! ! WARNING WARNING TO REDUCE THE RISK OF INJURY TO PERSONS TO REDUCE THE RISK OF FIRE, ELECTRIC IN THE EVENT OF A RANGE TOP GREASE SHOCK OR INJURY TO PERSONS, OBSERVE FIRE, OBSERVE THE FOLLOWING*: THE FOLLOWING: 1. SMOTHER FLAMES with a close-fitting lid, cookie 1. Use this unit only in the manner intended by the sheet or metal tray, then turn off the burner. manufacturer. If you have questions, contact the BE CAREFUL TO PREVENT BURNS. IF THE manufacturer at the address or telephone number
ページ3に含まれる内容の要旨
- E60000 SERIES RANGE HOOD SYSTEM - INTERNAL BLOWERS MODEL 441 MODEL 647 MODEL 634 OR 644 MODEL 643 MODEL 437 (10’’ ROUND WALL CAP) (7” ROUND WALL CAP) (ROOF CAP) (8” ROUND WALL CAP) (HIGH CAPACITY ROOF CAP) MODEL 418 8” ROUND MODEL 415 ADJUSTABLE (10” ROUND 7” ROUND ADJUSTABLE MODEL 421 ELBOW ADJUSTABLE ELBOW) ELBOW (10” ROUND VERTICAL IN-LINE DAMPER) MODEL 407 8” ROUND (7” ROUND STANDARD —2 FT. SECTIONS) DUCT MODEL 410 (10” ROUND DUCT MODEL 412 MODEL 413 —2 FT. SECTIONS) TRANSITION TRANSI
ページ4に含まれる内容の要旨
- E60000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLOWERS MODEL 441 MODEL 437 MODEL HLB9 (800 CFM) (10” ROUND WALL CAP) (HIGH CAPACITY ROOF CAP) OR HLB11 (1100 CFM) IN-LINE BLOWER MODEL 335 (1200 CFM) (INCLUDES TWO 8” X 12” TO MODEL 331H (600 CFM) OR 336 (1500 CFM) 10’’ ROUND TRANSITIONS) OR 332H (900 CFM) EXTERIOR BLOWER EXTERIOR BLOWER MODEL 441 MODEL 643 (10” ROUND (8” ROUND WALL CAP) WALL CAP) MODEL HLB6 (600 CFM) IN-LINE BLOWER (INCLUDES TWO 4½” X 18½” TO 10’’ ROUND TRANSITIONS) MODE
ページ5に含まれる内容の要旨
1. SELECT BLOWER OPTION AND INSTALLATION TYPE 1.1 NON-DUCTED INSTALLATION For a non-ducted installation, a recirculation kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness, we recommend installing this kit with a single (internal) blower hood. The kit fits hood from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKE60 Series. 1.2 DUCTED INSTALLATION The Broan Elite E60000 Series range hood includes many configuratio
ページ6に含まれる内容の要旨
2. MEASURE INSTALLATION Dimensions for the most common installation are illustrated beside. Ceiling Cabinet, soffit, The minimum hood distance above cooktop must not be less Top of wood decorative flue or A mounting strip than 24’’. A maximum of 30” above cooktop is highly non-duct kit flue A + 2’’ recommended for best capture of cooking impurities. Distances over 30” are at the installer and users discretion. Hood Minimum distance between the hood and cooktop: 24’’ Recommended maximum dista
ページ7に含まれる内容の要旨
3. PREPARE THE INSTALLATION (CONT’D) DUCTED INSTALLATIONS ONLY Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (vertical or horizontal). INTERNAL DOUBLE BLOWER HOOD INTERNAL SINGLE BLOWER HOOD VERTICAL DISCHARGE CABINET BOTTOM VIEW CABINET BOTTOM VIEW HOOD C C
ページ8に含まれる内容の要旨
5. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY) Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below. VERTICAL DISCHARGE 1 2 3 1 2 3 HORIZONTAL DISCHARGE NOTE: For ducted installation only. HR0021 A B Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood. Install the wire clamp (included in parts bag). NOTE: For a non-ducted installation, punch out the back electrical knock-out (
ページ9に含まれる内容の要旨
8. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) HOOD ONLY) All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the inner back panel of the hood. The procedure below applies for one or two blowers. LEFT SIDE MOUNTING SCREW LOCATION Using a 5/16” socket, remove all blower mounting screws from the inner top of t
ページ10に含まれる内容の要旨
9. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE) (INTERNAL BLOWER(S) HOOD ONLY) Using standard 3/8’’ screws provided, secure the adapter to the top (or back) of the hood (2 screws for a 3¼” x 10” adapter/damper and 4 screws for a 4½” x 18½” adapter). Seal the adapter to the hood using duct tape. For round ducting, install an appropriate sized transition and seal the joints with duct tape. HJ0013 10. INSTALL WOOD MOUNTING STRIP Measure and mark a level line on wall above cooktop location fo
ページ11に含まれる内容の要旨
13. INSTALL THE HOOD CAUTION Hold the hood until it is completely secured to the wood mounting strip. MOUNTING SCREWS LOCATION INTERNAL BLOWER(S) ONLY Run power cable to installation location. Remove the electrical compartment cover. Insert the cable in the hood and tighten the wire clamp to secure the cable. ALL INSTALLATIONS HD0264 Rest the back cavity of the hood on the wood mounting strip. WALL ANCHORS LOCATION Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4’’ (for 30’’ a
ページ12に含まれる内容の要旨
16. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER) Refer to instructions included with blower. Plug the 3-prong plug cord from rough-in plate to the 3-prong male connector inside the hood (A) and the 2-prong male connector cord from rough-in plate to the 2-prong plug inside the hood (B). B A ! WARNING Do not plug the 2 cords together. HE0078 17. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS Reinstall grease drip rail. The illustration beside shows how to reinsert the grease drip rail into the
ページ13に含まれる内容の要旨
19. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe. Allow filters to dry completely before reinstalling them in the hood. Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of
ページ14に含まれる内容の要旨
20. OPERATION (CONT’D) 4 3 2 1 A B HC0034 A) Halogen light knob B) Blower speed control knob HC0035 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blower switch 4) Blower speed control knob COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity). BLOWER The blower is operated using two controls. Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the
ページ15に含まれる内容の要旨
22. WIRING DIAGRAMS Broan Elite E60000 Series NEON Internal blower(s) hoods BLK FAN SPEED SWITCH CONTROL On 3 1 BLK BRN Off 2 BLU ORA USE ONLY WITH M BLK ORA APPROPRIATE RED WHT MAKE-UP AIR SYSTEM BLK ORA HS THERMOSTAT BLU LINE BLK BLU NEUTRAL WHT GROUND BRN BLU WHT WHT BLK M BLK LAMP RED SWITCH BLK YEL YEL L 1-3 YEL 2 WHT WHT WHT COLOR CODE BLK BLACK BLU BLUE BRN BROWN ORA ORANGE RED RED WHT WHITE LAMP LAMP LAMP YEL YELLOW HE0090A NEON Broan Elite E60000 Series Exterior or In-Line
ページ16に含まれる内容の要旨
23. SERVICE PARTS Broan Elite E60000 Series Broan Elite E60000 Series 1 Exterior or In-Line blower hoods Internal blower hoods 15 15 2 2 3 14 14 3 6 6 5 5 18 4 7 7 17 4 10 9 16 8 11 11 13 13 12 12 HL0105 HL0106 KEY PART DESCRIPTION QTY. (HOOD WIDTH) KEY PART DESCRIPTION QTY. (HOOD WIDTH) NO.NO. 30” 36” 42” 48” NO.NO. 30” 36” 42” 48” ADAPTER/DAMPER 3¼” X 10” 2 SV06750 BROAN ELITE LOGO 11 1 1 SV13296 11 1 1 1(1-BLOWER HOOD) 3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y 22 3 3 SV17797 ADAPTER 4½” X 18½