 16905
Read instructions before operating the machine.
J
980124 09/20/05
ページ2に含まれる内容の要旨
MACHINE DATA LOG/OVERVIEW MODEL _______________________________________ DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________ SALES REPRESENTATIVE # _____________________ DEALER NAME ________________________________ OPERATIONS GUIDE NUMBER ___________________ PUBLISHED __________________________________________ Copyright 2003 Windsor Industries, Printed in USA YOUR DEALER Name: ___________________________________________________________________
ページ3に含まれる内容の要旨
TABLE OF CONTENTS Machine Data Log/Overview. ......................2 GROUP PARTS LIST Table of Contents........................................3 Handle Group..............................................5-1 HOW TO USE THIS MANUAL Base - Motor Group....................................5-3 Base - Brush Group....................................5-5 Notes...........................................................5-7 How to use this Manual...............................1-1 Warranty.....................
ページ4に含まれる内容の要旨
HOW TO USE THIS MANUAL The PARTS LIST section contains assembled This manual contains the following sections: parts illustrations and corresponding parts list. The parts lists include a number of columns of - HOW TO USE THIS MANUAL information: - SAFETY - OPERATIONS - REF – column refers to the reference - MAINTENANCE number on the parts illustration. - PARTS LIST - PART NO. – column lists the part number for the part. The HOW TO USE THIS MANUAL section will tell - QTY – column lists the quantit
ページ5に含まれる内容の要旨
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. ! WARNING: To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. See Grounding Instructions. Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service. Do not allow machine to be used as
ページ6に含まれる内容の要旨
HAZARD INTENSITY LEVEL The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: ! WARNING WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death. ! CAUTION CAUTION - Hazards or unsafe practices which could result in minor perso
ページ7に含まれる内容の要旨
GROUNDING INSTRUCTIONS THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors. Improper connection of the equipment- EXTENSION CORDS: grounding conductor can result in a risk of If an extension cord is used, the wire size electr
ページ8に含まれる内容の要旨
TECHNICAL SPECIFICATIONS ITEM DIMENSION/CAPACITY Electrical 115V Nominal Power 550W Rated Amperage 7 Amps Brush Width - RMBS12 12 inches (30 cm) - RMBS16 16 inches (40 cm) Brush RPM 600 RPM Wheels 3 inches (7.5 cm) non-marking grey Dimensions – Weight - RMBS12 40 lbs. (18kg) - RMBS16 44 lbs. (20kg) Dimensions – Height - with handle 44 inches (112 cm) Dimensions – Depth 12 inches (30 cm) Power Cord 33 feet (10 m) ROMBUS 980124 07/02/03 3-1
ページ9に含まれる内容の要旨
HOW THE MACHINE WORKS Congratulations! You are now the proud owner of a Windsor Rombus Carpet Maintainer. The Windsor Rombus Carpet Maintainer is designed to maintain your carpet using the Rombus Quick Clean, Quick Dry Carpet Care System. By using the Rombus Carpet Maintainer in conjunction with Windsor Red Carpet Rombus Carpet Clean (W145-4) chemical solution, you can perform a regular light cleaning and grooming of your carpet very quickly, and have the carpet dry and ready for traffic within
ページ10に含まれる内容の要旨
