Important Installation Recommendations 1
Tools and Materials Required for Installation 2
Step-by-Step Installation Instructions
— Feed water supply 3
— Electronic faucet installation 4
NSF ®
— Wall mounting 5
— Tubing connection 5
GNUT05Z, GXUT05Z, GNUV10Z,
— Battery installation 5
GXUV10Z, GNUL30Z, and GXUL30Z are
tested and certified
ページ2に含まれる内容の要旨
TOOLS AND MATERIALS REQUIRED FOR INSTALLATION • Slotted and Phillips screw drivers • Pliers and adjustable jaw wrench • Hand or battery powered drill and 1⁄4² bit (saddle valve installation) • Electric drill and a drill bit to drill a 1⁄4² hole (type as required) if a mounting hole is needed for the faucet CAUTION: To avoid damaging the sink, consult a qualified plumber or installer for drilling procedures. Special drill bits may be needed for porcelain or stainless steel. • Contents included w
ページ3に含まれる内容の要旨
STEP-BY-STEP INSTALLATION INSTRUCTIONS FEED WATER SUPPLY Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting. For new home installation using standard plumbing fittings, see Fig. 2A below. A typical installation for existing homes using the saddle valve is shown in Fig. 2B below. Fig. 2A. PREFERRED WATER SUPPLY CONNECTION A. PREFERRED INSTALLATION (using compression fitting) 1. Turn off the cold water supply. 2. Complying with plumbing codes, ins
ページ4に含まれる内容の要旨
ELECTRONIC FAUCET INSTALLATION Nut (2) Fig. 3A. Fig. 3B. Be sure there is room underneath the sink to make the needed TOP VIEW connections. Select one of the following places to install the faucet: Screw (2) Screw (2) —IN an existing sink spray attachment or soap dispenser hole —IN a hole to be drilled in the sink top Faucet —IN a hole to be drilled in the countertop, next to the sink base NOTE: Looking at Fig. 3D, be sure the faucet base will fit flat against the surface at the selected locatio
ページ5に含まれる内容の要旨
Tubing MOUNTING BRACKET TO CABINET WALL Fig. 4 7-9⁄16² connector The bracket can be used as a template for marking the location of the mounting screws. When determining the location of the bracket make sure you leave 1-1⁄2² to 2² of free area under the sumps to allow for sump removal and enough space on either side to make the tubing connections. Mounting MAKE TUBING CONNECTIONS bracket 1. Run the length of 3⁄8² tubing, connected to the bottom of faucet, to the filter Mounting screws system out
ページ6に含まれる内容の要旨
53 68 6
ページ7に含まれる内容の要旨
GENERAL ELECTRIC PARTS CATALOG G G G G G G G N N N X X X X U U U E U U U L T V M L T V 3 0 1 0 3 0 1 0 5 0 1 0 5 0 Z Z Z Z Z Z Z 0 0 0 0 0 0 0 1 1 1 1 1 1 1 REF. NO. PART NO. PART DESCRIPTION 0001 WS02X10001 SCREW #10-14 X 3/4² 8 8 8 8 8 8 8 0002 WS28X10001 BRACKET MOUNTING 1 1 1 1 1 1 1 0003 WS22X10008 NUT 3/8² TUBE 2 2 2 2 2 2 2 0004 WS22X10007 INSERT 3/8² TUBE 2 2 2 2 2 2 2 0005 WS02X10003 SCREW #10-14 X 1/4² 2 2 2 2 2 2 2 0006 WS22X10002 ELBOW 3/8² NPT X 3/8² 2 2 2 2 2 2 2 0007 WS19X10001 HE
ページ8に含まれる内容の要旨
8
ページ9に含まれる内容の要旨
13