ページ1に含まれる内容の要旨
Model APS-155
Installation Manual
SELECTABLE FEATURES
Note : When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver’s door pin
switch in order to begin the passive arming sequence.
RF Programmable Features :
Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps Default
1st Door L/UL 1 Sec. 3.5 Sec. 1 Sec L, Dbl. U/L 1 Sec.
2nd Accy Lock Auto Lock On Auto Lock Off Auto Lock Off
3rd Accy. UL Auto UL On Auto UL Off Auto UL Off
4th Passive Locks Passive Active Active
ページ2に含まれる内容の要旨
Seventh Press and release the valet switch 1 chirp = siren and horn output Press transmitter Lock button to change 2 chirps = siren output only Press transmitter lock button to change 3 chirps = horn output only or Eighth Press and release the valet switch 2 chirps = horn chirp output 16mS Press transmitter Lock button to change 3 chirps = horn chirp output 30mS Press transmitter Lock button to change 1 chirp = horn chirp output 10 mS or Ninth Press and release the valet switch 2 chirps = valet
ページ3に含まれる内容の要旨
an even higher level of security to the vehicle. The valet switch can be mounted to the lower side of the dash by drilling a ¼ “ diameter hole in the selected location. Be sure to check behind the dash for adequate clearance for the body of the switch, and to confirm that the drill will not damage any existing components as it passes through the dash. You should also make certain that the back of the switch is accessible for wiring later in the installation. Shock Sensor : Select a solid mountin
ページ4に含まれる内容の要旨
Brown Wire : - DOOR TRIGGER If the vehicle’s courtesy light switches have a ( - ) ground output when the door is opened ( GM and most Imports ), you must connect this wire to the negative output from one of the door switches. WARNING : Do not use the brown wire if the vehicle has + 12 volt output type door switches. ( see Purple Wire ). Purple Wire : + DOOR TRIGGER If the vehicle’s door courtesy light switches have a + 12 volt output when the door is opened ( most Fords and some Imports ), you m
ページ5に含まれる内容の要旨
Red & Green 2 Pin White Connector : DOOR LOCK OUTPUTS These wires will provide either a pulsed ground output to the factory door lock control relay, or a pulsed + 12 volt output to the factory door lock control relay. In either case, the maximum current draw through these outputs must not exceed 300 mA. 3 Wire Ground Switched Door Locks In this application, the red wire provides a ground pulse during arming, or the pulsed ground lock output. Connect the red wire to the wire that provides a low c
ページ6に含まれる内容の要旨
© 2000 Audiovox Corp., 150 Marcus Blvd., Hauppauge, N.Y. 11788 128-5733A