MACHINE OPERATION PRE-RUN MACHINE INSPECTION MACHINE SHUT-DOWN AND Perform a pre-run inspection to find possible STORAGE problems that could cause poor performance or lost time from breakdown. Check the rating plate 1. Depress the foot switch to power off to confirm voltage and frequency is the same as machine. the power supply. NOTE: A 10% variation in voltage is acceptable. 2. Lock handle in the upright position. STARTING MACHINE 3. Disconnect the power cord from the power NOTE: Perform pre-r
ページ11に含まれる内容の要旨
MAINTENANCE BRUSH CLEANING AND DAILY MAINTENANCE MAINTENANCE 1. Clean and inspect brushes. After each session or carpet cleaning, the brushes 2. Clean and inspect brush housing and and the brush housing should be cleaned. Before machine. cleaning or changing the brushes, always unplug the machine from the power supply. 3. Inspect power cord for wear or damage. This cable will lie on wet carpet. To prevent Brushes are removed without tools. Tilt and rest electrical shock replace cords that are
ページ12に含まれる内容の要旨
MACHINE TROUBLESHOOTING PROBLEM CAUSE SOLUTION No power to machine Dead electrical circuit Check building circuit breaker in fuse box breaker Faulty power cord Replace power cord Power switch failure Replace power switch Faulty circuit breaker Replace circuit breaker Internal wiring problem With machine unplugged, check for and correct, any loose wire connections. Electrical Shock Equipment not grounding Follow grounding instructions, pg 2-3 Receptacle not grounded Have an electrician inspect th
ページ13に含まれる内容の要旨
THIS PAGE LEFT BLANK INTENTIONALLY ROMBUS 980124 07/02/03 4-3
ページ14に含まれる内容の要旨
HANDLE 3 6 5 4 19 25 1 NOTE: The handle view is shown from the 18 Rear. This is to help clarify how the components are attached to the handle asm. 26 28 10 8 9 7 4 27 17 11 12 21 15 22 24A 24B 13 14A 14B 20A 16 23 20B ROMBUS 980124 09/22/04 5-1
ページ15に含まれる内容の要旨
HANDLE SERIAL NO. REF PART NO. QTY DESCRIPTION NOTES: FROM 1 RMH 1 RMBS HANDLE ASM CMPLT 2 01014 1 CABLE RESTRAINT NOT SHOWN 3 01004 2 HANDLE GRIPS 4 01008 2 CAP PLUG 5 01009 1 CAP SCREW 6 01007 1 UPPER CABLE HOLDER, LOCKED 7 01088 1 CAP SCREW 8 01011 1 LWR CABLE HLDR, GYRATORY 9 01012 1 GYRATORY CBL RTNR SPRING 10 01013 1 BALL BEARING 11 01021 2 NYLON, INSERT NUT 12 01018 2 HANDLE BLOCKS 13 01017 1 5MM PINS 14A 01097 1 RMBS12 HANDLE BAR (MCHN SD) R
ページ16に含まれる内容の要旨
BASE - MOTOR 1 2A 2B 3 38 32 33 31 34 29 31 25 26 37 4 24 8 36 5 33 11 32 6 35 28 26 27 28 12 7 27 30 24 23 21A 8 22 21B 19 20 9 10 13A 18 13B 17 16 15A 15B 14A 14B ROMBUS 980124 12/18/03 5-3
ページ17に含まれる内容の要旨
BASE - MOTOR SERIAL NO. REF PART NO. QTY DESCRIPTION NOTES: FROM 1 01042 8 BUTTON SCREWS 2A 01026 1 RMBS12 MCHN COVER RMBS12 ONLY 2B 01037 1 RMBS16 MCHN COVER RMBS16 ONLY 3 01070 1 CABLE 10M 4 01069 1 MOTOR CABLE 1M 5 01076 1 CABLE GLAND 6 01068 1 SWITCH LOCKING NUT 7 01067 1 SWITCH 8 01054 3 SCREW 9 01063 1 END HOUSING 10 01071 2 SCREW 11 01062 1 THERMAL RESET SWITCH COVER 12 01061 1 THERMAL RESET SWITCH 13A 01030 2 RMBS12 DRAW BARS RMBS12 ONLY 13B
ページ18に含まれる内容の要旨
BASE - BRUSH (END 2 HOUSING) 1 6A 6B 7A 7B 5 4A 4B 3 13 8A 8B 9A 9B 10A 10B 12 11 ROMBUS 980124 02/19/04 5-5
ページ19に含まれる内容の要旨
BASE - BRUSH SERIAL NO. REF PART NO. QTY DESCRIPTION NOTES: FROM 1 01059 2 NYLON BRUSH SHFT HSNG 2 01060 2 BEARING 3 01031 2 CAP SCREW 4A 01022 2 RMBS12 BRUSH SHAFT ASM RMBS12 ONLY 4B 01033 2 RMBS16 BRUSH SHAFT ASM RMBS16 ONLY 5 01032 2 SPRING LOADED PIN 6A 01029 1 RMBS12 SPLASH GUARD RMBS12 ONLY 6B 01040 1 RMBS16 SPLASH GUARD RMBS16 ONLY 7A 01002 2 BRUSH, STANDARD WHT 12” (PAIR) RMBS12 ONLY 7B 01003 2 BRUSH, STANDARD WHT 16” (PAIR) RMBS16 ONLY 8A 01028 2 RMBS12 CA
ページ20に含まれる内容の要旨
NOTES ROMBUS 980124 07/02/03 5-7