ページ1に含まれる内容の要旨
Dampers, Actuators and Valves
control your environment with honeywell
DAmPS, er v AveS l AnD ActuA torS
Application And Selection Guide
ページ2に含まれる内容の要旨
How to use this guide Additional product information All pages in this literature are constructed in one of two ways: t o find more detailed information on the individual products included in this document, go to: http://customer.honeywell.com For unassembled product: and use the search text box to quickly locate product specific As a reference, pictures will represent the valves and actuators content. separately; and part numbers are highlighted in blue. t o order a complete product one
ページ3に含まれる内容の要旨
Table Of COnTenTs Resilient seat butterfly Valves Section 1: DCa & Damper selection 2-Way electrically-actuated Control ......................................66 Dampers ......................................................................................8 3-Way electrically-actuated Control ......................................68 DCa ...........................................................................................12 2-Way Pneumatically-actuated Control ...........................
ページ4に含まれる内容の要旨
Table Of COnTenTs flanged Cage Valve Section 3: submittal sheets (COnT.) V5051a ...............................................................................139 MP958 ................................................................................104 flanged Globe Valve Modutrol IV Motor V5011a, b ..........................................................................140 M4185; M8185 ...................................................................105 V5013b, C ......................
ページ5に含まれる内容の要旨
Table Of COnTenTs Pneumatic Valve actuator Parts and accessories ....................196 foot Mounted Motor accessories ............................................198 Damper and Valve linkage accessories ...................................200 Section 8: Competitive Cross Reference Direct Coupled actuator ...........................................................202 Control ball Valve 2-Way Valve .......................................................................220 2-Way Valve + non-spr
ページ6に含まれる内容の要旨
6
ページ7に含まれる内容の要旨
Selection GUiDe Section 1: DCa & Damper selection Dampers ......................................................................................8 DCa ...........................................................................................12 fire and smoke ..........................................................................14 7
ページ8に含まれる内容の要旨
Damper and actuator sizing Use the following guidelines to determine the actuator quantity and Determining Damper Actuator torque torque requirements for your damper configuration. Requirements Determine Damper Actuator locations Use the following procedure to determine the required torque for your damper. Use the following configuration to determine the amount of actuator locations your damper will require. nOTe: Damper area is measured using the H and W dimensions. single section ≤ 48 x 7
ページ9に含まれる内容の要旨
DcA & DAMpeR Selection Damper and actuator sizing Table 2. approximate industry standard damper lb-in. per sq ft value. Face Velocity (fpm)/ Static Pressure (in. wc Leakage Damper 500/ 1000/ 1500/ 2000/ 2500/ Blades 1 2 3 4 5 Low Parallel 4 7 10.5 12 14 Low Opposed 3 5 7.5 8.5 10 Standard Parallel 3 4.5 6.5 7 8 Standard Opposed 2 3 4.5 5 6 Damper Sizing Dampers can be sized using two different methods; actual sizing and nominal sizing. When actual sizing is used the damper dimensions will
ページ10に含まれる内容の要旨
Damper and actuator sizing HVAC performance depends largely upon airflow, and Honeywell Volume Control Dampers are built for both improved airflow and heavy-duty use. Honeywell has long been the leading source for airflow control, with Volume Control Dampers that meet AMCA-certified Air Performance Standards, the highest established standards for commercial control dampers. Designed to minimize leakage, Honeywell dampers will give you efficient, trouble-free operation for years to come. Stan
ページ11に含まれる内容の要旨
