TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION .............................................................................2 2. OPERATION & FUNCTION OF PARTS....................................................................................3, 4 A. Cooling Operation B. Function of Parts 3. LOCATION REQUIREMENTS.......................................................................................................4 4. INSTALLATION PROCEDURES ............................
ページ3に含まれる内容の要旨
4) When using an instrument or replacing a part for repairing, check it is applied to rated voltage current and capacity. 5) Prevent water from flowing into electric elements in mechanical parts. 6) When carrying or tilting the appliance, remove all the objects on it. 7) If the cooling cycle is out of order, contact nearest authorized service center for maintenance, repair and adjustment. 1. SPECIFICATION & PARTS IDENTIFICATION MODEL C12E (CHILLER) DIMENSION 410W×210D×290H(mm) WEIGHT
ページ4に含まれる内容の要旨
2. OPERATION & FUNCTION OF PARTS 4
ページ5に含まれる内容の要旨
A. Cooling Operation The vapor refrigerants that compressed to high temperature & high pressure conditions in the compressor, turn into liquid refrigerant of high temperature and high pressure passing through the condenser, and then turn into the liquid refrigerants of low temperature and low pressure conditions by passing through the capillary tubes. The liquid refrigerant of low temperature & low pressure absorbs the surrounding heat while evaporating in the evaporator. Then, it is suck
ページ6に含まれる内容の要旨
4. INSTALLATION PROCEDURES A. Connect the 1/4”OD tubing between water inlet of chiller and the supply water hose with pressure rating suitable for use with the application. The tubing must be acceptable for use with potable water. B. Using the 1/4”OD tubing included with the (gooseneck) faucet, connect on water outlet of chiller. -Flush water in lines before installing gooseneck faucet. -Acceptable supply water pressure is 15~100 PSI (100~700kPa) CAUTION: TO PREVENT PROPERTY DAMAGE DUE TO
ページ7に含まれる内容の要旨
TROUBLE POSSIBLE CAUSE REMEDY REFRIGERATION SYSTEM No electric power to outlet. Turn on electric power outlet. The thermostat is misadjusted or Adjust or replace the thermostat, as defective. necessary. The wires leading to the thermostat are Check the internal wiring. defective or are not connected. Make repairs as necessary. Check the line voltage. It must be at A. Compressor does The line voltage is low. least 90% of minimum voltage. not run. The compressor over-load Replace the de
ページ8に含まれる内容の要旨
thermostat may be defective. Replace the thermostat. short running cycle. It The thermostat is improperly set for the is cooling, but does not prevailing environmental conditions and Adjust the thermostat. run long enough to cooler usage. The compressor motor is defective, Replace the compressor. cool water to the causing the cooler to cycle on the overload Return cooler to authorized service center required level. protector. or factory for repair. F. A. The cold water The cold water
ページ9に含まれる内容の要旨
9
ページ10に含まれる内容の要旨
10