ページ1に含まれる内容の要旨
Advanced Weather Station with Wireless
INTRODUCTION
Sensor Set & Mounting Package Thank you for selecting the Oregon Scientific™ Weather
Station (WMR100N / WMR100NA).
Model: WMR100N / WMR100NA
The base station is compatible with other sensors. To
USER MANUAL
purchase additional sensors, please contact your local
retailer.
CONTENTS
Introduction ............................................................... 1
Sensors with this logo are compatible with this
Packaging Contents .............
ページ2に含まれる内容の要旨
ACCESSORIES - SENSORS This product can work with up to 10 sensors at any one time to capture outdoor temperature, relative humidity or UV readings in various locations. 4 x Screws (Type A) Optional wireless remote sensors such as those listed below can be purchased separately. For more 1 x information, please contact your local retailer.* Temperature 1 x Temperature / Humidity / Humidity 1 x sensor Sensor casing • Solar Panel STC800 connectable to Wind Sensor and Sensor connector T
ページ3に含まれる内容の要旨
Temperature / Heat Index / Wind Chill Area BACK VIEW 1 2 3 4 5 1 2 3 7 6 4 5 7 6 8 9 1. Temperature trend 1. AC adapter socket 2. Wind Chill level - temperature is showing 2. RESET: Returns unit to default settings 3. Heat Index level - temperature is showing 3. SEARCH: Searches for sensors or for the radio- 4. HI / LO temperature, HI Heat Index and LO Wind Chill controlled clock signal alarms are set 4. UNIT: Selects unit of measurement 5. Selected area icon 5. Battery compartment 6. Indoor
ページ4に含まれる内容の要旨
4. Rain rate is showing WIND SENSOR 5. UVI / barometric pressure (mmHg, inHg or mb / hPa)/ rainfall readings (in / hr or mm / hr) 1 6. UVI level indicator 7. Accumulated rainfall is showing 8. Past 24hrs rainfall is showing 2 9. Altitude is showing 4 10. UVI / barometric pressure / rainfall historical bar chart display Clock / Alarm / Calendar / Moon Phase Area 1 4 2 5 3 3 6 1. Clock radio reception 1. Wind direction 2. Alarm 1 and 2 are displayed and set 2. Wind vane casing 3. Timestamp is d
ページ5に含まれる内容の要旨
OUTDOOR TEMPERATURE / HUMIDITY SENSOR 1 3 3. Slide wind vane onto the end of the plastic attachment located on the aluminium pole. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. 3 2 4 SET UP REMOTE TEMPERATURE / HUMIDITY SENSOR 1. Temperature / humidity sensor casing 2. Solar power socket 3. RESET button 4. Battery compartment GETTING STARTED 2 3 SET UP REMOTE WIND SENSOR 1 The wind sensor takes wind speed and direction re
ページ6に含まれる内容の要旨
To mount the wind sensor: 3. Insert the versatile plastic base into the pole. Align the holes of the pole with the holes of the plastic base. 4. Secure the plastic base by inserting the screw and screwing it tightly into the holes of the plastic base and pole. 13 IMPORTANT The 14 sensor should be positioned in an open area away from trees or 13. Insert the wind vane into the attachment bracket. other obstructions. 14. Screw aluminium pole firmly into place. IMPORTANT For best result
ページ7に含まれる内容の要旨
To set up the Rain Gauge: 6 16 4 2 1 5 4. Insert wind sensor into the top of the bracket. 5. Using screws, fix aluminium pole firmly into place. 1. Remove screws and slide the cover off in an upwards 6. Slide outdoor sensor onto bracket. motion. 2. Insert the batteries (2 x UM-3 / AA), matching the polarities (+ / -). Press RESET after each battery IMPORTANT For best results, point the wind vane North. change. 3 3. Remove the fibre tape. ALTERNATIVE SET UP: TEMPERATURE / HUMIDITY SENSO
ページ8に含まれる内容の要旨
SET UP BASE STATION BASE STATION NOTE Install batteries in the remote sensor before the CHANGE DISPLAY / SETTING base station matching the polarities (+ and -). To change the display and settings, use the following buttons on the rotating dial: SELECT, MEMORY / ON / OFF, MODE and ALARM. In addition, the UNIT and SEARCH buttons located at the bottom of the base station allows pre-setting of the remote sensor channels and the For continuous use, please install the AC adapter. The mea
