HI-FLO 52 ® AUTOMATIC WATER SOFTENERS SPECIFICATIONS AND OPERATING DATA MODELS Model 180 Model 300 Model 450 Model 600 Model 750 Model 900 1 Capacity , grains @ 180,000 300,000 450,000 600,000 750,000 900,000 Maximum pounds 90 150 225 300 375 450 @ Salt Dosage grams @ 11,664 19,440 29,160 38,879 48,599 58,320 kilograms 41 68 102 136 170 204 1 Capacity , grains @ 120,000 200,000 300,000 400,000 500,000 600,000 Minimum pounds 36 60 90 120 150 180 @ Salt Dosage grams @ 7,776 12,960 19,440 25,920 32
ページ6に含まれる内容の要旨
ページ7に含まれる内容の要旨
ページ8に含まれる内容の要旨
ページ9に含まれる内容の要旨
ENGINEER’S SPECIFICATION CUSTOMER: AUTOMATIC WATER SOFTENER HI-FLO 52 ® DATE: 1.0 SCOPE 1.1 Provide as indicated a vertical pressure type water softener system complete with pressure vessel, softening resin, control valve, brine maker and electronic controller. The system will be of an approved design as fabricated by a manufacturer regularly engaged in the production of water treatment equipment. All equipment and material will be supplied in compliance with the specifications as intended for a
ページ10に含まれる内容の要旨
3.2 DESIGN PARAMETERS Normal System Flow & Pressure Drop: gpm @ 15 PSI Maximum System Flow & Pressure Drop: gpm @ 25 PSI Backwash/Rinse Flow: gpm Backwash Volume: gallons nominal Daily Water Usage: gallons per day (gpd) Daily Hours of Water Demand: Operating Temperature Range: 40°–120°F Operating Pressure Range (System): 30–100 PSI Electrical Requirements: 120 Volt, 60 Hz, 1 phase (receptacle required) System Dim
ページ11に含まれる内容の要旨
(Steel vessel) 4.1.4 Tank Finish – Interior Tank interior shall have near white sandblast and be coated to 8 to 10 mil DFT with an epoxy phenolic designed specifically as a high chemical resistant, non toxic, odorless protective coating. The lining shall meet the requirements of the US Federal Register, Food and Drug Regulations, Title 21, Chapter 1, Paragraph 175.300. 4.2 INTERNAL DISTRIBUTION 4.2.1 The upper distribution system shall be of the baffle type to dispense water laterally to avoid
ページ12に含まれる内容の要旨
4.4 CONTROLS A fully integrated programmable micro-processor driven electronic controller shall be provided to automatically cycle the main operating valve through the regeneration sequence. The electronic controller shall be designed and manufactured by the same manufacturer as the water treatment equipment. The controller shall sequence all steps of an automatic regeneration and automatically return the softener to a service or stand-by mode. The initiating time and/or volume setpoints shall a
ページ13に含まれる内容の要旨
(Meter Initiated, Alternating Twin Unit) An operator selected program of immediate volume initiated regeneration for alternating twin configurations shall be available. The controller shall be capable of being programmed in the field without additional interface devices. The controller shall indicate various functions that include time of day, instantaneous flow rate display, volume remaining before next regeneration, number of regenerations in the last fourteen (14) days, the days since the l
ページ14に含まれる内容の要旨
(Meter Initiated systems ONLY) 4.4.3 Flow Sensor(s) (1.5” Plastic Turbine Meter) A flow sensor package shall be provided consisting of an turbine-type Hall Effect; the package shall include a total of _____ flow sensors with fittings. The fitting provided shall be a 1-1/2 inch threaded Noryl housing. A 4-foot length of cable shall be provided for direct connection to the system controller. The flow sensor package provided shall be functional within the flow range of 1 to 60 gpm. The operatin
ページ15に含まれる内容の要旨
valve controls to admit the correct volume of fresh water to the brine tank in accordance with the salt dosage setting on the controls. The brine valve will include a float operated safety shut-off valve as a back up to the timed refill from the main operating valve control to prevent brine tank overflow. 4.7 ACCESSORIES (All Optional selections) 4.7.1 Water test kits for hardness tests will be supplied. 4.7.2 Pressure Gauges for hard water inlet and soft water outlet. 4.7.3 Sampling Cocks