DcA & DAMpeR Selection Damper and actuator sizing Standard Round Dampers Custom Dampers D690 and DM7600 Round Dampers. The 6” to 16” round dampers Need a custom damper? Contact the Take-Off Service. Below is a are used in zoning systems to control airflow in a round duct. These sample list of the products we frequently quote. dampers come with neoprene and silicone seals for tight close off Custom Rectangular Dampers and low leakage. The DM7600 includes an actuator that is already attached to
ページ12に含まれる内容の要旨
Direct Coupled actuators DIReCT COUPleD aCTUa TORs QUICK seleCTIOn GUIDe Precise, reliable performance. lasting value. e ase Improve Installation Time of installation. everything you look for in direct- • Self-centering shaft adapter provides mounting coupled actuators hinges on quality. and quality flexibility and greater clamping force. engineering is what makes Honeywell’s complete • C o m m o n w i r i n g a m o n g f a m i l i e s f o r e v e r y s i g n a l lin
ページ13に含まれる内容の要旨
DcA Selection Direct Coupled actuators sPRInG ReTURn Running time power Supply control input/output Auxiliary Knob Adj. Internal Order Approximate Spring 0/2-10 3 kOhm Feedback Zero SPDT Minimum Specification Area of Damper Drive Return 24 120-230 VA Rating Vdc, NTC, (0/2-10 and Auxiliary Position Number (4.5 lb-in/sq. ft.) (seconds) (seconds) Vac/dc Vac (Running) On/Off Floating 3-Position Vdc) Span Switches Potentiometer S03 Series (3 Nm, 27 lb-in) MS8103A1030 6 45 <25 • • 0 MS8103A113
ページ14に含まれる内容の要旨
fire & smoke actuators Key Features and Benefits Honeywell’s complete line of two-position, fast-acting spring- return actuators meet all of your needs for fire and smoke control • Integral spring r etur n that ensur es the pr oper level of tor que applications. all models are designed to meet the Ul-555 and • P a t e n t e d d e s i g n t h a t e l i m i n a t e d l i m i t s w i t c h e s , r e d u c i n g p o w e r Ul-555s high temperature requirements for fire
ページ15に含まれる内容の要旨
Val Ve Selection Section 2: Valve Selection Control Valve Applications .........................................................17 Threaded and Flanged Globe Valves 2”-3” Control Valve Selection Criteria ..................................................18 With Tandem Linked Direct Coupled Actuators ....................46 2-Way ...................................................................................18 Flanged Globe Valves 2 ½ - 3” 3-Way .........................................
ページ16に含まれる内容の要旨
16
ページ17に含まれる内容の要旨
Val Ve Selection Control Valve Applications Control Valve Applications 17 Fan Coil/Zone Valve
ページ18に含まれる内容の要旨
Control Valve Selection Criteria 2-Way Unitary Globe Cartridge Cartridge Fan Coil Threaded Flanged Cage Globe Attribute Specification VU52 VU53 VCzA/B V58x2 V5011N... V5011F V5011G V5011A V5011B VGF2xS 1/2" [DN15] • • • • • 3/4" [DN20] • • • • • 1" [DN25] • • • • 1 1/4" [DN32] • • 1 1/2" [DN40] • 2" [DN50] • Pipe Size 2 1/2" [DN65] • • • • 3" [DN80] • • • • 4" [DN100] • • • 5" [DN125] • • • 6" [DN150] • • • Other (maximum size) Sweat • • • • NPT Internal Thread • • • • • • • Pipe
ページ19に含まれる内容の要旨
Val Ve Selection Control Valve Selection Criteria 2-Way Globe Control Ball Butterfly Pressure-Balanced Threaded Flanged Resilient Seat Attribute Specification V5862A3 VGF2xP VBN2 VBF2 VFF1 VFF2 1/2" [DN15] • 3/4" [DN20] • 1" [DN25] • • 1 1/4" [DN32] • • 1 1/2" [DN40] • • 2" [DN50] • • • Pipe Size 2 1/2" [DN65] • • • • 3" [DN80] • • • • 4" [DN100] • • • • 5" [DN125] • • • • 6" [DN150] • • • • Other (maximum size) 20" [DN500] Sweat NPT Internal Thread • • Pipe Fittings Inverted Flare
ページ20に含まれる内容の要旨
Control Valve Selection Criteria 3-Way Unitary Globe Cartridge Fan Coil Cartridge Globe Threaded Flanged Cage Attribute Specification VU54 VCzM/N V58x3 V5863A3 V5013N... V5013B V5013C VGF3xLD VGF3xEM 1/2" [DN15] • • • • 3/4" [DN20] • • • • 1" [DN25] • • • • 1 1/4" [DN32] • • • 1 1/2" [DN40] • • 2" [DN50] • Pipe Size 2 1/2" [DN65] • • • 3" [DN80] • • • 4" [DN100] • • • • 5" [DN125] • • • • 6" [DN150] • • • • Other (maximum size) Sweat • • • NPT Internal Thread • • • • • Pipe Fittin