ページ9に含まれる内容の要旨
To activate / deactivate an alarm: NOTE For best reception, the base station should be 1. Press SELECT to navigate to the Clock Area. will placed on a flat, non-metallic surface near a window in an upper floor of your home. The antenna should be placed show next to the Area. away from electrical appliances and not be moved around 2. Press ALARM to toggle between alarm 1 and when searching for a signal. alarm 2 . 3. Press MEMORY / ON / OFF to activate or CLOCK / CALENDAR deactivate the
ページ10に含まれる内容の要旨
To clear the memories and timestamp for the TEMPERATURE AND HUMIDITY temperature, heat index, wind chill, humidity and The weather station displays indoor and outdoor dew point readings: readings for: In the Temperature or Humidity Area, press and hold 1. Current, minimum and maximum temperatures and MEMORY / ON / OFF to clear the readings. relative humidity. 2. Comfort level indicator and trend line. To change the high / low temperature, heat index, 3. Heat index, wind chill and dew po
ページ11に含まれる内容の要旨
To select the wind speed unit: of UV index, and 24 hours of rainfall and barometric pressure readings. Press UNIT (at the bottom of the base station) to switch between: UVI BAROMETER RAINFALL • Metres per second (m / s) • Kilometers per hour (kph) • Miles per hour (mph) • Knots (knots) The wind level is shown by a series of icons: ICON LEVEL DESCRIPTION The bar chart display shows the current and historical data for the UV index, barometric pressure and rainfall N/A <2 mph (<4km/h) readin
ページ12に含まれる内容の要旨
2. Rotate the dial left or right to set the desired values. 3. Press ALARM to confirm the settings. 3. Press ALARM to confirm the settings. To activate / deactivate the HI rainfall rate alarm: To activate / deactivate the high UV alarm: 1. In the UV / Barometer / Rainfall Area and Rainfall 1. In the UV / Barometer / Rainfall Area and UVI reading reading display, press ALARM repeatedly to select display, press ALARM repeatedly to select the the desired alarm. desired alarm. 2. Press MEMORY / O
ページ13に含まれる内容の要旨
4. Double click on Change your Windows password. 5. In new dialogue box Power Options Properties, click (If you chose the Control Panel classic link from left on Power Schemes tab. hand column in step 2, skip this step). 6. In Settings for Timers off (Presentation) power 5. In Turn User Account On or Off screen, identify if scheme section, under System Standby option, UAC option is enabled / on (ticked) or disabled / off choose Never in drop-down list. (un-ticked). 7. Click Apply and the
ページ14に含まれる内容の要旨
Operating range -30°C to 60°C (-4°F to 140°F) downloadable from the software webpage. Accuracy 0°C - 40°C: +/- 1°C (+/- 2.0°F) IMPORTANT You must first successfully install software to access the PC Software Manual. 40°C - 50°C: +/- 2°C (+/- 4.0°F) Comfort 20°C to 25°C (68°F to 77°F) 1. In the PC software homepage, click on MENU Memory Current, Min and Max temp. located at the top right hand corner of software main Dew Point w/ Min and Max webpage. 2. Select HELP from drop-down list. This w
ページ15に含まれる内容の要旨
Operating range -30°C to 60°C (-4°F to 140°F) over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive Accuracy -20°C – 0°C: +/- 2°C (+/- 4.0°F) materials. 0°C - 40°C: +/- 1°C (+/- 2.0°F) • Do not tamper with the unit’s internal components. 40°C - 50°C: +/- 2°C (+/- 4.0°F) This invalidates the warranty. 50°C - 60°C: +/- 3°C (+/- 6.0°F) • Only use fresh batteries. Do not mix new and old Comfort 20°C to 25°C (68°F to 77°F) batteries. Memory C
ページ16に含まれる内容の要旨
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE This equipment has been tested and found