ページ1に含まれる内容の要旨
MANUF ACTURING
NUMBERS:
9700501
9700505
9700508
9700512
WATER FILTRATION
SYSTEM
Model SE-4200/4400
P/N 1010852 Rev. C 04/06
’
Owner s Manual
ページ2に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM TABLE OF CONTENTS Owner Information .....................................................2 Operation................................................................... 10 General ......................................................................2 Operating Controls (Figure 2) ................................. 10 Warranty Information .................................................2 Programming ...........................................................11
ページ3に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM Purchased From: Service/Technical Assistance If you experience any problems with the installation Date of Purchase: or operation of your unit, contact Antunes Filtration Model No.: Technologies at 1-630-784-1000 or toll free in the United States at 1-800-253-2991. Serial No.: Fill in the information in the next column and have it Mfg. No.: handy when calling for assistance. The serial number is on the specification plate on the unit. IMPORTANT A.J. Antun
ページ4に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM IMPORTANT SAFETY INFORMATION (continued) The following warnings and cautions appear - Do not modify the power supply cord plug. throughout this manual and should be carefully If it does not fit the outlet, have a proper observed. outlet installed by a qualified electrician. • Turn the unit off, disconnect the power - Do not use an extension cord with this appliance. source, and allow unit to cool down before performing any service or maintenance on the
ページ5に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM SPECIFICATIONS Electrical Ratings WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO Model & Voltage Watts Amps Hertz FOLLOW THE INSTRUCTIONS IN THIS MANUAL Mfg. # COULD RESULT IN SERIOUS INJURY OR DEATH. SE-4200 120 150 1.25 50/60 • Electrical ground is required on this appliance. 9700501 & 9700505 • Do not modify the power supply cord plug. If SE-4400 230 150 .75 50/60 it does not fit the outlet, have a proper outlet 9700508 & installed by a qualified ele
ページ6に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM SPECIFICATIONS (continued) Dimensions A B Control Box Drain Permeate (use water) C Inlet P/N 1010852 Rev. C 04/06 6
ページ7に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM INSTALLATION When making a plumbing connection to the system, Unpacking remember to use a back-up wrench on the support The carton should contain the filtration system and an plumbing. Always use a good quality and approved information packet. pipe sealant or Teflon tape on pipe threads. • SE-4200 or SE-4400 Be careful not to get the pipe sealant inside the pipe • Information Packet when making the connections. Do not over tighten the connections
ページ8に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM INSTALLATION (continued) be installed in the water line after the permeate connec- Locating and Mounting the system tion. This will help prevent possible contamination of Consider these points before mounting the system: the filter system due to other equipment downstream. The check valve (not supplied) should be mounted • Note the location of the water supply, drain, and close to the system outlet, and sized properly for the an appropriate electrical
ページ9に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM INSTALLATION (continued) FLUSHING AND STARTING THE SYSTEM SANITIZING THE SYSTEM AND LINES To ensure that the highest quality water is produced The plumbing must also be sanitized to eliminate pos- from the system, the plumbing leading from the filter sible contamination that may have occurred during the system must be flushed clear of all debris after the installation process. Chlorine bleach can be used to system is hooked up. After making the connection
ページ10に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM OPERATION Filtration Process Operating Controls (Figure 2) The filtration process includes a Filtration Cycle and a Backwash Cycle. Control Function Button During the Filtration Cycle, water enters the system inlet port and passes through the filter elements before FLUSH Performs a QUICK FLUSH operation exiting via the Permeate outlet. when actuated during FILTER MODE or STOP MODE. This system is designed so that no valves are powered RUN Initializes
ページ11に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM OPERATION (continued) Using the Up and Down arrow buttons, enter the Programming correct date in mm/dd/yy format. After each entry, 1. Once the system is connected to a power source, press the Enter button. For example, for June, set the unit displays the following messages in the the month as 06 and then press the Enter button. table below in order: Set the date and year in this same manner. Message Description 5 The system then displays the SET T
ページ12に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM OPERATION (continued) SET QUICKFLUSH MODE SET FLUSH CYCLE MODE 1. From the FILTER MODE display, press the Stop NOTE: The Quick Flush function allows the sys- button. The system switches to STOP MODE and tem to be used for water systems containing a displays the STOP MODE display. high quantity of air. Air does not pass through the filtration membranes. Performing a quick flush 2. Press the Menu button. at pre-set times allows the accumulated air to
ページ13に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM OPERATION (continued) RESET DEFAULTS MODE 7. The system displays the FLUSH BY PRESS DIFF display. If the filtration system came with pressure 1. From the FILTER MODE display, press the Stop transducers installed, this feature is available. button. The system displays the STOP MODE dis- If no transducers are installed, this feature is play. ignored. The default value is on. This should be 2. Press the Menu button. appropriate for most locations.
