ページ1に含まれる内容の要旨
www.zephyronline.com
Layers Wall Surface Wall
ALA - M90ABX ASU - M90ASX
ALA - M90AWX ASU - E42ASX
ALA - E42ABX
ALA - E42AWX
Edge Wall Duo Wall
AED - M90ASX ADU - M90ASX
RANGE HOOD - Installation instructions
ページ2に含まれる内容の要旨
www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 27 CAMPANA EXTRACTORA - Manual de utilización...Pag. 53 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 79 - 2 -
ページ3に含まれる内容の要旨
SAFETY INSTRUCTIONS..................................................................................................pag. 4 LIST OF MATERIALS...........................................................................................................pag. 7 DUCTING CALCULATION SHEETS.............................................................................pag. 11 HOOD SPECIFICATION..................................................................................................pag. 12 INSTALLATI
ページ4に含まれる内容の要旨
www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents. Suitable for use in household cooking area WARNING - To reduce the
ページ5に含まれる内容の要旨
settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, fi lters and grease laden surface clean. F. Use high range setting on range only when necessary.Heat oil slowly on low to medium settin
ページ6に含まれる内容の要旨
www.zephyronline.com through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducte
ページ7に含まれる内容の要旨
Models: ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWX Duct Cover Bracket Duct Covers Blower Housing Electrical Junction Box Glass Range Hood Body Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° M4 1 + 1 A B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 1/4" x 2-3/4" 6 D - 7 - List of Materials
ページ8に含まれる内容の要旨
www.zephyronline.com Models: ASU-M90ASX / ASU-E42ASX Duct Cover Bracket Duct Covers Electrical Junction Box Blower Housing Control Glass Range Hood Light Bulbs Body Decorative Mesh Filters TYPE DESCRIPTION N° M4 1 + 1 A B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 1/4" x 2-3/4" 6 D - 8 - List of Materials
ページ9に含まれる内容の要旨
Models: AED M90ASX Duct Covers Duct Cover Bracket Control Range Hood Body Light Panel Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° M4 1 + 1 A B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 1/4" x 2-3/4" 6 D - 9 - List of Materials
ページ10に含まれる内容の要旨
www.zephyronline.com Model: ADU-M90ASX Duct Cover Bracket Duct Covers Electrical Junction Box Control Blower Housing Range Hood Body Light Panel Light Bulbs Decorative Mesh Filters TYPE DESCRIPTION N° M4 1 + 1 A B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 1/4" x 2-3/4" 6 D - 10 - List of Materials
ページ11に含まれる内容の要旨
Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 11 - Ducting Calculation Sheet
ページ12に含まれる内容の要旨
www.zephyronline.com Models: ALA-M90ABX / ALA-M90AWX / ALA-E42ABX / ALA-E42AWX front of hood side of hood top of hood - 12 - Hood Specifi cations
ページ13に含まれる内容の要旨
Models: ASU-M90ASX / ASU-E42ASX front of hood side of hood top of hood - 13 - Hood Specifi cations
ページ14に含まれる内容の要旨
www.zephyronline.com Models: AED-M90ASX side of hood front of hood top of hood - 14 - Hood Specifi cations
ページ15に含まれる内容の要旨
Models: ADU-M90ASX side of hood front of hood top of hood - 15 -
Hood Specifi cations
ページ16に含まれる内容の要旨
www.zephyronline.com The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this range- hood only with internal blower models MT-020 provided with the kit cod CBI-600A. For external and in-line blower prepa- ration please turn to page 18. 1.Remove the 6” round metal knockout plate from the blower plate by using a fl at head screwdriver. See.Fig.1 2. Remove the (6) screws securing the blower plate to the blower hou
ページ17に含まれる内容の要旨
6. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex connector located inside the blower housing. See Fig.6 7. Install blower and blower plate into blower housing by following the reverse instructions from step 2 then use the screws provided to complete installa- tion. (Tot. 14 type B). See Fig.7 8. Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor wire. See Fig.8 WARNING! Place electrical wiring inside the m
ページ18に含まれる内容の要旨
www.zephyronline.com The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 16. 1. Remove the (6) screws securing the blower pla- te to the blower housing and remove blower plate. See.Fig.1 2. Detach rectangular metal plate from blower pla
ページ19に含まれる内容の要旨
6. Insert the 6 pin female molex connector into the junction box. See Fig. 6A. Secure remote blower junction box to top of blower housing using (2) screws. See Fig. 6B 7. Feed remote blower wire harness through remote blower junction box cover and Connect the wires with those inside the junction box. See Fig. 7 Note: Carry out the power supplly con- nection in accordance with the natio- nal electric code, ANSI/NFPA 70-1999. 8.Secure cover to junction box using (2) screws. Note1: A cable l
ページ20に含まれる内容の要旨
www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certif ed Silver Tape or Duct Tape. Some Ducting Options - 20 - Installation - Ducting Options