ページ1に含まれる内容の要旨
OM-356 188694J
October 2000
Processes
TIG (GTAW) Welding
Stick (SMAW) Welding
Description
Arc Welding Power Source
CYBERTIG 350LX
And Non-CE Models
Visit our website at
www.HobartWelders.com
ページ2に含まれる内容の要旨
From Hobart to You Thank you and congratulations on choosing Hobart. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. This Owner’s Manual is designed to help you get the most out of your Hobart products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve made installation and operation quick and easy. With Hobart you can count on years of reliable service with
ページ3に含まれる内容の要旨
TABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 The following terms are 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 used interchangeably 1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 throughout this manual: TIG = GTAW 1-
ページ4に含まれる内容の要旨
ページ5に含まれる内容の要旨
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. This group of symbols means Warning! Watch Out! possible Marks a special safety message. ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions Means “Note”; not safety related. to avoid the hazards. 1-2. Arc Welding
ページ6に含まれる内容の要旨
ARC RAYS can burn eyes and skin. BUILDUP OF GAS can injure or kill. Shut off shielding gas supply when not in use. Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays Always ventilate confined spaces or use that can burn eyes and skin. Sparks fly off from the approved air-supplied respirator. weld. Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87.1 li
ページ7に含まれる内容の要旨
1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. MOVING PARTS can cause injury. Do not install or place unit on, over, or near Keep away from moving parts such as fans. combustible surfaces. Keep all doors, panels, covers, and guards Do not install unit near flammables. closed and securely in place. Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit. FALLING UNIT can cau
ページ8に含まれる内容の要旨
1-5. EMF Information Considerations About Welding And The Effects Of Low Frequency 1. Keep cables close together by twisting or taping them. Electric And Magnetic Fields 2. Arrange cables to one side and away from the operator. Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 3. Do not coil or drape cables around your body. years of resea
ページ9に含まれる内容の要旨
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives. Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des Identifie un message de sécurité particulier. risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous au
ページ10に含まれる内容の要旨
LES RAYONS DE L’ARC peuvent pro- LES ACCUMULATIONS DE GAZ ris- voquer des brûlures dans les yeux et quent de provoquer des blessures ou sur la peau. même la mort. Le rayonnement de l’arc du procédé de soudage Fermer l’alimentation du gaz protecteur en cas de génère des rayons visibles et invisibles intenses non utilisation. (ultraviolets et infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées Veiller toujours à bien aérer les espaces
ページ11に含まれる内容の要旨
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU DES ORGANES MOBILES peuvent D’EXPLOSION. provoquer des blessures. Ne pas placer l’appareil sur, au-dessus ou à proxi- Rester à l’écart des organes mobiles comme le mité de surfaces infllammables. ventilateur. Maintenir fermés et fixement en place les portes, Ne pas installer l’appareil à proximité de produits inflammables panneaux, recouvrements et dispositifs de Ne pa
ページ12に含まれる内容の要旨
1-4. Principales normes de sécurité Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel- Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, ding Society, 550 N.W. Lejeune Rd, Miami FL 33126 de la Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202. Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. Règles de sécurité en soudage, coupage et procédés conne
ページ13に含まれる内容の要旨
SECTION 2 – DEFINITIONS 2-1. Warning Label Definitions Warning! Watch Out! There are possible hazards as shown by the symbols. 1 Electric shock from welding electrode or wiring can kill. 1.1 Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. 1.2 Protect yourself from electric shock by insulating yourself from work and ground. 1.3 Disconnect input plug or power before working on machine. 2 Breathing welding fumes can be hazardous to your health.
ページ14に含まれる内容の要旨
2-2. Manufacturer’s Rating Label For CE Products OM-356 Page 10
ページ15に含まれる内容の要旨
2-3. Symbols And Definitions Some symbols are found only on CE products. NOTE Gas Tungsten Arc Shielded Metal Arc Amperes Panel–Local Welding (GTAW) Welding (SMAW) A Do Not Switch Volts Arc Force (DIG) Spot Timer V While Welding Output Circuit Breaker Remote Temperature Protective Earth High Frequency - Alternating Current Input (Ground) Start High Frequency - Postflow Timer Preflow Timer High Frequency Continuous Increase/Decrease Gas (Supply) Gas Input Gas Output Of Quantity On Off Percent Dir
ページ16に含まれる内容の要旨
SECTION 3 – INSTALLATION 3-1. Selecting A Location Falling Unit Can Cause Injury. Use lifting eye to lift unit only, NOT running gear, gas cylinders, or any other Movement accessories. Use equipment of adequate 1 capacity to lift and support unit. If using lift forks to move unit, be sure forks are long enough to extend beyond opposite OR side of unit. 2 1 Lifting Eye 2 Lifting Forks Use lifting eye or lifting forks to move unit. If using lifting forks, extend forks beyond opposite side
ページ17に含まれる内容の要旨
3-2. Dimensions And Weights Dimensions A 38-1/4 in (972 mm) with retract- Height able lifting eye down B B D C Width 22-1/2 in (572 mm) Length 25 in (635 mm) A 25 in (635 mm) B 23-5/8 in (600 mm) E C 1-3/8 in (35 mm) Front F D 7/8 in (22 mm) E 19-15/16 (506 mm) F 22-1/4 (565 mm) G 1/2 in (13 mm) Dia Weight Ref. ST-184 046 G 4 Holes 515 lbs (234 kg) 3-3. Specifications Amperes Input at AC Balanced Rated Load Output, Amperage Max Rated 50/60 Hz, Single-Phase Range OCV Welding PFC 200V 220V 230V 40
ページ18に含まれる内容の要旨
3-4. Duty Cycle And Overheating Duty Cycle is the percentage of 10 minutes that the unit can weld at rated load without overheating. If unit overheats, output stops, front panel voltmeter/ammeter displays a HLP3 or HLP5 message (see Section 5-4), and cooling fans run. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle be- fore welding. Exceeding duty cycle can damage unit and void war- ranty. 40% Duty Cycle At 350 Amperes (60 Hz Models Only) 60% Duty Cycle At 300 Amperes 6 Mi
ページ19に含まれる内容の要旨
3-6. Weld Output Terminals And Selecting Cable Sizes ARC WELDING can cause Electromagnetic Interference. To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shiel
ページ20に含まれる内容の要旨
3-8. Shielding Gas Connections And 115 Volts AC Duplex Receptacle Turn Off power before con- necting to receptacle. 1 Gas Valve In Fitting Located on rear of unit. 2 Gas Valve Out Fitting 4 Fittings have 5/8-18 right-hand threads. 3 Cylinder Valve 3 5 Open valve slightly so gas flow blows dirt from valve. Close valve. 4 Regulator/Flow Gauge Connect regulator/flow gauge to gas cylinder. Connect customer supplied gas hose between regulator/flow gauge and gas in fitting. 5 Flow Adjust Typical flo