ページ14に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM OPERATION (continued) NOTE: The REVIEW HISTORY mode displays infor- 5. The system displays the SET ENABLE PASSWORD mation about the most recent operation first. display. The default setting is off. If you do not want to use a password, press the Enter but- 5. When finished reviewing history, press the Enter ton. The system will then display the SELECT button. The system will display the REVIEW OF LANGUAGE display. The default setting is English
ページ15に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM OPERATION (continued) Operating the Unit WARNING Once a password has been activated, that pass- After all of the menus have been programed, the sys- word will be required to change any settings. DO tem can be activated. NOT lose your password! Keep it in a safe place. 1. To start the filtration operation, press the RUN Contact the manufacturer if you have lost your button. The system will perform a BORE AIR password. RELEASE function and return to FILT
ページ16に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM MAINTENANCE The SE-4200/4400 Filtration system is designed to 6. Inset the new cartridge into the system require very little maintenance. To ensure that the 7. Attach the Permeate Port connection to the new water is of the highest quality, occasionally some ser- cartridge. vice is required. 8. Inspect the O-rings to make sure they are clean Checking the Controller Program and are not splitting or cut. For all O-rings, make sure they are lubricated w
ページ17に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM TROUBLESHOOTING Problem Possible Cause Corrective Action Unit does not have power. The power cord is not correctly plugged Plug power cord in correctly. in. The Control Display is The power cord is not correctly plugged Plug power cord in correctly. blank. in. Control Board is inoperable. Contact your maintenance person or Authorized Service agency. Transformer is inoperable. No water comes out of the Unit in “STOP” mode Set unit to “RUN” mode. filter system
ページ18に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM TROUBLESHOOTING (continued) Problem Possible Cause Corrective Action Water leaks from Permeate Port not tight. Tighten with strap wrench if necessary. Permeate Port. O-rings not lubricated. Lubricate O-rings with food-grade lubricant. O-rings split, cut, or twisted. Replace O-rings. Water leaks from system Not enough pipe thread sealant used. Redo fitting with proper amount of sealant. fitting or connection. Fitting loose or broken. Retighten or replace fitti
ページ19に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM REPLACEMENT PARTS - SE-4200/4400 22 22a 21 25 47 26 23 28 29 65 30 See Inset A 33 47a 47 34 36 32 35 37 48 31 38 40 39 41 42 43 8 Inset A 45 1 9 10 12 13 11 14 2 16 15 18 17 5 20 P/N 1010852 Rev. C 04/06 19
ページ20に含まれる内容の要旨
SE-4200/4400 WATER FILTRATION SYSTEM REPLACEMENT PARTS - SE-4200/4400 (continued) Item Part Description Qty. Item Part Description Qty. No. No. 34 2190141 Union Adaptor 3/4” 2 1 1001073 Label Control Panel 1 2 5550100 Enclosure Control-upper 1 35 2190124 Nipple 3/4” Npt 6 5 7000434 SE Series 3 Board Controller 1 36 0504007 Clamp Permeate 1 Replacement Kit 37 2190126 90° Elbow 3/4” Npt 2 6* 304P113 Screw, FLTHD #4-40 x 1 15/16” 4 38 0504006 Bracket Permeate 1 8* 308P151 Sems Screw #8-32