ページ1に含まれる内容の要旨
Temperature measuring units (ºF/ºC) 26
WS-9049 WEATHER STATION
Instruction Manual Air pressure measuring Units (inHg/hPa) 26
Relative pressure setting 27
TABLE OF CONTENTS
Forecast sensitivity setting 28
Topic Page
Alarm (setting and snooze) 29
Inventory of Contents 3
Moon phases 30
Features 4
Indoor temperature and humidity 31
Setting up 6
Comfort indicator 32
WWVB radio controlled time 14
Toggling and resetting the indoor data 33
Function keys 15
Weather forecast tendency
ページ2に含まれる内容の要旨
Displays Weekday with Date Thermo-Hygro Transmitter Alarm with snooze function Displays 12 Moon phases throughout the year Remote transmission of outdoor Weather forecasting with weather tendency indicator temperature and humidity to weather station by 915 MHz signals Indoor comfort indicator Alternate display of temperature and Temperature display in °F/°C humidity display Indoor & outdoor temp w\ MIN/MAX and time of measurement Water-resistant casing Humidi
ページ3に含まれる内容の要旨
after 60 seconds, remove the batteries from both units and wait for 6. Insert the batteries in the third transmitter as soon as the "channel at least 60 seconds before reinserting them. 2" icon and outdoor data are displayed on the Weather Station. Then within 2 minutes, the channel 3 outdoor data from the third 4. The outdoor temperature and humidity data from the first transmitter will be displayed and the channel icon will shift back to transmitter (channel 1) and the signal reception ic
ページ4に含まれる内容の要旨
2. Insert batteries observing the RESET correct polarity (see marking). The Weather Station and the Thermo-hygro transmitter need to be reset 3. Replace compartment cover. when one of the following conditions occur: Unsuccessful 915 MHz signal reception. Malfunction on the units. Battery replacement. To perform a reset, remove all batteries from the units. Wait for at least 1 minute before powering up the Weather station again. Proceed from step 1 in “Setting Up
ページ5に含まれる内容の要旨
OUT/+ key Stop the alarm during alarm ringing Press briefly to toggle between MAX/MIN and current outdoor Stop snooze mode temperature/humidity data ALM/DATE key Increase, change, toggle all values in manual set mode Press and hold key for 3 seconds to enter the alarm set mode Press to set the alarm minute (inside alarm setting mode) Activate/de-activate the alarm time Silence the alarm Silence the alarm Cancel snooze mode Cancel snooze mode Display date
ページ6に含まれる内容の要旨
Note: SET mode is entered by pressing and holding the SET key for 3 The default time zone of the Weather Station is “-5h”. U.S. time zones are seconds. If you do not press any keys for 15 seconds while in SET negative numbers: –5h (EST), -6h (CST), -7h (MST) and –8h (PST).To mode, the Weather Station switches out of SET mode. set a different time zone: 1. The current time zone value starts flashing. LCD CONTRAST SETTING: 2. Use the OUT/+ key to set the time zone. The range runs from 0
ページ7に含まれる内容の要旨
1. The hour digit will start flashing. Month and date 2. Use the OUT/+ key to set the hour. (12hr time format) 3. Press again the SET key to set the minutes. The minute digits start Date and month flashing. (24hr time format) 4. Use the OUT/+ key to set the minutes. Note: When set to 24-hour time, the calendar setting mode will display 5. Confirm with the SET key and enter the Calendar setting. the date to the left of the month. Note: If the WWVB reception function i
ページ8に含まれる内容の要旨
3. Confirm with the SET key and enter the Weather forecast icon TO EXIT THE MANUAL SETTING MODE sensitivity setting. To exit the manual setting mode anytime during the manual setting, press the SNOOZE/CH key or wait for automatic timeout. The mode will return WEATHER FORECASTING ICON SENSITIVITY SETTING: to normal time display. For locations with rapid changes of weather conditions, the weather icons sensitivity can be set to a different level for faster display of weather ALARM SETTIN
ページ9に含まれる内容の要旨
INDOOR RELATIVE HUMIDITY AND INDOOR TEMPERATURE: TOGGLING AND RESETTING THE INDOOR READINGS: The indoor temperature and humidity data and the indoor comfort 1. To toggle between the current indoor and the MAX/MIN indoor indicator are automatically updated and displayed on the second section temperature, and the humidity data and the times (for temperature of the LCD. data only) they were recorded, press the IN key: - Once to show the MAX indoor temperature and humidity MAX icon d
ページ10に含まれる内容の要旨
location as being a possible change in air-pressure when really it is due AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH to the slight change of altitude. BAROMETRIC PRESSURE TREND) The third section of the LCD also shows the relative air pressure value WEATHER TENDENCY INDICATOR and the air pressure history. Working together with the weather icons are the weather tendency indicators (located on the left and right sides of the weather icons). When the indicator points upwards, i
ページ11に含まれる内容の要旨
- Once to show transmitter 2 Battery power may be reduced for the Thermo-hygro transmitter at cold - Twice to show transmitter 3 temperatures. - Three times to return to transmitter 1 CHECKING FOR 915MHz RECEPTION 2. Use OUT/+ key to view the MIN/MAX temperature and humidity If the outdoor temperature and humidity data are not being received data for the selected transmitter. 3. To reset the minimum and maximum temperature and humidity within three minutes after setting up (or outdoor d
ページ12に含まれる内容の要旨
CARE AND MAINTENANCE: Extreme temperatures, vibrations and shocks should be avoided as these may cause damage to the unit and give inaccurate forecasts and readings. When cleaning the display and casings, use a soft damp cloth only. TO WALL MOUNT: Do not use solvents or scouring agents as they may mark the LCD 1. Secure the bracket onto a desired wall using and casings. the screws and plastic anchors. Do not submerge the units in water. Furthermore, fix all parts
ページ13に含まれる内容の要旨
must contact La Crosse Technology, Ltd for problem determination and Your La Crosse Technology, Ltd warranty covers all defects in material service procedures. Warranty service can only be performed by a La and workmanship with the following specified exceptions: (1) damage Crosse Technology, Ltd authorized service center. The original dated bill caused by accident, unreasonable use or neglect (including the lack of of sale must be presented upon request as proof of purchase to La reasonabl